Effects of S-Shaped Intake on Aeromechanical Characteristics of a Transonic Fan

2021 ◽  
Author(s):  
Yun Zheng ◽  
Kang Xu ◽  
Hui Yang ◽  
Qingzhe Gao ◽  
Xiubo Jin
Keyword(s):  
1983 ◽  
Vol 105 (1) ◽  
pp. 125-129
Author(s):  
Baoshi Chen ◽  
Tianyi Zhang

Test results obtained from a two-stage fan are analysed and the reasons that caused the design performance target not to be attained are presented in this paper. Addition of a partspan shroud on rotor 1 caused higher losses and changed radial distribution of parameters. Modification on the flowpath and chord length of stator 1 resulted in excessively high inlet Mach number and flow separation in the hub region. The high load and high incidence at the hub of rotor 2 caused higher losses and reduced stall margin of the fan.


Author(s):  
A. J. Gannon ◽  
G. V. Hobson ◽  
R. P. Shreeve ◽  
I. J. Villescas

High-speed pressure measurements of a transonic compressor rotor-stator stage and rotor-only configuration during stall and surge are presented. Rotational speed data showed the difference between the rotor-only case and rotor-stator stage. The rotor-only case stalled and remained stalled until the control throttle was opened. In the rotor-stator stage the compressor surged entering a cyclical stalling and then un-stalling pattern. An array of pressure probes was mounted in the case wall over the rotor for both configurations of the machine. The fast response probes were sampled at 196 608 Hz as the rotor was driven into stall. Inspection of the raw data signal allowed the size and speed of the stall cell during its growth to be investigated. Post-processing of the simultaneous signals of the casing pressure showed the development of the stall cell from the point of inception and allowed the structure of the stall cell to be viewed.


2006 ◽  
Author(s):  
Peng Sun ◽  
Guotal Feng

A time-accurate three-dimensional Navier-Stokes solver of the unsteady flow field in a transonic fan was carried out using "Fluent-parallel" in a parallel supercomputer. The numerical simulation focused on a transonic fan with inlet square wave total pressure distortion and the analysis of result consisted of three aspects. The first was about inlet parameters redistribution and outlet total temperature distortion induced by inlet total pressure distortion. The pattern and causation of flow loss caused by pressure distortion in rotor were analyzed secondly. It was found that the influence of distortion was different at different radial positions. In hub area, transportation-loss and mixing-loss were the main loss patterns. Distortion not only complicated them but enhanced them. Especially in stator, inlet total pressure distortion induced large-scale vortex, which produced backflow and increased the loss. While in casing area, distortion changed the format of shock wave and increased the shock loss. Finally, the format of shock wave and the hysteresis of rotor to distortion were analyzed in detail.


2009 ◽  
Vol 22 (4) ◽  
pp. 364-370 ◽  
Author(s):  
Chen Fu ◽  
Li Shaobin ◽  
Su Jiexian ◽  
Wang Zhongqi

2021 ◽  
Author(s):  
Yaozhi Lu ◽  
Bharat Lad ◽  
Mehdi Vahdati
Keyword(s):  

Author(s):  
Demetrios Lefas ◽  
Robert J. Miller

Abstract Every supersonic fan or compressor blade row has a streamtube, the ‘sonic streamtube’, which operates with a blade relative inlet Mach number of one. A key parameter in the design of the ‘sonic streamtube’ is the area ratio between the blade throat area and upstream passage area, Athroat/Ainlet. In this paper, it is shown that one unique value exists for this area ratio. If the area ratio differs, even slightly, from this unique value then the blade either chokes or has its suction surface boundary layer separated due to a strong shock. It is therefore surprising that in practice designers have relatively little problem designing blade sections with an inlet relative Mach number close to unity. This paper shows that this occurs due to a physical mechanism known as ‘transonic relief’. If a designer makes a mistake, and designs a blade with a ‘sonic streamtube’ which has the wrong area ratio, then ‘transonic relief’, will self-adjust the spanwise streamtube height automatically moving it towards the unique optimal area ratio, correcting for the designer’s error. Furthermore, as the blade incidence changes, the spanwise streamtube height self-adjusts, moving the area ratio towards its unique optimal value. Without ‘transonic relief’, supersonic and transonic fan and compressor design would be impossible. The paper develops a simple model which allows ‘transonic relief’ to be decoupled from other mechanisms, and to be systematically studied. The physical mechanism on which it is based is thus determined and its implications for blade design and manufacturing discussed.


Sign in / Sign up

Export Citation Format

Share Document