A Real-Time AC/DC Measurement Technique for Assessment of AC Corrosion of Buried Pipelines

Author(s):  
Cindy X. Su ◽  
Luyao Xu ◽  
Frank Y. Cheng

In this work, a real-time AC/DC signal data acquisition (DAQ) technique was developed, which is capable of separating the DC and AC potential components from the recorded total potential, providing mechanistic information about the steel corrosion in the presence of AC interference. It was found that the corrosion of the steel is enhanced by the applied AC current density from 0 to 400 A/m2. With the further increase to 600 A/m2 and 800 A/m2, the corrosion rate of the steel decreases, which is attributed to passivation of the steel at sufficiently high AC current densities, and a compact film is formed on the steel surface. Moreover, the derived mathematic relationships between AC potential and AC current density provides a potential alternative to determine AC current density on pipelines based on measurements of AC potential in the field.

Author(s):  
A. Q. Fu ◽  
Y. F. Cheng

The alternating current (AC)-induced corrosion of a cathodically protected X65 pipeline steel was studied in a high pH, concentrated carbonate/bicarbonate solution. Results demonstrated that the corrosion rate of the steel increases with the AC current density, and AC interference could increase the pitting corrosion of the steel. In the absence of AC interference or at a low AC current density, i.e., 20 A/m2, a cathodic protection (CP) potential of −950 mV(Cu/CuSO4 electrode, CSE), which is 100 mV more cathodic than −850 mV(CSE) recommended by National Association of Corrosion Engineers (NACE), provides a full protection over the steel. When the AC current density is higher than 20 A/m2, the NACE-recommended CP is incapable of protecting the pipeline from corrosion. A new CP standard is thus developed for recommendation to industry to avoid AC corrosion of pipelines.


2012 ◽  
Vol 263-266 ◽  
pp. 448-451 ◽  
Author(s):  
Xin Hua Wang ◽  
Guo Yong Yang ◽  
Hai Huang ◽  
Zhenhua Chen ◽  
Li Mei Wang

AC stray current can cause AC corrosion and destroy the safe operation of buried pipelines, which comes mainly from nearby high voltage transmission lines and AC electric railway. The research and evaluation lags far behind DC stray current at home and abroad, besides, the AC current density measuring procedures are complex. Through experimental study of different parameters on the impact of the AC current density established a mathematical model of damaged area, soil resistivity, pipe-to-soil potential and coating resistivity. With it can indirectly get the AC current density, which improve efficiency by simplifying the measuring procedures. Also, provide a basis for harmfulness evaluation of AC stray current by studying the impact of AC current density on the corrosion rate.


Author(s):  
I-Fei Tsu ◽  
D.L. Kaiser ◽  
S.E. Babcock

A current theme in the study of the critical current density behavior of YBa2Cu3O7-δ (YBCO) grain boundaries is that their electromagnetic properties are heterogeneous on various length scales ranging from 10s of microns to ˜ 1 Å. Recently, combined electromagnetic and TEM studies on four flux-grown bicrystals have demonstrated a direct correlation between the length scale of the boundaries’ saw-tooth facet configurations and the apparent length scale of the electrical heterogeneity. In that work, enhanced critical current densities are observed at applied fields where the facet period is commensurate with the spacing of the Abrikosov flux vortices which must be pinned if higher critical current density values are recorded. To understand the microstructural origin of the flux pinning, the grain boundary topography and grain boundary dislocation (GBD) network structure of [001] tilt YBCO bicrystals were studied by TEM and HRTEM.


Author(s):  
M. R. McCartney ◽  
J. K. Weiss ◽  
David J. Smith

It is well-known that electron-beam irradiation within the electron microscope can induce a variety of surface reactions. In the particular case of maximally-valent transition-metal oxides (TMO), which are susceptible to electron-stimulated desorption (ESD) of oxygen, it is apparent that the final reduced product depends, amongst other things, upon the ionicity of the original oxide, the energy and current density of the incident electrons, and the residual microscope vacuum. For example, when TMO are irradiated in a high-resolution electron microscope (HREM) at current densities of 5-50 A/cm2, epitaxial layers of the monoxide phase are found. In contrast, when these oxides are exposed to the extreme current density probe of an EM equipped with a field emission gun (FEG), the irradiated area has been reported to develop either holes or regions almost completely depleted of oxygen. ’ In this paper, we describe the responses of three TMO (WO3, V2O5 and TiO2) when irradiated by the focussed probe of a Philips 400ST FEG TEM, also equipped with a Gatan 666 Parallel Electron Energy Loss Spectrometer (P-EELS). The multi-channel analyzer of the spectrometer was modified to take advantage of the extremely rapid acquisition capabilities of the P-EELS to obtain time-resolved spectra of the oxides during the irradiation period. After irradiation, the specimens were immediately removed to a JEM-4000EX HREM for imaging of the damaged regions.


1995 ◽  
Vol 391 ◽  
Author(s):  
S. P. Riege ◽  
A. W. Hunt ◽  
J. A. Prybyla

AbstractDirect real-time observations of electromigration (EM) in submicron Al interconnects were made using a special sample-stage which allowed TEM observations to be recorded while simultaneously heating and passing current through the sample. The samples consisted of 4000 Å thick Al(0.5wt%Cu) patterned over a TEM-transparent window into five runners in parallel, with linewidths 0.2, 0.3, 0.5, 0.8, and 1.0 μm. Both passivated and unpassivated samples were examined. A current density of 2 x 106A/cm2 was used with temperatures ranging from 200 - 350°C. The experiments were done using constant voltage testing, and we used a special sample design which dramatically minimized Joule-heating. Our approach has allowed us to directly observe voids form, grow, migrate, pin, fail a runner, and heal, all with respect to the detailed local microstructure of the runners.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Fanxiu Chen ◽  
Zuquan Jin ◽  
Endong Wang ◽  
Lanqin Wang ◽  
Yudan Jiang ◽  
...  

AbstractConcrete cracking caused by corrosion of reinforcement could significantly shorten the durability of reinforced concrete structure. It remains critical to investigate the process and mechanism of the corrosion occurring to concrete reinforcement and establish the theoretical prediction model of concrete expansion force for the whole process of corrosion cracking of reinforcement. Under the premise of uniform corrosion of reinforcing steel bars, the elastic mechanics analysis method is adopted to analyze the entire process starting from the corrosion of steel bars to the cracking of concrete due to corrosion. A relationship model between the expansion force of corrosion of steel bars and the surface strain of concrete is established. On the cuboid reinforced concrete specimens with square cross-sections, accelerated corrosion tests are carried out to calibrate and verify the established model. The model can be able to estimate the real-time expansion force of reinforced concrete at any time of the whole process from the initiation of steel corrosion to the end of concrete cracking by measuring the surface strain of concrete. It could be useful for quantitative real-time monitoring of steel corrosion in concrete structures.


Coatings ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 56
Author(s):  
Ashutosh Sharma ◽  
Byungmin Ahn

Metallic and alloyed coatings are used widely in several decorative and technology-based applications. In this work, we selected Sn coatings plated on Cu substrates for joining applications. We employed two different plating baths for the fabrication of Sn and Ni coatings: acidic stannous sulfate for Sn and Watts bath for Ni layer. The plating current densities were varied from 100–500 mA/cm2. Further, the wear and friction behavior of the coatings were studied using a ball-on-disc apparatus under dry sliding conditions. The impact of current density was studied on the morphology, wear, and coefficient of friction (COF) of the resultant coatings. The wear experiments were done at various loads from 2–10 N. The sliding distance was fixed to 7 m. The wear loss was quantified in terms of the volume of the track geometry (width and depth of the tracks). The results indicate that current density has an important role in tailoring the composition and morphology of coatings, which affects the wear properties. At higher loads (8–10 N), Sn coatings on Ni/Cu had higher volume loss with a stable COF due to a mixed adhesive and oxidative type of wear mechanism.


2012 ◽  
Vol 302 (8) ◽  
pp. H1645-H1654 ◽  
Author(s):  
Toshihide Kashihara ◽  
Tsutomu Nakada ◽  
Hisashi Shimojo ◽  
Miwa Horiuchi-Hirose ◽  
Simmon Gomi ◽  
...  

L-type Ca2+ channels (LTCCs) play an essential role in the excitation-contraction coupling of ventricular myocytes. We previously found that t-tubular (TT) LTCC current density was halved by the activation of protein phosphatase (PP)1 and/or PP2A, whereas surface sarcolemmal (SS) LTCC current density was increased by the inhibition of PP1 and/or PP2A activity in failing ventricular myocytes of mice chronically treated with isoproterenol (ISO mice). In the present study, we examined the possible involvement of inhibitory heterotrimeric G proteins (Gi/o) in these abnormalities by chronically administrating pertussis toxin (PTX) to ISO mice (ISO + PTX mice). Compared with ISO mice, ISO + PTX mice exhibited significantly higher fractional shortening of the left ventricle. The expression level of Gαi2 proteins was not altered by the treatment of mice with ISO and/or PTX. ISO + PTX myocytes had normal TT and SS LTCC current densities because they had higher and lower availability and/or open probability of TT and SS LTCCs than ISO myocytes, respectively. A selective PKA inhibitor, H-89, did not affect LTCC current densities in ISO + PTX myocytes. A selective PP2A inhibitor, fostriecin, did not affect SS or TT current density in control or ISO + PTX myocytes but significantly increased TT but not SS LTCC current density in ISO myocytes. These results indicate that chronic receptor-mediated activation of Gi/o in vivo decreases basal TT LTCC activity by activating PP2A and increases basal SS LTCC activity by inhibiting PP1 without modulating PKA in heart failure.


1994 ◽  
Vol 369 ◽  
Author(s):  
Steen Skaarup ◽  
L.M.W.K. Gunaratne ◽  
Keld West ◽  
Birgit Zachau-Christiansen

AbstractPolyaniline has been synthesized in propylene carbonate by galvanostatic electrochemical polymerization at current densities between 16 and 1000 μA/cm2. Earlier results for polypyrrole have shown that low and high current density films have different properties: The films synthesized at low current density have a higher conjugation length and a more regular structure. The corresponding effect in PANI has been investigated by cyclic voltammetry and UV/visible spectroscopy. Simultaneous measurement of cyclic voltammograms and the absorbtion of selected spectral lines is used because of the complex nature of the PANI system which involves several redox systems as well as forms differing in the degree of protonation and morphology.The main result is that the method of galvanostatic synthesis at low current densities (-16 μA/cm2) produces polyaniline polymers of different, more conjugated and more regular structure than those prepared at higher current densities. The standard method of in situ layer-by-layer polymerization of conducting polymers during cyclic voltammetry often results in uncontrolled and unmeasured current densities of 0.5-2 mA/cm2 which produces a film that probably has a less regular structure containing more deviations from ideality.


2014 ◽  
Vol 635 ◽  
pp. 204-207 ◽  
Author(s):  
Ondrej Milkovič ◽  
Mária Hagarová ◽  
Jana Michaliková ◽  
Matúš Horváth

In this article we focused to influence of current density on the structure parameters evaluated by microdiffraction experiment in transmission mode using synchrotron radiation. For this purpose the coatings of Ni-Co alloy were deposited on the Cu substrate using different current densities during the electrodeposition process. The results of the microdiffraction experiment showed the structure uniformity of the coatings along their thickness, as well as changes in the structure parameters depending on the used current density during the deposition process.


Sign in / Sign up

Export Citation Format