Optimization of Working Ground Heat Storage With Seasonal Regeneration

Author(s):  
Pawel Olszewski

The aim of the research was an optimization of long-term heat storage with seasonal regeneration. Energy consumption for central heating during wintertime, transfererred from ground energy storage using a heat exchange device, is the operating principle of such systems. Warmed working fluid is then used in a heat pump system. However, more accurate calculations showed that over time of usage, there is a trend toward cooling at deeper round layers. Such a situation leads to a lowering of ground potential when using heat pump systems. A possible solution to this problem is the application of summer regeneration: during summer months, the working fluid is firstly warmed in solar collectors, and then forced into the same boreholes. The numerical model of a vertical, ground heat exchange device (configured as a "pipe in pipe", known as a Fields' pipe) was specially developed. Temperature distribution of the working fluid along the pipe was one of the boundary conditions, for the co-axial, time-variable, heat conduction task, which described the heat flow in energy storage. The numerical simulation of solar collectors work was based on the Hottel - Whillier - Bliss equation, in which energy flow from the solar collector is calculated, dependant on external parameters such as: insulation or ambience temperature. The combination of three computational parts- the ground heat exchange device, energy storage area and solar collectors battery- allows the target function to be defined for task optimization. The subject of optimization was an energy quantity, which can be taken from energy underground storage, and then utilized by the heat pump system. In the summarized paper, a combination of the input data, which influenced the efficiency of energy storage, was chosen. Hypothetical data were: outside diameter and length of heat exchange device, distance between pipes, fluid flow through the pipe during charge and discharge processes or temperature of inlet working fluid. The influence of individual parameters on the target function, holding all input data constant, was analyzed. A developed evolutionary numerical code known as GENOCOP I (GEnetic algorithm for Numerical Optimization for COnstrained Problems) [3] was used for optimization. After preliminary correction of boundary values of the input data, nine attempts of optimization were taken up. The research results identified optimal values of input parameters for which maximum energy could be taken from ground storage.

Author(s):  
Jung Chan Park ◽  
Kil Young Kim ◽  
Jinhee Jeong ◽  
Seung Jin Song

A typical turbo heat pump system consists of a centrifugal compressor, expansion valve, and two heat exchangers or plenums — a condenser and evaporator. Compared to a gas turbine, a turbo heat pump introduces additional complexities because it is a two-phase, closed-loop system with heat exchange using a real gas/liquid (refrigerant) as working fluid. For such systems, a new linear stability model has been developed by applying a linearized small perturbation method to the nonlinear turbo heat pump surge model. When the new linear model is applied to a compressor in an open loop system (e.g. turbocharger), results identical to those of Greitzer’s model are obtained. When applied to an operating turbo heat pump, the new model accurately predicts the surge onset point. Finally, results from a parametric study on the influence of the B parameter on surge onset are presented. Thus, the new model can be applied to predict stability of various compression systems — either open or closed-loop systems running single or two-phase working fluids with or without heat exchange.


2013 ◽  
Vol 860-863 ◽  
pp. 191-195
Author(s):  
Hong Chen Zhang ◽  
Hong Tao Wang ◽  
Feng Li Li ◽  
Li Qing Zhang

on the basis of the working principle of solar heat pump system is introduced in this paper, Focuses on the structure of the heat storage device and the selection of phase change materials, structure, The influence of phase change materials the size of the diameter to heat-exchange, The influence of phase change materials piled up form to heat-exchange, The influence of thermal fluid flow velocity to heat exchange , In-depth analysis of phase change materials and thermal fluid accumulation of heat and heat release process , Solve the problem of supercooling and dialysis of phase change heat storage materials, The use of phase change materials have a positive reference value.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1893
Author(s):  
Kwonye Kim ◽  
Jaemin Kim ◽  
Yujin Nam ◽  
Euyjoon Lee ◽  
Eunchul Kang ◽  
...  

A ground source heat pump system is a high-performance technology used for maintaining a stable underground temperature all year-round. However, the high costs for installation, such as for boring and drilling, is a drawback that prevents the system to be rapidly introduced into the market. This study proposes a modular ground heat exchanger (GHX) that can compensate for the disadvantages (such as high-boring/drilling costs) of the conventional vertical GHX. Through a real-scale experiment, a modular GHX was manufactured and buried at a depth of 4 m below ground level; the heat exchange rate and the change in underground temperatures during the GHX operation were tracked and calculated. The average heat exchanges rate was 78.98 W/m and 88.83 W/m during heating and cooling periods, respectively; the underground temperature decreased by 1.2 °C during heat extraction and increased by 4.4 °C during heat emission, with the heat pump (HP) working. The study showed that the modular GHX is a cost-effective alternative to the vertical GHX; further research is needed for application to actual small buildings.


Author(s):  
Haifei Chen ◽  
Guiqiang Li ◽  
Yueyue Ling ◽  
Jie Fu ◽  
Yunjie Wang ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-18 ◽  
Author(s):  
Yan Gao ◽  
Zhi Sun ◽  
Xinxing Lin ◽  
Chuang Wang ◽  
Zongyu Sun ◽  
...  

The cold accumulation problem can lead to performance degradation of heat pumps. This paper presents the design and optimization of a solar-assisted storage system to solve this issue. A ground source heat pump (GSHP) project was established using the transient system simulation program (TRNSYS) based on a ground heat exchange theoretical model, which was validated by a previously established experiment in Beijing. The Beijing, Harbin, and Zhengzhou regions were used in numerical simulations to represent three typical cities where buildings require space heating (a cold region, a severe cold region, and a hot summer and cold winter region, respectively). System performance was simulated over periods of ten years. The simulation results showed that the imbalance efficiencies in the Beijing, Harbin, and Zhengzhou regions are 55%, 79%, and 38%, respectively. The annual average soil temperature decreases 7.3°C, 11.0°C, and 5.3°C during ten years of conventional GSHP operation in the Beijing, Harbin, and Zhengzhou regions, respectively. Because of the soil temperature decrease, the minimum heating coefficient of performance (COP) values decrease by 23%, 46%, and 11% over the ten years for GSHP operation in these three regions, respectively. Moreover, the simulation data show that the soil temperature would still be decreasing if based on the previous solar energy area calculation method. Design parameters such as the solar collector size are optimized for the building load and average soil temperature in various cold regions. Long-term operation will test the matching rate of the compensation system with the conventional GSHP system. After the system is optimized, the solar collector area increases of 20% in the Beijing region, 25% in the Harbin region, and 15% in the Zhengzhou region could help to maintain the annual average soil temperature balance. The optimized system could maintain a higher annual average COP because of the steady soil temperature. It provides a method for the design of a solar collector area which needs to be determined in the seasonal heat storage solar ground source heat pump system.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4294
Author(s):  
Gaurav Shrestha ◽  
Mayumi Yoshioka ◽  
Hikari Fujii ◽  
Youhei Uchida

Evaluation of appropriate areas to introduce a closed-loop ground-source heat pump (GSHP) system in the case of a standard detached residence was conducted in Akita Plain, Japan. Depth of borehole heat exchanger (BHE) required to use a GSHP system was taken as the suitability index, which is simpler for the general public to understand and to promote the system. Heating and cooling loads of the standard size detached residence were calculated based on the 2013 Energy Conservation Standard. To estimate BHE depths and estimate a suitable area, identical 3D BHE models were constructed at 30 points in the plain. Required BHE depths were determined by performing heat exchange simulations at each location using the calculated loads and heat exchange rates. A suitability map showing distribution of the required BHE depths was prepared. BHE depths were shorter in the north-western area compared to the other parts, implying that the coastal lowlands in this area are more suitable for closed-loop system in the standard detached residences in terms of heat exchange performance as well as the cost reduction. Thickly distributed Quaternary System with higher thermal conductivity is contributing to shorter BHE depths. The suitability map is effective to adopt potential areas for the system installation in the standard detached Japanese residences.


2011 ◽  
Vol 374-377 ◽  
pp. 398-404 ◽  
Author(s):  
Ying Ning Hu ◽  
Ban Jun Peng ◽  
Shan Shan Hu ◽  
Jun Lin

A hot-water and air-conditioning (HWAC) combined ground sourse heat pump(GSHP) system with horizontal ground heat exchanger self-designed and actualized was presented in this paper. The heat transfer performance for the heat exchanger of two different pipe arrangements, three layers and four layers, respectively, was compared. It showed that the heat exchange quantity per pipe length for the pipe arrangement of three layers and four layers are 18.0 W/m and 15.0 W/m. The coefficient of performance (COP) of unit and system could remain 4.8 and 4.2 as GSHP system for heating water, and the COP of heating and cooling combination are up to 8.5 and 7.5, respectively. The power consumption of hot-water in a whole year is 9.0 kwh/t. The economy and feasibility analysis on vertical and horizontal ground heat exchanger were made, which showed that the investment cost per heat exchange quantity of horizontal ground heat exchanger is 51.4% lower than that of the vertical ground heat exchanger, but the occupied area of the former is 7 times larger than the latter's.


2017 ◽  
Vol 205 ◽  
pp. 4090-4097 ◽  
Author(s):  
Zhang Yin ◽  
Long Enshen ◽  
Zhao Xinhui ◽  
Jin Zhenghao ◽  
Liu Qinjian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document