Influence of needle gauge and venepuncture difficulty on thromboelastography in healthy cats

2018 ◽  
Vol 21 (8) ◽  
pp. 708-713 ◽  
Author(s):  
Duree Shin ◽  
Aryung Nam ◽  
Kun Ho Song ◽  
Kyoung Won Seo

Objectives The aim of this study was to evaluate the effect of two differently sized butterfly catheter needles and the effect of venepuncture difficulty on thromboelastography (TEG) results in healthy cats. Methods Twenty-four healthy cats were included. Blood samples were collected from the jugular vein by syringe aspiration via direct venepuncture with 21 G and 22 G butterfly needles. The venepuncture difficulty score was classified into four categories. The first 1.5 ml blood drawn from each subject was discarded before collecting a sample for TEG analysis. TEG analyses were performed on citrated whole blood samples from 17 clinically healthy cats, using assays with kaolin as activators. Among the TEG parameters, reaction time (R), clot formation time (κ), alpha angle (α), maximum amplitude (MA) and global clot strength (G) were recorded from each tracing. Results Seven cats were excluded from the study; results were obtained for the remaining 17 cats. There were no statistically significant differences between the use of two different needles for R ( P = 0.72), κ ( P = 0.74), α ( P = 0.99), MA ( P = 0.08) and G ( P = 0.09). Samples with difficulty scores ⩾1 were not significantly different from samples with difficulty scores of 0 for R ( P = 0.24), κ ( P = 0.65), α ( P = 0.65), MA ( P = 0.72) and G ( P = 0.77). Conclusions and relevance The results of TEG in clinically healthy cats do not differ significantly when using two different gauge needles. There was no significant difference in the TEG results according to venepuncture difficulty scoring.

2011 ◽  
Vol 23 (6) ◽  
pp. 1109-1113 ◽  
Author(s):  
Amrita Banerjee ◽  
Shauna L. Blois ◽  
R. Darren Wood

Thromboelastography (TEG) is a point-of-care whole blood test of hemostasis. While TEG is becoming more widely used in veterinary medicine, few studies describe the use of TEG in cats. The objectives of the current study were to: 1) document the range of TEG variables produced in healthy cats using 3 sample types (citrated native, kaolin-activated, and tissue factor–activated), and 2) determine if there was a significant difference between 2 separate samples obtained from individual healthy cats on the same day. Jugular venipuncture was performed in 20 cats, and citrated blood collected for TEG. TEG analysis was performed on citrated native, kaolin-activated, and tissue factor–activated blood for each sample. Two hours later, the procedure was repeated from the opposite jugular vein, yielding a total of 120 analyses. Reaction time ( R), alpha angle (α), kappa value (κ), and maximum amplitude (MA) were recorded from each tracing. No significant differences were found between TEG tracings from the first and second venipuncture samples. Significant differences were found between sample types for R, α, κ, and MA. Means for citrated native/kaolin-activated/tissue factor–activated methods were R = 4.1/3.7/0.6 min; κ = 2.5/1.8/2.2 min; α = 59.9/65.1/70.4 degrees; MA = 47.4/49.9/44.7 mm. A limitation of this study was the small number of cats used. Thromboelastography analysis may be a suitable method of evaluating hemostasis in cats.


2021 ◽  
pp. 000313482110335
Author(s):  
Alison Smith ◽  
Juan Duchesne ◽  
Matthew Marturano ◽  
Shaun Lawicki ◽  
Kevin Sexton ◽  
...  

Background Viscoelastic tests including thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are being used in patients with severe hemorrhage at trauma centers to guide resuscitation. Several recent studies demonstrated hypercoagulability in female trauma patients that was associated with a survival advantage. The objective of our study was to elucidate the effects of gender differences in TEG/ROTEM values on survival in trauma patients with severe hemorrhage. Methods A retrospective review of consecutive adult patients receiving massive transfusion protocol (MTP) at 7 Level I trauma centers was performed from 2013 to 2018. Data were stratified by gender and then further examined by TEG or ROTEM parameters. Results were analyzed using univariate and multi-variate analyses. Results A total of 1565 patients were included with 70.9% male gender (n = 1110/1565). Female trauma patients were older than male patients (43.5 ± .9 vs 41.1 ± .6 years, P = .01). On TEG, females had longer reaction times (6.1 ± .9 min vs 4.8 ± .2 min, P = .03), increased alpha angle (68.6 ± .8 vs 65.7 ± .4, P < .001), and higher maximum amplitude (59.8 ± .8 vs 56.3 ± .4, P < .001). On ROTEM, females had significantly longer clot time (99.2 ± 13.7 vs 75.1 ± 2.6 sec, P = .09) and clot formation time (153.6 ± 10.6 sec vs 106.9 ± 3.8 sec, P < .001). When comparing by gender, no difference for in-hospital mortality was found for patients in the TEG or ROTEM group ( P > .05). Multivariate analysis showed no survival difference for female patients (OR 1.11, 95% CI .83-1.50, P = .48). Conclusions Although a difference between male and females was found on TEG/ROTEM for certain clotting parameters, no difference in mortality was observed. Prospective multi-institutional studies are needed.


2020 ◽  
Vol 48 (1) ◽  
pp. 43-52
Author(s):  
Qi Wong ◽  
Kelly P Byrne ◽  
Scott C Robinson

TEG6s® is a new device introduced by the Haemonetics Corporation and designed to provide the same information as TEG® 5000 (Haemonetics Corporation, Braintree, MA, USA) but with much greater ease of use. We tested whether using citrated TEG6s gave reaction time, maximum amplitude and percentage of clot that had lysed at 30 minutes values similar to a non-citrated TEG5000, to allow clinical interchangeability using our current thrombelastography management algorithm for cardiac surgery. We also examined the agreement between the alpha-angle and functional fibrinogen maximum amplitude in our cardiac surgical patients.  In total, 243 paired arterial blood samples in 99 patients were tested, using TEG5000 (non-citrated) and TEG6s (citrated) after induction of anaesthesia (prior to heparin administration), following protamine administration at the end of the cardiac bypass and whenever a TEG5000 was requested after this by the attending anaesthetist. Bland–Altman plots and Lin’s concordance coefficient were used to compare agreement whereas modified Bland–Altman plots and McNemar’s test were used to illustrate the differences in management recommendations between the two thrombelastography devices.  All 243 samples were compared for reaction time and alpha-angle; 239 samples were compared for maximum amplitude; 136 samples were compared for the percentage of clot that had lysed at 30 minutes; 16 samples were compared for functional fibrinogen maximum amplitude. Lin’s concordance coefficient for these parameters was: reaction time 0.63, alpha-angle 0.39, maximum amplitude 0.5, percentage of clot that had lysed at 30 minutes 0.09 and functional fibrinogen maximum amplitude 0.31. Differences between the two devices became more marked at more abnormal values. Significant differences in median values, suggesting a fixed bias, were found for maximum amplitude and functional fibrinogen maximum amplitude. Differences in treatment recommendation could only be calculated for reaction time and maximum amplitude. Maximum amplitude was found to have a significant difference in treatment recommendation between the two devices using our current thrombelastography management algorithm for cardiac surgery with TEG6s recommending treatment in 11.5% more patients than TEG5000.  Using the TEG6s with our current TEG5000–based thrombelastography management algorithm for cardiac surgery would result in a change in treatment recommendation in at least 10% of our cardiac surgical patients. Agreement between the two thrombelastography devices appears to decrease with increasing patient coagulopathy. New algorithms will need to be developed and tested to validate TEG6s for cardiac surgical patients in our institution.


Blood ◽  
1998 ◽  
Vol 91 (11) ◽  
pp. 4216-4223 ◽  
Author(s):  
Nigel S. Key ◽  
Arne Slungaard ◽  
Luke Dandelet ◽  
Stephen C. Nelson ◽  
Christopher Moertel ◽  
...  

Abstract We developed a simple assay for the measurement of tissue factor procoagulant activity (TF PCA) in whole blood samples that avoids the need for mononuclear cell isolation. This method combines convenience of sample collection and processing with a high degree of sensitivity and specificity for TF. Using this method, we have determined that TF PCA is detectable in whole blood samples from normal individuals, which is itself a novel observation. Essentially all PCA could be shown to be localized in the mononuclear cell fraction of blood. Compared with controls, whole blood TF levels were significantly (P &lt; .000001) elevated in patients with sickle cell disease (SCD), regardless of the subtype of hemoglobinopathy (SS or SC disease). No significant difference in TF PCA was observed between patients in pain crisis compared with those in steady-state disease. Because TF functions as cofactor in the proteolytic conversion of FVII to FVIIa in vitro, it was expected that an increase in circulating TF PCA would lead to an increased in vivo generation of FVIIa. On the contrary, FVIIa levels were actually decreased in the plasma of patients with SCD. Plasma TF pathway inhibitor (TFPI) antigen levels were normal in SCD patients, suggesting that accelerated clearance of FVIIa by the TFPI pathway was not responsible for the reduced FVIIa levels. We propose that elevated levels of circulating TF PCA may play an important role in triggering the activation of coagulation known to occur in patients with SCD. Because TF is the principal cellular ligand for FVIIa, it is possible that increased binding to TF accounts for the diminished plasma FVIIa levels.


2019 ◽  
Vol 12 (2) ◽  

This study was conducted to determine the effect of bone marrow stromal cells (BMSCs) on progesterone level during pregnancy in ewes. Flurogestone Acetate Sponges 40 mg, followed by 400 i.u. Equine chorionic gonadotropin (eCG) were used to synchronize estrus and ovulation. The animals were divided into three equal groups (5 animals for each group). The 1st and 2nd group injected intravenously after eCG injection with 1x108 and 2x108 respectively with BMSCs while the 3rd group was injected with normal saline which serve as a control group. Blood samples were collected during pregnancy, at day 10, 21, 85 from the jugular vein. At day 10, 21 the results showed that there was a significant difference (p≤0.05) in the level of progesterone between treated groups as compared with the control group. While there was no significant difference between different groups at day 85. It was concluded from this study that BMSCs have a beneficial effect in ewe’s reproductive system, by increasing the level of progesterone at early pregnancy.


2021 ◽  
Author(s):  
Huan Zhao ◽  
Enben Su ◽  
Li Huang ◽  
Yunfeng Zai ◽  
Yuan Liu ◽  
...  

Abstract Background: Chemiluminescence immunoassay (CLIA) has always been a great challenge in detecting whole blood samples without centrifugation because of the interference of red blood cells and low sensitivity. Results: In this scheme, the antigens and erythrocytes in the blood were captured by the antibodies immobilized on the magnetic particles, recognized by another biotin-conjugated cTnI antibody and detected by streptavidin/acridine aster-conjugated PCMS. After magnetic separation, the supernatant was transferred and measured. No significant difference was noted between the cTnI concentrations of the serum samples, plasma samples and whole blood. The prepared PCMS provided more functional areas to conjugate streptavidin and acridinium ester, so the immunoassay has highly sensitive, the limits of blank at 0.012 ng/mL, and functional sensitivity at 0.019 ng/mL with a CV of 20%, and 0.058 ng/mL with a CV of 10%. Total precision of any sample type ranged from 2.62~5.67%. The assay was linear over the studied range of 0.01–50.00 ng/mL, and no hook effect was found when cTnI concentrations reached 1900 ng/mL. No significant interference was noted with the potential endogenous interfering substances. Compared with the commercial kit (Abbott assay kit), the correlation coefficient was 0.9859.Conclusions: A washing-free chemiluminescence immunoassay (CLIA) was established for the rapid detection of cardiac troponin I (cTnI) in human whole blood, using erythrocyte capture antibodies-conjugated magnetic nanoparticles for eliminating the influence of erythrocytes and polychloromethylstyrene microspheres (PCMS) for signal amplification, which showed great potential in clinical application.


2012 ◽  
Vol 107 (06) ◽  
pp. 1066-1071 ◽  
Author(s):  
Daniel Martin ◽  
Jim Pate ◽  
Andre Vercueil ◽  
Patrick Doyle ◽  
Michael Mythen ◽  
...  

SummaryThe impact of hypoxaemia on blood coagulation remains unclear despite use of a variety of measures to address the issue. We report the first use of thromboelastography (TEG) at high altitude to describe the dynamics of clot formation in whole blood samples. Seventeen healthy volunteers ascended to 5,300 m following an identical ascent profile; TEG measurements at 4,250 m and 5,300 m were compared with those from sea level. Peripheral oxygen saturation (SpO2) and haematocrit were also measured. Ascent resulted in a decline in SpO2 from 97.8 (± 1.2) % at sea level to 86.9 (± 3.3) % at 4,250 m and 79.5 (± 5.8) % at 5,300 m (p<0.001); haematocrit rose from 43.7 (± 2.8) % at sea level, to 46.7 (± 3.9) % and 52.6 (± 3.2) % at 4,250 m and 5,300 m, respectively (p<0.01). TEG reaction (R)-time and kinetic (K)-time were both increased at 5,300 m compared to sea level, 8.95 (± 1.37) minutes (min) to 11.69 (± 2.91) min (p=0.016) and 2.40 (± 0.66) min to 4.99 (± 1.67) min (p<0.001), respectively. Additionally the alpha (α)- angle was decreased from 57.7 (± 8.2) to 51.6 (± 6.4) (p<0.001). There was no change in maximum amplitude (MA) on ascent to altitude. These changes are consistent with an overall pattern of slowed coagulation at high altitude.


2001 ◽  
Vol 95 (5) ◽  
pp. 1169-1174 ◽  
Author(s):  
Michael S. Avidan ◽  
Jorge Da Fonseca ◽  
Kiran Parmar ◽  
Emma Alcock ◽  
José Ponte ◽  
...  

Background Thromboelastography is used for assessment of hemostasis. Adherence to thromboelastography-guided algorithms and aprotinin administration each decrease bleeding and blood product usage after cardiac surgery. Aprotinin, through inhibition of kallikrein, causes prolongation of the celite-activated clotting time and the activated partial thromboplastin ratio. The aim of this study was to assess the effects of aprotinin on the thromboelastography trace. Methods Three activators were used in the thromboelastography: celite (which is widely established), kaolin, and tissue factor. Assessment was performed on blood from volunteers and from patients before and after cardiac surgery. Results The tissue factor-activated thromboelastography trace was unaffected by the addition of aprotinin. When celite and kaolin were used as activators in the presence of aprotinin, the reaction time (time to clot formation) of the thromboelastography trace was prolonged (P &lt; 0.0001) and the maximum amplitude (clot strength) was decreased (P &lt; 0.05). With celite as an activator, the addition of aprotinin decreased (P &lt; 0.05) the thromboelastography alpha angle (rate of clot extension). The reaction time of the celite-activated trace correlated with the activated partial thromboplastin ratio (P &lt; 0.01). The reaction time of the tissue factor-activated trace correlated with the international normalized ratio (P &lt; 0.01). Conclusion The thromboelastography trace is altered in the presence of aprotinin when celite and kaolin are used as activators but not when tissue factor is the activator.


2013 ◽  
Vol 58 (2) ◽  
Author(s):  
Isabel Ribeiro ◽  
Antônio Câmara ◽  
Marta Bittencourt ◽  
Tatiana Marçola ◽  
Giane Paludo ◽  
...  

AbstractThis study aimed to determine whether asymptomatic horses naturally infected with Theileria equi retain infected erythrocytes in the spleen and whether the presence of the hemoparasite in this organ is associated with parasitemia. We collected samples from 25 adult horses without clinical signs of any disease. From each animal, we collected whole blood samples from the jugular vein and a splenic puncture blood sample. All samples were submited to blood cell counts and detection of Theileria or Babesia. DNA extraction and PCR were performed in all samples for identification of piroplasm infection (T. equi and B. caballi). From the 25 horses evaluated for piroplasm detection by PCR, seven horses (28%) were positive in jugular vein blood but negative in splenic blood samples, five horses (20%) were positive in splenic blood samples but negative in jugular vein blood samples, and 13 horses (52%) were positive in both jugular vein and splenic blood samples. The hematological evaluation revealed anemia in 13 of 25 (52%) infected horses, lymphopenia in five (20%), neutrophilia in two (8%), neutropenia in one (4%), and thrombocytopenia in one (4%) infected horse. The present study demonstrated that several (20%) of the asymptomatic piroplasm carrier horses did not show parasitemia, but show infected erythrocytes in the spleen.


Sign in / Sign up

Export Citation Format

Share Document