Rapid and Sensitive Liquid Chromatographic Method for Determination of Anastrozole in Different Polymer–Lipid Hybrid Nanoparticles

Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.

2019 ◽  
Vol 9 (18) ◽  
pp. 3711 ◽  
Author(s):  
Md Abdul Wazed ◽  
Mohammed Farid

Osteopontin (OPN) is a multifunctional whey protein which has recently received much attention for possibly applications in fortifying infant milk formula (IMF) with its bioactivity. However, to date, there is no established high-performance liquid chromatography (HPLC) method to quantify this protein in milk or IMF. In this study, a rapid, simple, isocratic and reliable reversed-phase HPLC method was developed and validated to quantify the OPN in IMF. A C18 column (4.6 × 150 mm × 5 micron) was employed with 20% of 0.1% trifluoroacetic acid (TFA) and 80% of 60% acetonitrile in 0.1% TFA for 10 min detected at 214 nm. The flow rate was 0.3 mL/min with an injection volume of 10 µL. The column temperature was 40 °C, and the peak appeared after 4 min. The validation was based on the system suitability, linearity (r2 = 0.999), limit of detection (LOD) (0.14 mg/L), limit of quantitation (LOQ) (0.41 mg/L), precision (% relative standard deviation (RSD) < 0.2), recovery (% RSD < 3) and robustness. The results confirm that the method developed is suitable for OPN determination in IMF.


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


Author(s):  
PULAGURTHA BHASKARARAO ◽  
GOWRI SANKAR DANNANA

Objective: Noscof tablet is a fixed dosage combination formulation having diphenhydramine (DH), ephedrine (ED), noscapine (NP), and glycerol glycolate (GG). A sensitive, selective, accurate, precise, and stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method with photodiode array detection has been developed and validated for simultaneous analysis of DH, ED, NP, and GG in bulk drug and Noscof tablets. Methods: Reversed-phase chromatographic separation and analysis of DH, ED, NP, and GG were done on an Altima C18 column with 0.01 M KH2PO4 buffer (pH 3.5) and acetonitrile (50:50%, v/v) as mobile phase at 0.8 ml/min flow rate in isocratic mode. Detection was performed at 260 nm. The method was validated in harmony with International Conference on Harmonization (ICH) guidelines. The tablet sample solution was subjected to diverse stress conditions using ICH strategy such as hydrolytic degradation (neutral - with distilled water, alkaline - with 2 N NaOH, and acidic - with 2 N HCl), oxidation (with 10% H2O2), photodegradation (exposing to UV light), and dry heat degradation (exposing to 105°C). Results: Using the above stated chromatographic conditions, sharp peaks were obtained for ED, NP, DH, and GG with retention time of 3.272 min, 4.098 min, 5.467 min, and 6.783 min, respectively. Good regression coefficient values were obtained in the range of 2–12 μg/ml for ED, 3.75–22.5 μg/ml for NP, 3.125–18.75 μg/ml for DH, and 25–150 μg/ml for GG. The quantification limits were 0.181 μg/ml, 0.187 μg/ml, 0.246 μg/ml, and 1.114 μg/ml for ED, NP, DH, and GG, respectively. The values of validation parameters are within the acceptance limits given by ICH. The ED, NP, DH, and GG showed more percent of degradation in acid condition and less percent of degradation in the neutral condition. The peaks of degradants did not interfere with the peaks of analytes. ED, NP, DH, and GG were assessed with a good percentage of the assay (near to 100%) and low percent relative standard deviation (<2%) in Noscof tablets using the proposed method. Conclusion: The stability indicating RP-HPLC method developed was suitable for quantifying ED, NP, DH, and GG simultaneously in bulk as well as in tablet formulation.


2008 ◽  
Vol 91 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanolwater (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 g/mL. The values for interday and intraday precision (relative standard deviation) were &lt;1. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.


2007 ◽  
Vol 90 (3) ◽  
pp. 720-724
Author(s):  
Sevgi Tatar Ulu

Abstract A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-Cl). A mobile phase consisting of acetonitrile10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were &lt;0.46 and &lt;0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.


Author(s):  
Kanan G Gamit ◽  
Niraj Y Vyas ◽  
Nishit D Patel ◽  
Manan A Raval

Objective: A study was aimed to estimate guggulsterone-Z (GZ) in Gokshuradi Guggulu (GG).Methods: An analytical method was developed and validated using Waters Alliance high-performance liquid chromatography system (Empower software), equipped with photodiode array detector. Separation was achieved using Phenomenex, C-18 (250 mm×4.6 mm, 5 μ) column. Mobile phase consisted of acetonitrile:water (70:30,v/v). Flow rate was set to 1 ml/min and detection was performed at 251 nm.Results and Discussion: Validation parameters such as linearity, precision, accuracy, limit of detection, limit of quantification, and robustness were performed. Amount of GZ was estimated using linearity equation.Conclusion: GG was found to contain 0.815±0.03 g% w/w GZ. Validated method may be used as one of the parameters to standardize the formulation.


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


Author(s):  
M. VIJAYA KUMARI ◽  
CH. BALASEKHAR REDDY

Objective: An accurate, rapid economical and straight forward, reliable assay technique was evolved and showed for the evaluation of zanubrutinib using reversed-phase high-performance liquid chromatography. Methods: In the proposed method, efficient chromatographic separation was achieved applying acetonitrile and 0.1% orthophosphoric acid (50:50 v/v) as a mobile phase with a flow of 1 ml/min and the wavelength was observed at 220 nm. Chromatography was administered isocratically at ambient temperature and run time was approximately 6 min and the retention time (Rt) was observed as 4.358 min. Results: The method was justified as per ICH guidelines. System suitability parameters were studied by injecting the quality six fold and results were well under acceptance criteria. Linearity study was administered between 10% and 150% levels, regression coefficient value was observed as 0.999. Limit of detection and limit of quantification were observed as 0.02 μg/ml and 0.2 μg/ml, respectively. Precision was found to be 0.74 for repeatability and 0.68 for intermediate precision. Recovery of the drug was found to be 98–102%, indicates that the recovery is in the acceptable limit. Validation results were found to be satisfactory and the method applicable for bulk and formulation analysis. Hence, it was evident that the proposed method was said to be suitable for regular analysis and quality control of pharmaceutical preparations. Conclusion: The validation results were in good agreement with the acceptable limit. Relative standard deviation values which are <2.0% indicating the accuracy and precision of this method. Assay of retail formulation was administered and found to be 100.24% was present using the above method. Stress conditions of degradation in acidic, alkaline, peroxide, and thermal were studied. This developed method showed reliable, precise, accurate results under optimized conditions.


Sign in / Sign up

Export Citation Format

Share Document