scholarly journals Decay time characteristics of La_2O_2S:Eu and La_2O_2S:Tb for use within an optical sensor for human skin temperature measurement

2008 ◽  
Vol 47 (27) ◽  
pp. 4895 ◽  
Author(s):  
Sook Voon Yap ◽  
Robert M. Ranson ◽  
Wayne M. Cranton ◽  
Demosthenes Koutsogeorgis
2009 ◽  
Vol 31 (1) ◽  
pp. 95-114 ◽  
Author(s):  
A D Harper Smith ◽  
D R Crabtree ◽  
J L J Bilzon ◽  
N P Walsh

Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4101
Author(s):  
Nikolai B. Suvorov ◽  
Alexander V. Belov ◽  
Konstantin G. Kuliabin ◽  
Aleksei A. Anisimov ◽  
Timofei V. Sergeev ◽  
...  

This paper describes the experimental results of testing a prototype of a high precision human skin rapid temperature fluctuations measuring instrument. Based on the author’s work, an original circuit solution on a miniature semiconductor diode sensor has been designed. The proposed circuitry provides operation in the full voltage range with automatic setting and holding the operating point, as well as the necessary slope of the conversion coefficient (up to 2300 mV/°C), which makes it possible to register fast temperature oscillations from the surface of the human body and other biological objects. Simulation results in the Microcap 12 software and laboratory tests have confirmed all declared design specifications: temperature resolution of 0.01 °C, transducer thermal time constant of 0.05 s. An original thermostat and an experimental setup for the simultaneous registration of the electrocardiogram, pulse wave signals from the Biopac polygraph MP36 and a signal of temperature oscillations from the prototype thermometer have been designed for further investigations. The preliminary test results indicates that using the designed measuring instrument gives a possibility to provide an in-depth study of the relationship between micro- and macro-blood circulations manifested in skin temperature fluctuations.


1934 ◽  
Vol 30 (10) ◽  
pp. 1049-1050
Author(s):  
I. Johs

Skin temperature depends mainly on the amount of incoming blood and is of great practical importance. In limb artery embolism the skin temperature reveals a large difference on the healthy and diseased limb. In doubtful cases this symptom allows a diagnosis to be made after 1-2 hours and a timely operation to be undertaken.


2019 ◽  
Vol 1 (3) ◽  
pp. 1-4
Author(s):  
Zaina Norhallis Zainol ◽  
Masine Md. Tap ◽  
Haslinda Mohamed Kamar

Thermal comfort is the human subject perceive satisfaction to the work environment. The thermal comfort need to be achieve towards productive working environment. The comfort level of the subject is affected by the human skin temperature. To assess the skin temperature with the sorrounding by conducting human experiment in the climatic chamber. It is rigorous and complex experiment.This study was developed to predict human skin temperature in comfort level with the finite element method and the bioheat equation. The bioheat equation is a consideration of metabolic heat generation and the blood perfusion to solve heat transfer of the living tissue. It is to determine the skin temperature focussing at the human arm. From the study, it is found that the predicted skin temperature value were in well agreement with the experimental results. The percentage error insignificant with acceptable error of 1.05%.