Fluorescence molecular imaging system with a novel mouse surface extraction method and a rotary scanning scheme

Author(s):  
Yue Zhao ◽  
Dianwen Zhu ◽  
Reheman Baikejiang ◽  
Changqing Li
2018 ◽  
Vol 17 (1) ◽  
Author(s):  
Kedi Zhou ◽  
Yichen Ding ◽  
Ivan Vuletic ◽  
Yonglu Tian ◽  
Jun Li ◽  
...  

2003 ◽  
Vol 30 (5) ◽  
pp. 901-911 ◽  
Author(s):  
Edward E. Graves ◽  
Jorge Ripoll ◽  
Ralph Weissleder ◽  
Vasilis Ntziachristos

IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 93663-93670
Author(s):  
Farouk Nouizi ◽  
Jamison Brooks ◽  
Darren M. Zuro ◽  
Srideshikan Sargur Madabushi ◽  
Dayson Moreira ◽  
...  

2004 ◽  
Vol 4 (4) ◽  
pp. 419-430 ◽  
Author(s):  
E. Graves ◽  
R. Weissleder ◽  
V. Ntziachristos

2011 ◽  
Vol 71 ◽  
pp. e196
Author(s):  
Takatoshi Ueki ◽  
Hiromu Furukawa ◽  
Gandhervin Kesavamoorthy ◽  
Kohji Sato ◽  
Yasuomi Ouchi

Oral Oncology ◽  
2021 ◽  
Vol 118 ◽  
pp. 17
Author(s):  
J. Vonk ◽  
J.G. deWit ◽  
F.J. Voskuil ◽  
Y.H. Tang ◽  
W.T.R. Hooghiemstra ◽  
...  

Theranostics ◽  
2014 ◽  
Vol 4 (11) ◽  
pp. 1072-1084 ◽  
Author(s):  
Chongwei Chi ◽  
Yang Du ◽  
Jinzuo Ye ◽  
Deqiang Kou ◽  
Jingdan Qiu ◽  
...  

Author(s):  
Zhen Liu ◽  
Tao Cheng ◽  
Stephan Düwel ◽  
Ziying Jian ◽  
Geoffrey J. Topping ◽  
...  

Abstract Background Transpathology highlights the interpretation of the underlying physiology behind molecular imaging. However, it remains challenging due to the discrepancies between in vivo and in vitro measurements and difficulties of precise co-registration between trans-scaled images. This study aims to develop a multimodal intravital molecular imaging (MIMI) system as a tool for in vivo tumour transpathology investigation. Methods The proposed MIMI system integrates high-resolution positron imaging, magnetic resonance imaging (MRI) and microscopic imaging on a dorsal skin window chamber on an athymic nude rat. The window chamber frame was designed to be compatible with multimodal imaging and its fiducial markers were customized for precise physical alignment among modalities. The co-registration accuracy was evaluated based on phantoms with thin catheters. For proof of concept, tumour models of the human colorectal adenocarcinoma cell line HT-29 were imaged. The tissue within the window chamber was sectioned, fixed and haematoxylin–eosin (HE) stained for comparison with multimodal in vivo imaging. Results The final MIMI system had a maximum field of view (FOV) of 18 mm × 18 mm. Using the fiducial markers and the tubing phantom, the co-registration errors are 0.18 ± 0.27 mm between MRI and positron imaging, 0.19 ± 0.22 mm between positron imaging and microscopic imaging and 0.15 ± 0.27 mm between MRI and microscopic imaging. A pilot test demonstrated that the MIMI system provides an integrative visualization of the tumour anatomy, vasculatures and metabolism of the in vivo tumour microenvironment, which was consistent with ex vivo pathology. Conclusions The established multimodal intravital imaging system provided a co-registered in vivo platform for trans-scale and transparent investigation of the underlying pathology behind imaging, which has the potential to enhance the translation of molecular imaging.


Sign in / Sign up

Export Citation Format

Share Document