Study of energy dissipation capacity of steel beams under cyclic loading

2020 ◽  
Vol 23 (13) ◽  
pp. 2822-2834
Author(s):  
Xian Rong ◽  
Hongwei Yang ◽  
Jianxin Zhang

This article investigated the seismic performance of a new type of precast concrete beam-to-column joint with a steel connector for easy construction. Five interior beam-to-column joints, four precast concrete specimens, and one monolithic joint were tested under reversed cyclic loading. The main variables were the embedded H-beam length, web plate or stiffening rib usage, and concrete usage in the connection part. The load–displacement hysteresis curves were recorded during the test, and the behavior was investigated based on displacement ductility, deformability, skeleton curves, stiffness degradation, and energy dissipation capacity. The results showed that the proposed beam-to-column joint with the web plate in the steel connector exhibited satisfactory behavior in terms of ductility, load capacity, and energy dissipation capacity under reversed cyclic loading, and the performance was ductile because of the yielding of the web plate. Therefore, the proposed joint with the web plate could be used in high seismic regions. The proposed joint without the web plate exhibited similar behavior to the monolithic specimen, indicating that this joint could be used in low or moderate seismic zones. Furthermore, the utilization of the web plate was vital to the performance of this system.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Qiang Zhou ◽  
Lingyu Yang ◽  
Wenyang Zhao

Masonry structures are widely used in developing countries due to their low cost and simple construction, especially in remote areas, where there are a large number of houses without seismic measures. These buildings are prone to collapse and cause a lot of casualties, even under the action of small earthquakes. For the reinforcement of this structure, a cheap, effective, and easy-to-construct reinforcement method is urgently needed. Therefore, this article studies the reinforcement method of polypropylene bands (PP-bands). We have carried out low-frequency cyclic loading tests for two PP-band reinforced masonry walls and two compared masonry walls. We mainly studied the influence of PP-band and different compressive strengths of plastering mortar on the masonry wall’s seismic capacity. The seismic indicators mainly studied in this article include ultimate bearing capacity, energy dissipation capacity, stiffness degradation, and hysteresis characteristics. The experimental results show that the PP-band can greatly enhance the seismic capacity of the masonry wall. The ultimate bearing capacity, energy dissipation capacity, and displacement ductility of the PP-band reinforced wall are increased by 38%–48%, 22%–47%, and 138%–226%.


2016 ◽  
Vol 16 (01) ◽  
pp. 1640015 ◽  
Author(s):  
Yun Tian Wu ◽  
Yu Shan Fu ◽  
Chong-Ming Dai

A new type of partially steel tubed concrete (PSTC) column is proposed that is suitable to be used in new high rise reinforced concrete (RC) buildings. Three exterior joint specimens consisting of RC beams and PSTC columns and two exterior RC joint specimens were designed and tested under high axial load and cyclic loading to investigate the joint behavior in terms of failure pattern, hysteresis response, deformation, energy dissipation capacity and degradation of strength and stiffness. Test results indicate that the PSTC column can benefit the performance of the joint in terms of strength, ductility and energy dissipation capacity and can partly compensate for the unfavorable effect induced by slab. The strong column–weak beam mechanism can also be ensured in RC beam to PSTC column joint.


2021 ◽  
Vol 2021 ◽  
pp. 1-20
Author(s):  
Haian Liang ◽  
Hao Zeng ◽  
Kaiwei Cao ◽  
Chao Liu ◽  
Xinjun Cheng

In order to study the cumulative damage and failure characteristics of long spiral belled pile under horizontal cyclic loading of offshore wind and waves, a series of indoor experiments on single piles under horizontal cyclic load were carried out. The cycle times as well as load amplitude at the same frequency were considered during the horizontal pseudo-static cyclic tests. On the basis of the distribution of pile deflection, bending moment, and Earth pressure around the pile, the pile-soil interaction was comprehensively discussed. The cumulative energy dissipation characteristics were introduced to describe the damage of test piles. Meanwhile, the effects of load amplitude and cycle times on the cumulative damage of long spiral belled piles were discussed. A power function model for energy dissipation coefficient prediction under multi-stage cyclic load was proposed. The results show that the horizontal peak bearing capacity of long spiral belled pile is increased by 57.2% and 40.4%, respectively, as compared with the straight pile and belled pile under the same conditions. The horizontal displacement mainly occurs at the upper part of the pile. Under the condition of limited cyclic times, the load amplitude has more significant effect on the bearing characteristics of the long spiral belled pile. In contrast to the straight pile and belled pile, the long spiral belled pile has better energy dissipation capacity, and the rank of the energy dissipation capacity of these three piles is long spiral belled pile > belled pile > straight pile. The power function model can well reflect the cumulative damage characteristics of long spiral belled pile under horizontal cyclic loading, and there is a good linear relationship between power function model parameters and load amplitude. The energy dissipation coefficient of long spiral belled pile with diverse cycle times at different mechanical stages of test pile is analysed. Then, the recommended power function model parameters according to different failure stages are proposed. The verification example indicates that the prediction results are close to the measured values with a calculation error of 22%. The prediction model can provide a certain reference for the application of long spiral belled pile in marine structures.


2020 ◽  
Vol 2020 ◽  
pp. 1-16
Author(s):  
Lianjie Jiang ◽  
Guoliang Bai

The cumulative damage behavior of SRC columns under far-field long-period ground motions was simulated and studied by quasi-static tests with the same displacement for 10 times. Quasi-static tests of 8 SRC columns were conducted under the horizontal cyclic loading with the same displacement for 10 times or 3 times, and then the effects of steel ratio, stirrup ratio, axial compression ratio, and number of cyclic loading on the cumulative damage of SRC columns under the far-field long-period ground motions were studied. The results showed that the number of cyclic loading had little effect on the peak load of the specimens, but had a significant effect on the deformation capacity, stiffness degradation, and energy dissipation capacity. Compared with the specimens after 3 cycles, the displacement ductility coefficient of specimens after 10 cycles was reduced by about 20%–26%, the ultimate hysteresis energy dissipation was reduced by 35%–48%, while the stiffness degradation rate was accelerated. After the peak load, the cumulative damage caused by multiple cyclic loading with the same displacement was more significant, which aggravated the reduction of bearing capacity and stiffness degradation. The smaller the steel ratio and stirrup ratio, the larger the axial compression ratio, and the greater the reduction of the bearing capacity and stiffness of specimens. However, accumulated damage caused by multiple cyclic loading with the same displacement had a slight impact on the energy dissipation capacity. Increasing the steel ratio and stirrup ratio can effectively improve the deformation capacity and energy dissipation capacity of the specimens and reduce the bearing capacity and stiffness degradation caused by cumulative damage.


2013 ◽  
Vol 275-277 ◽  
pp. 947-950
Author(s):  
Kun Liu ◽  
Jing Xian Tian ◽  
Yan Yan Li

Three L-shaped columns with HRB500 reinforcement were tested under low cyclic loading. The effect of stirrup ratios on damage characteristic, hysteretic characteristic, rigidity degradation and energy dissipation capacity was analyzed to research the hysteretic behavior of L-shaped columns with HRB500 reinforcement. The result shows that the damage characteristic and the hysteretic characteristic of L-shaped columns with HRB500 reinforcement are improved with the increase of stirrup ratios. The energy dissipation capacity of L-shaped column was also enhanced after ultimate load with the increase of stirrup ratios.


2012 ◽  
Vol 256-259 ◽  
pp. 2079-2084 ◽  
Author(s):  
Tie Cheng Wang ◽  
An Gao ◽  
Hai Long Zhao

The influence of the pile type and the stirrup on the seismic performance was evaluated based on the results of reversed cyclic loading tests on the four prestressed high strength concrete (PHC) piles. It is indicated that the AB-type pile has the better seismic performance than the A-type pile from the results. The bearing capacity does not increase obviously with decreasing of the stirrup spacing and increasing of the stirrup diameter. The degradation of stiffness does not decrease significantly with decreasing of the stirrup spacing and increasing of the stirrup diameter. The energy dissipation capacity is improved with increasing of the stirrup diameter and decreasing of the stirrup spacing.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Yue Li ◽  
Qiqi Wu

To fully ascertain the ultimate shear failure state and the friction sliding performance of laminated rubber bearings in bridges, a series of cyclic loading tests were conducted. The energy dissipation characteristics of the laminated rubber bearings with two end plates, rubber bearings with unilateral friction sliding, and lead rubber bearing (LRB) under low-frequency cyclic loads were compared and analyzed. The results showed the following. (1) The ultimate shear deformation of the rubber bearings with two end plates could reach 300% to 400% of the rubber layer thickness. The energy dissipation capacity of the bearings was weak, and the hysteresis curves presented narrow zonal shapes. (2) The rubber bearings with unilateral friction sliding had similar energy dissipation capacities compared to the LRB. With the increase of the sliding distance, the dissipated energy continuously enlarged. The shear deformation of the bearing was no longer increased after reaching the maximum. After the test, the bearings remained in a good condition. The hysteresis curves of the load and displacement presented bilinear shapes. (3) Under the cyclic loading, the energy dissipation capacity of LRB was stable. The hysteresis curves of LRB were always fuller than the laminated rubber bearings.


Sign in / Sign up