Long-Term Changes in Invasive Physiological Pressure Indices of Stenosis Severity Following Transcatheter Aortic Valve Implantation

Author(s):  
Muhammad Sabbah ◽  
Francis R. Joshi ◽  
Mikko Minkkinen ◽  
Lene Holmvang ◽  
Hans-Henrik Tilsted ◽  
...  

Background: Patients with severe aortic stenosis frequently have coexisting coronary artery disease. Invasive hyperemic and nonhyperemic pressure indices are used to assess coronary artery disease severity but have not been evaluated in the context of severe aortic stenosis. Methods: We compared lesion reclassification rates of fractional flow reserve (FFR) and resting full-cycle ratio (RFR) measured before and 6 months after transcatheter aortic valve implantation using the conventional clinical cutoffs of ≤0.80 for FFR and ≤0.89 for RFR. This was a substudy of the ongoing NOTION-3 trial (Third Nordic Aortic Valve Intervention). Two-dimensional quantitative coronary analysis was used to assess changes in angiographic lesion severity. Results: Forty patients were included contributing 50 lesions in which FFR was measured. In 32 patients (36 lesions), RFR was also measured. There was no significant change in diameter stenosis from baseline to follow-up, 49.8% (42.9%–57.1%) versus 52.3% (43.2%–57.8%), P =0.50. RFR improved significantly from 0.88 (0.83%–0.93) at baseline to 0.92 (0.83–0.95) at follow-up, P =0.003, whereas FFR remained unchanged, 0.84 (0.81–0.89) versus 0.86 (0.78–0.90), P =0.72. At baseline, 11 out of 50 (22%) lesions were FFR-positive, whereas 15 out of 50 (30%) were positive at follow-up, P =0.219. Corresponding numbers for RFR were 23 out of 36 (64%) at baseline and 12 out of 36 (33%) at follow-up, P =0.003. Conclusions: In patients with severe aortic stenosis, physiological assessment of coronary lesions with FFR before transcatheter aortic valve implantation leads to lower reclassification rate at 6-month follow-up, compared with RFR.

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
B Lattuca ◽  
A Meilhac ◽  
C Robert ◽  
D Vandenbergh ◽  
F Manna ◽  
...  

Abstract Background With the growing indications of transcatheter aortic valve implantation (TAVI) worldwide and among lower risk patients, valve durability has become a crucial issue. Purpose To assess mid and long-term evolution of different generations of percutaneous balloon-expandable prostheses, predictive factors of valve deterioration and its correlation with long-term mortality. Methods All consecutive patients undergoing TAVI for severe aortic stenosis with balloon-expandable prosthesis between 2009 and 2014 and with a minimum follow-up of one-year were included in this monocentric prospective study. All echocardiograms were reviewed by two independent experts. Clinical events were defined according to the Valve Academic Research Consortium criteria. Valve deterioration was defined according to the 2017 EAPCI-ESC-EACTS international consensus statement at the longest follow-up. Results A total of 160 patients were included with a median follow-up of 3.4 years [1.5–4.9] and a maximum of 8 years. Patients were mostly implanted with the first generation Sapien XT valve (n=138, 86.2%). Median age was 85 [79–86] years, with 42.5% of women and a median logistic Euro-SCORE of 14.2% [10.6–23.2]. Immediately after TAVI, mean aortic gradient decreased dramatically from 51±12mmHg to 9±2.6mmHg (p<0.0001) and remained overall stable with a mean gradient of 12±1mmHg at 8 years. Valve deterioration occurred in 5.6% (n=9) of patients, of which 3.7% (n=6) with severe deterioration. Moderate or severe peri-prosthetic aortic regurgitation was observed in 2.5% (n=4) of patients. The eight-year survival rate was 12.9%. During follow-up, hospitalization for acute heart failure was required for 23.7% (n=38) of patients, a myocardial infarction or a stroke occurred respectively among 1.9% (n=3) and 5% (n=8) of patients. After multivariate analysis, size or generation of valves were not independent predictive factors of valve deterioration. Evolution of mean aortic gradient Conclusions After a maximal 8-year follow-up, valve deterioration after balloon-expandable TAVI is very low. In this high-risk population, TAVI seems to be a safe and durable alternative to surgery in severe aortic stenosis regardless of prosthesis generation. Acknowledgement/Funding Edwards Lifesciences


2020 ◽  
Vol 23 (2) ◽  
pp. E250-E254
Author(s):  
Hiroshi Kadowaki ◽  
Kazuyuki Yahagi ◽  
Yu Horiuchi ◽  
Kengo Tanabe

Background: In candidates for transcatheter aortic valve implantation (TAVI), preoperative computed tomography (CT) may detect clinically relevant non-cardiac findings. In particular, when malignant findings are detected, patients may be less likely to undergo the procedure. Additionally, they might require further examinations, which may prolong their time to treatment. We investigated how malignant findings affect candidacy for TAVI. Methods: In this single-center retrospective study, 98 patients with severe aortic stenosis who had undergone preoperative CT between September 2013 and October 2016 were evaluated for malignant findings. Results: Seven patients (7.1%) had malignant findings. 74 of 91 patients who did not have malignant findings underwent TAVI, SAVR, or balloon aortic valvuloplasty (81.3%). All patients who had malignant findings underwent TAVI or SAVR, and they underwent the procedure sooner after CT than the rest of the patients (mean time to TAVI or SAVR: 24.6 ± 16.8 versus 48.5 ± 45.4 days; P = .003). All 5 patients who had malignant findings without metastatic cancer and who underwent TAVI were still alive during the follow-up period (the mean duration of the follow-up period was 22.3 ± 8.8 months). However, 1 patient who had a malignant finding with metastatic cancer died 7 months after CT. Conclusion: Our outcomes indicated that the mean duration before TAVI or SAVR was reduced when malignant findings were detected by CT; and TAVI may be a safe and effective treatment for patients with aortic stenosis and a malignant tumor.


Sign in / Sign up

Export Citation Format

Share Document