Fatigue Test of Al-3%Ti Using Axial Loading Testing Machine for MEMS Materials

Author(s):  
Jun-Hyub Park ◽  
Hyeon Chang Choi ◽  
Chang Seung Lee ◽  
Sung-Hoon Choa ◽  
Man Sik Myung ◽  
...  

This paper presents high cycle fatigue properties of an Al-3%Ti thin film, used in a RF (radio-frequency) MEMS switch for a mobile phone. The thickness and width of the thin film of specimen are 1.1 μm and 480 μm, respectively. Tensile tests of five specimens are performed, from which the ultimate strength is found to be 144MPa. High cycle fatigue tests of six specimens are also performed, from which the fatigue strength coefficient and the fatigue strength exponent are found to be 336MPa and −0.1514, respectively.

2006 ◽  
Vol 110 ◽  
pp. 3-8 ◽  
Author(s):  
Jun Hyub Park ◽  
Chang Seung Lee ◽  
Yun Jae Kim

This paper presents high cycle fatigue properties of a Al-3%Ti thin film, used in a RF (radio-frequency) MEMS switch for a mobile phone. The thickness and width of the thin film of specimen are 1.1μm and 480.0μm, respectively. Tensile tests of five specimens are performed, from which the ultimate strength is found to be 144MPa. High cycle fatigue tests of six specimens are also performed, from which the fatigue strength coefficient and the fatigue strength exponent are found to be 336MPa and –0.1514, respectively.


Author(s):  
Jun-Hyub Park ◽  
Man Sik Myung ◽  
Yun-Jae Kim

This paper presents high cycle fatigue properties of an Al-3%Ti thin film, used in a RF (radio-frequency) MEMS switch for a mobile phone and also describes new test method for obtaining static and dynamic characteristics of thin film and reliability evaluation method on MEMS device with thin film developed by authors. Durability should be ensured for such devices under cycling load. Therefore, with the proposed specimen and test procedure, tensile and fatigue tests were performed to obtain mechanical and fatigue properties. The specimen was made with dimensions of 1000μm long, 1.0μm thickness, and 3 kinds of width, 50, 100 and 150μm. High cycle fatigue tests for each width were also performed, from which the fatigue strength coefficient and the fatigue strength exponent were found to be 193MPa and −0.02319 for 50μm, 181MPa and −0.02001 for 100μm, and 164MPa and −0.01322 for 150μm, respectively. We found that the narrower specimen is, the longer fatigue life of Al-3%Ti is and the wider specimen is, the more susceptible to stress level fatigue life of Al-3%Ti was.


2008 ◽  
Vol 385-387 ◽  
pp. 185-188 ◽  
Author(s):  
Yu Mochizuki ◽  
Masaki Nakajima ◽  
Toshihiro Shimizu

High cycle fatigue properties and failure mode in high strength steel tempered at low temperature were studied. The material used was Ni-Cr-Mo steel, JIS SNCM439, which was tempered at 453 K. After heat treatment, round bar specimens with hourglass shape were machined. Fatigue tests were performed using two kinds of specimens with two surface conditions, i.e., as-ground specimen and buff-finished specimen. Tests were conducted under rotating bending and axial loading. Under rotating bending, in as-ground specimens, fatigue failure took place in high cycle region above 107 cycles and failure mode was surface-related. On the other hand, buff-finished specimens exhibited the step-wise S-N curve, i.e., the subsurface fracture with a fish-eye was observed. However, under axial loading, even in buff-finished specimens the subsurface fracture didn’t occur due to small nonmetallic inclusions. Based on the results, the fatigue limit was estimated by the statistics of extremes. The prediction gave the conservative values.


2011 ◽  
Vol 295-297 ◽  
pp. 2386-2389 ◽  
Author(s):  
Ren Hui Tian ◽  
Qiao Lin Ouyang ◽  
Qing Yuan Wang

In order to investigate the effect of plasma nitriding treatment on fatigue behavior of titanium alloys, very high cycle fatigue tests were carried out for Ti-6Al-4V alloy using an ultrasonic fatigue machine under load control conditions for stress ratios of R=-1 at frequency of ƒ=20KHz. Experiment results showed that plasma nitriding treatment played the principal role in the internal fatigue crack initiation. More importantly, plasma nitriding treatment had a detrimental effect on fatigue properties of the investigated Ti-6Al-4V alloy, and the fatigue strength of material after plasma nitriding treatment appeared to be significantly reduced about 17% over the untreated material.


2018 ◽  
Vol 916 ◽  
pp. 166-169
Author(s):  
Ilhamdi ◽  
Toshifumi Kakiuchi ◽  
Hiromi Miura ◽  
Yoshihiko Uematsu

Tension-tension fatigue tests were conducted using ultrafine-grained commercially pure Titanium (Ti) plates fabricated by multi-directional forging (MDFing). The MDFed pure Ti plates with the thickness of 1 mm were developed aiming at dental implant application. The fatigue properties of MDFed pure Ti plates were superior to those of the conventional rolled pure Ti plates. The higher fatigue strengths in MDFed plates could be attributed to the much finer grains evolved by MDFing. Fatigue crack initiated from specimen surface, when number of cycles to failure was shorter than 106 cycles. In the high cycle fatigue (HCF) region, however, subsurface crack initiation with typical fish-eye feature was recognized in the MDFed pure Ti plate in spite of the thin thickness. Fractographic analyses revealed that no inclusion existed at the center of fish-eye. The subsurface crack initiation mechanism could be related to the inhomogeneity of microstructure with some coarse grains in the inner part of the plate.


2007 ◽  
Vol 546-549 ◽  
pp. 1535-1540 ◽  
Author(s):  
Li Ying Zeng ◽  
Yong Qing Zhao ◽  
Xiao Nan Mao ◽  
Yun Lian Qi

Tensile and high cycle fatigue (HCF) property for TiC particle reinforced titanium matrix composite has been studied in this paper. The results indicated that the composite possessed favorite comprehensive properties. The tensile properties for the composite are superior to that of the common high temperature titanium alloys, e.g. IMI834, Ti-1100. Smooth axial fatigue tests were taken at a frequency of 76Hz with a load ratio R of 0.06 and –1, respectively. And HCF strength for the composite at ambient temperature is 595MPa and 494MPa, respectively.


2008 ◽  
Vol 385-387 ◽  
pp. 849-852 ◽  
Author(s):  
Pasquale Cavaliere ◽  
Francesco W. Panella ◽  
Antonio Squillace

Al-Li alloys are characterized by a strong anisotropy in mechanical properties and microstructure with respect to the rolling direction. Plates of 2198 Al-Li alloy were friction stir welded by employing maximum rotation speed: 1000 rev/min and welding speed of 80 mm/min, both in parallel and orthogonal directions with respect to the rolling one. The joints mechanical properties were evaluated by means of tensile tests at room temperature. In addition, fatigue tests performed with a resonant electro-mechanical testing machine under constant amplitude control up to 250 Hz loading, were conducted in axial control mode with R(σmin/σmax)=0.33, for all the welding and rotating speed conditions. The fatigue crack propagation experiments were performed by employing single edge notched specimens.With the aim to characterize the weld performances, both the microstructure evolution at jointed cross sections, related to the welding variables, and the fractured surfaces were respectively analyzed by means of optical and scanning electron microscopy.


Author(s):  
Ming Zhang ◽  
Weiqiang Wang ◽  
Aiju Li

The authors researched the effects of specimen size on the very high cycle fatigue properties of FV520B-I through ultrasonic fatigue testing. The test results showed that the very high cycle fatigue mechanism was not changed and the fatigue properties declined as the specimen size increased. The S-N curve moved downward and the fatigue life decreased under the same stress level maybe due to the heat effects of large specimens in tests. The fatigue strength and the fatigue life were predicted by relevant models. The prediction of fatigue strength was close to test result, and the prediction of fatigue life was less effective compared with the previous prediction of small size specimen test results.


2013 ◽  
Vol 423-426 ◽  
pp. 197-201
Author(s):  
Xiao Min Zhang ◽  
Jian Mao ◽  
Yun Che ◽  
Zhong Ke Zhang

211Z is a new type of high strength and toughness Al-Cu-Mn casting aluminum alloy. With the aid of GPS-100 high-cycle fatigue testing machine and DDL100 multifunction tensile testing machine, conventional mechanics performance tests and high-cycle fatigue tests were carried out in this paper. The conventional mechanical property results show that the tensile strength is 477.5 MPa, the theory yield strength is 397.5 MPa and the elongation is 6.625%. Fatigue experiments were performed with load control at room temperature and R =-1 in ambient air. The tensile and compression fatigue strength is 130 MPa under ten million times fatigue test, and S-N fatigue life curve of this alloy was also given in the investigations. 211Z casting aluminum alloy possessing high fatigue strength can be attributed to the fact that it owns high strength and good plasticity simultaneously. The microstructure analysis of fatigue fracture appearance shows that, the fatigue crack initiation behavior of this aluminium alloys depends mainly on the region possessing defects under the surface, there has only one crack source, which means it is belongs to low nominal stress unidirectional bending. In the crack growth stage, the width of fatigue striations decreases with the increase of stress, and a few secondary cracks were found in this stage. When cracks finally losed stability, an instantaneous fracture occured in the investigated samples. Shear lips and dimples were found in the fracture appearance and the final fracture is belongs to ductile fracture.


Sign in / Sign up

Export Citation Format

Share Document