Design of enterprises of sugar and starch industries

Author(s):  
Анатолий Славянский ◽  
Anatoliy Slavyanskiy

In the textbook on the example of sugar and starch-treacle industries of the food industry, the main issues of design and organization of construction and reconstruction of the food industry. A large reference material on various aspects of enterprise design is given. There are recommendations on the organization of work of students (bachelors and masters) on the diploma project and its design

Author(s):  
Jean Fincher

An important trend in the food industry today is reduction in the amount of fat in manufactured foods. Often fat reduction is accomplished by replacing part of the natural fat with carbohydrates which serve to bind water and increase viscosity. It is in understanding the roles of these two major components of food, fats and carbohydrates, that freeze-fracture is so important. It is well known that conventional fixation procedures are inadequate for many food products, in particular, foods with carbohydrates as a predominant structural feature. For some food science applications the advantages of freeze-fracture preparation procedures include not only the avoidance of chemical fixatives, but also the opportunity to control the temperature of the sample just prior to rapid freezing.In conventional foods freeze-fracture has been used most successfully in analysis of milk and milk products. Milk gels depend on interactions between lipid droplets and proteins. Whipped emulsions, either whipped cream or ice cream, involve complex interactions between lipid, protein, air cell surfaces, and added emulsifiers.


2013 ◽  
Author(s):  
Ted Scharf ◽  
Charles Vaught ◽  
Kathleen Kowalski-Trakofler ◽  
Ross Pastel ◽  
Donald Elisburg ◽  
...  

2013 ◽  
Author(s):  
Susan McCrone ◽  
Claire Caruso ◽  
David Weissman

1991 ◽  
Vol 65 (03) ◽  
pp. 263-267 ◽  
Author(s):  
A M H P van den Besselaar ◽  
R M Bertina

SummaryIn a collaborative trial of eleven laboratories which was performed mainly within the framework of the European Community Bureau of Reference (BCR), a second reference material for thromboplastin, rabbit, plain, was calibrated against its predecessor RBT/79. This second reference material (coded CRM 149R) has a mean International Sensitivity Index (ISI) of 1.343 with a standard error of the mean of 0.035. The standard error of the ISI was determined by combination of the standard errors of the ISI of RBT/79 and the slope of the calibration line in this trial.The BCR reference material for thromboplastin, human, plain (coded BCT/099) was also included in this trial for assessment of the long-term stability of the relationship with RBT/79. The results indicated that this relationship has not changed over a period of 8 years. The interlaboratory variation of the slope of the relationship between CRM 149R and RBT/79 was significantly lower than the variation of the slope of the relationship between BCT/099 and RBT/79. In addition to the manual technique, a semi-automatic coagulometer according to Schnitger & Gross was used to determine prothrombin times with CRM 149R. The mean ISI of CRM 149R was not affected by replacement of the manual technique by this particular coagulometer.Two lyophilized plasmas were included in this trial. The mean slope of relationship between RBT/79 and CRM 149R based on the two lyophilized plasmas was the same as the corresponding slope based on fresh plasmas. Tlowever, the mean slope of relationship between RBT/79 and BCT/099 based on the two lyophilized plasmas was 4.9% higher than the mean slope based on fresh plasmas. Thus, the use of these lyophilized plasmas induced a small but significant bias in the slope of relationship between these thromboplastins of different species.


1994 ◽  
Vol 72 (01) ◽  
pp. 084-088 ◽  
Author(s):  
E M Duncan ◽  
C R Casey ◽  
B M Duncan ◽  
J V Lloyd

SummaryThe aim of this study was to determine whether the concentration of trisodium citrate used to anticoagulate blood has an effect on the INR of the sample and the ISI of the thromboplastin. Five thromboplastins including and Australian reference material were used to measure the prothrombin time of normal and patient samples collected into two concentrations of trisodium citrate - 109 mM and 129 mM. There was no effect of citrate concentration on the INRs determined with the reference material. However for the other four thromboplastins there was a significant difference between INRs for the two citrate groups. The prothrombin times of the samples collected into 129 mM were longer than those collected into 109 mM. This difference was only slight in normal plasma but more marked in patients receiving oral anticoagulants, causing the INRs for patient plasmas collected into 129 mM citrate to be higher then the corresponding samples collected into 109 mM citrate.From orthogonal regression of log prothrombin times by the reference method against each thromboplastin, we found that the ISI for each thromboplastin was approximately 10% lower when determined with samples collected into 129 mM citrate than with samples collected into 109 mM. These results suggest that the concentration of trisodium citrate used for collection of blood samples can affect the calculation of the INR and the calibration of the ISI of thromboplastin. This was found both for commercial thromboplastins prepared by tissue extraction and for a recombinant tissue factor.


Sign in / Sign up

Export Citation Format

Share Document