Influence of Coolant Density on Turbine Blade Film Cooling at Transonic Cascade Flow Conditions Using the Pressure Sensitive Paint Technique

2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.

Author(s):  
Izhar Ullah ◽  
Sulaiman Alsaleem ◽  
Lesley Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade's leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint measurement technique. In addition, detailed film cooling effectiveness and over-tip flow leakage is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip.


2005 ◽  
Vol 127 (5) ◽  
pp. 521-530 ◽  
Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film-cooling holes, and the tip-gap clearance on the film-cooling effectiveness were studied and compared to those for a plane (flat) tip. The film-cooling effectiveness distributions were measured on the blade tip using the pressure-sensitive paint technique. Air and nitrogen gas were used as the film-cooling gases, and the oxygen concentration distribution for each case was measured. The film-cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film-cooling holes were located (a) along the camber line on the tip or (b) along the tip of the pressure side. The average blowing ratio of the cooling gas was 0.5, 1.0, and 2.0. Tests were conducted with a stationary, five-bladed linear cascade in a blow-down facility. The free-stream Reynolds number, based on the axial chord length and the exit velocity, was 1,138,000, and the inlet and the exit Mach numbers were 0.25 and 0.6, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip-gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film-cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness, with film-cooling effectiveness increasing with increasing blowing ratio.


Author(s):  
Shantanu Mhetras ◽  
Huitao Yang ◽  
Zhihong Gao ◽  
Je-Chin Han

Effects of shaped holes on the tip pressure side, coolant jet impingement on the pressure side squealer rim from tip holes and varying blowing ratios for a squealer blade tip were examined on film-cooling effectiveness. The film-cooling effectiveness distributions were measured on the blade tip, near tip pressure side and the inner pressure side rim wall using Pressure Sensitive Paint technique. Air and nitrogen gas were used as the film cooling gases and the oxygen concentration distribution for each case was measured. The film cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. The internal coolant-supply passages of the squealer tipped blade were modeled similar to those in the GE-E3 rotor blade with two separate serpentine loops supplying coolant to the film cooling holes. A row of compound angled cylindrical film cooling holes was arranged along the camber line on the tip and another row of compound angled shaped film cooling holes was arranged along the span of the pressure side just below the tip. The average blowing ratio of the cooling gas was controlled to be 0.5, 1.0 and 2.0. Tests were conducted in a five-bladed linear cascade in a blow down facility with a tip gap clearance of 1.5%. The free stream Reynolds number, based on the axial chord length and the exit velocity, was 1,138,000 and the inlet and the exit Mach number were 0.25 and 0.6, respectively. Turbulence intensity level at the cascade inlet was 9.7%. Numerical predictions were also performed using Fluent to simulate the experiment at the same inlet flow conditions. Predictions for film cooling are presented. Results show a good correlation between experimental and predicted data. The shape and location of the film cooling holes along with varying blowing ratios can have significant effects on film-cooling performance.


Author(s):  
Manuel Wilhelm ◽  
Heinz-Peter Schiffer

Rotor tip film cooling is investigated at the Large Scale Turbine Rig, which is a 1.5-stage axial turbine rig operating at low speeds. Using pressure sensitive paint, the film cooling effectiveness η at a squealer-type blade tip with cylindrical pressure-side film cooling holes is obtained. The effect of turbine inlet swirl on η is examined in comparison to an axial inflow baseline case. Coolant-to-mainstream injection ratios are varied between 0.45% and 1.74% for an engine-realistic coolant-to-mainstream density ratio of 1.5. It is shown that inlet swirl causes a reduction in η for low injection ratios by up to 26%, with the trailing edge being especially susceptible to swirl. For injection ratios greater than 0.93%, however, η is increased by up to 11% for swirling inflow, while for axial inflow a further increase in coolant injection does not transfer into a gain in η .


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke-wheel wake generator) on the modeled rotor blade is studied using the pressure sensitive paint (PSP) mass-transfer analogy method. Emphasis of the current study is on the midspan region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film-cooling holes. The blade also has radial shower-head leading edge film-cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side and 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film-cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Nian Wang ◽  
Mingjie Zhang ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

This study investigates the effects of blowing ratio, density ratio, and spanwise pitch on the flat plate film cooling from two rows of compound angled cylindrical holes. Two arrangements of two-row compound angled cylindrical holes are tested: (a) the first row and the second row are oriented in staggered and same compound angled direction (β = +45 deg for the first row and +45 deg for the second row); (b) the first row and the second row are oriented in inline and opposite direction (β = +45 deg for the first row and −45 deg for the second row). The cooling hole is 4 mm in diameter with an inclined angle of 30 deg. The streamwise row-to-row spacing is fixed at 3d, and the spanwise hole-to-hole (p) is varying from 4d, 6d to 8d for both designs. The film cooling effectiveness measurements were performed in a low-speed wind tunnel in which the turbulence intensity is kept at 6%. There are 36 cases for each design including four blowing ratios (M = 0.5, 1.0, 1.5, and 2.0), three density ratios (DR = 1.0, 1.5, and 2.0), and three hole-to-hole spacing (p/d = 4, 6, and 8). The detailed film cooling effectiveness distributions were obtained by using the steady-state pressure-sensitive paint (PSP) technique. The spanwise-averaged cooling effectiveness are compared over the range of flow parameters. Some interesting observations are discovered including blowing ratio effect strongly depending on geometric design; staggered arrangement of the hole with same orientation does not yield better effectiveness at higher blowing ratio. Currently, film cooling effectiveness correlation of two-row compound angled cylindrical holes is not available, so this study developed the correlations for the inline arrangement of holes with opposing angles and the staggered arrangement of holes with same angles. The results and correlations are expected to provide useful information for the two-row flat plate film cooling analysis.


Author(s):  
Travis B. Watson ◽  
Kyle R. Vinton ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

Abstract The effect of film cooling hole inlet geometry is experimentally investigated in this study. Detailed film cooling effectiveness distributions are obtained on a flat plate using Pressure Sensitive Paint (PSP). The inlet of a traditional 12°-12°-12°, laidback, fanshaped hole varies from a traditional “round” opening to an oblong, racetrack shaped opening. In this study, a single racetrack inlet with an aspect ratio of 2:1 is compared to the round inlet. For both designs, the holes are inclined at θ = 30° relative to the mainstream. Blowing ratios of 0.5, 1.0, and 1.5 are considered as the coolant–to–mainstream density ratio varies between 1.0 and 4.0. For all cases, the freestream turbulence intensity is maintained at 7.5%. With the introduction of the racetrack shaped inlet, the coolant spreads laterally across the diffuse, laidback fanshaped outlet. The centerline film cooling effectiveness is reduced with the enhanced lateral spread of the coolant. However, the benefit of the shaped inlet is also observed with an increase in the area averaged film cooling effectiveness, compared to the traditional round inlet. Not only does the shaped inlet promote spreading of the coolant, it is also believed the racetrack shape suppresses turbulence within the hole allowing for enhanced film cooling protection near the film cooling holes.


Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film cooling holes, and the tip gap clearance on the film cooling effectiveness were studied and compared to plane tip. The film cooling effectiveness distributions were measured on the blade tip using Pressure Sensitive Paint technique. Air and nitrogen gas were used as the film cooling gases and the oxygen concentration distribution for each case was measured. The film cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film cooling holes were located (a) along the camber line on the tip or (b) along the span of the pressure side. The average blowing ratio of the cooling gas was controlled to be 0.5, 1.0, and 2.0. Tests were conducted in a five-bladed linear cascade with a blow down facility. The free stream Reynolds number, based on the axial chord length and the exit velocity, was 1,100,000 and the inlet and the exit Mach number were 0.25 and 0.59, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness.


Author(s):  
Sehjin Park ◽  
Eui Yeop Jung ◽  
Seon Ho Kim ◽  
Ho-Seong Sohn ◽  
Hyung Hee Cho

Film cooling is a cooling method used to protect the hot components of a gas turbine from high temperature conditions. For this purpose, high and uniform film cooling effectiveness is required to protect the vanes/blades from excessive thermal stress. Backward injection is proposed as one of the methods for the improvement of film cooling effectiveness. In this study, experiments were performed to investigate the effect of backward injection on film cooling effectiveness, using pressure sensitive paint (PSP) method. Four experimental configurations were composed of forward and backward injection cylindrical holes. The cylindrical holes were aligned in two staggered rows with pitch (p) of 6d and row spacing (s) of 3d. The injection angles (α) of the cylindrical holes were 35° and 145° for forward and backward injection, respectively. The blowing ratios (M) ranged from 0.5 to 2.0 and the density ratio (DR) was about 1. The results indicate that backward injection enhanced not only film cooling effectiveness but also the lateral cooling uniformity. At a high blowing ratio, all configurations demonstrated higher film cooling effectiveness with backward injection than with only forward injection; thus, the dispersion of the backward injection jets enhanced the lateral coverage over wide areas. Configuration, in particular, arranged with forward injection in the first row and backward injection in the second row, obtained the highest film cooling effectiveness among the four cases studied, due to the dispersion of the backward injection jets and the coolant supply from the forward injection jets at a high blowing ratio.


Author(s):  
JeongJu Kim ◽  
Wonjik Seo ◽  
Minho Bang ◽  
Seon Ho Kim ◽  
Seok Min Choi ◽  
...  

Film cooling effectiveness and heat transfer were measured in squealer tip configurations on the blade tip surface. Three different shelf squealer tip geometries were studied: conventional, vertical, and inclined. The experiment was carried out in a wind tunnel with an inlet mainstream Reynolds number, based on the axial chord length of the blade, of 140,000. The experiments were conducted in five blades in linear cascade with an averaged turbulence intensity of 8.5%. The film cooling effectiveness and heat transfer coefficient on the tip surface were obtained using the transient IR thermography technique. For the pressure side film cooling holes, averaging blowing ratios (M) of 1.0 and 2.0 were set. The results showed the film cooling effectiveness distributions on the tip surface. Owing to the mainstream, the cooling effect appeared after x/Cx = 0.15 and the film cooling effectiveness tended to increase toward downstream of the trailing edge. Additionally, the heat transfer distributions were investigated regarding the film cooling holes. In the presence of film cooling holes, the heat transfer distribution had more uniformity than without them on the pressure side. As the blowing ratio increased from 1 to 2, the heat transfer was decreased on the tip surface. The heat transfer ratio represented the change of heat transfer distribution with and without film cooling holes. Those of results were compared in three squealer tip geometries. The overall area-averaged net heat flux reduction (NHFR) levels on the tip surface were enhanced as the blowing ratio increased. The NHFR of the shelf squealer tip configurations was better than that with the conventional squealer tip.