scholarly journals Evaluation of metallic brackets adhesion after the use of bleaching gels with and without amorphous calcium phosphate (ACP): in vitro study

2013 ◽  
Vol 18 (3) ◽  
pp. 101-106 ◽  
Author(s):  
Sissy Maria Mendes Machado ◽  
Diego Bruno Pinho do Nascimento ◽  
Robson Costa Silva ◽  
Sandro Cordeiro Loretto ◽  
David Normando

OBJECTIVE: To evaluate in vitro the effects of tooth whitening using gel with Amorphous Calcium Phosphate (ACP) on the bond strength of metal brackets. METHODS: Thirty-six bovine incisors were sectioned at the crown-root interface, and the crowns were then placed in PVC cylinders. The specimens were divided into 3 groups (n = 12) according to whitening treatment and type of gel used, as follows: G1 (control) = no whitening; G2 = whitening with gel not containing ACP (Whiteness Perfect - FGM), G3 = whitening with gel containing ACP (Nite White ACP - Discus Dental). Groups G2 and G3 were subjected to 14 cycles of whitening followed by an interval of 15 days before the bonding of metal brackets. Shear bond strength testing was performed on a Kratos universal test machine at a speed of 0.5 mm/min. After the mechanical test, the specimens were assessed to determine the adhesive remnant index (ARI). The results were subjected to ANOVA, Tukey's test and Kruskal-Wallis test (5%). RESULTS: Significant differences were noted between the groups. Control group (G1 = 11.10 MPa) showed a statistically higher shear bond strength than the groups that underwent whitening (G2 = 5.40 Mpa, G3 = 3.73 MPa), which did not differ from each other. There were no significant differences between the groups in terms of ARI. CONCLUSION: Tooth whitening reduces the bond strength of metal brackets, whereas the presence of ACP in the whitening gel has no bearing on the results.

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Andreas Hellak ◽  
Jennifer Ebeling ◽  
Michael Schauseil ◽  
Steffen Stein ◽  
Matthias Roggendorf ◽  
...  

Objective.The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™.Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces,n=30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05).Results. Significant differences in SBS and ARI were found between the control group and experimental groups.Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.


2021 ◽  
Vol 24 (2) ◽  
pp. 143
Author(s):  
KommineniHarika Chowdary ◽  
Bolla Nagesh ◽  
PraveenKumar Gali ◽  
Tammineedi Sravanthi ◽  
LakshmiBhavani Potru ◽  
...  

2019 ◽  
Vol 13 (1) ◽  
pp. 255-260
Author(s):  
Francisco Molina ◽  
Karina Maria Salvatore Freitas ◽  
Maria Cristina Rockenbach Binz Ordóñez ◽  
Emerson Flamarion Cruz ◽  
Rafael Pinelli Henriques ◽  
...  

Objective: The objective of this study was to evaluate in vitro the shear bond strength of two types of MIM (Metal Injection Molding) technology brackets, one with conventional mesh base and the other with rail-shaped mesh base. Materials and Methods: Forty human premolars received the bonding of 2 types of brackets: Group 1- 20 Synergy metal brackets (Rocky Mountain) with conventional mesh base and Group 2-20 H4 brackets (OrthoClassic) with rail-shaped mesh base. Both brackets were bonded with Resilience photopolymerizable resin (OrthoTechnology). The specimens were coupled to a Tinius Olsen universal test machine where the shear test was performed using a chisel. In addition, the amount of remaining resin in tooth crown with the ImageJ program was evaluated and the Adhesive Remnant Index (ARI). Intergroup comparison was performed by the independent t test and Chi-square test. Results: There was no statistically significant difference between the groups for any of the measures evaluated indicating that the mesh type of the brackets’ base with MIM technology did not influence the shear bond strength of the brackets (shear bond strength, p=0.191; maximum load registered, p=0.244). There was also no difference between the percentage (p=0.602) and area of remaining resin in the teeth (p=0.805) and IRA (p=0.625) between the Synergy and H4 groups. Conclusion: Shear bond strength was similar in the two types of brackets with MIM technology evaluated. In addition, the remaining resin in the dental enamel of two types of brackets were also similar.


2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Homa Farhadifard ◽  
Loghman Rezaei-Soufi ◽  
Maryam Farhadian ◽  
Parisa Shokouhi

Abstract Background At present, the demand for orthodontic treatment is on the rise. On the other hand, evidence shows that the bond strength of composite resins to old composite restorations is often unreliable. Therefore, the aim of this in vitro study was to assess the effect of different surface treatments on shear bond strength (SBS) of ceramic brackets to old composite restorations. Methods In this in vitro experimental study, 60 nano-hybrid composite discs were fabricated. For aging, the discs were incubated in deionized water at 37 °C for 1 month. Next, they underwent 4 different surface treatments namely acid etching with 37% phosphoric acid, sandblasting, grinding, and Er,Cr:YSGG laser irradiation. Ceramic brackets were then bonded to the discs and underwent SBS testing. Results The maximum mean SBS value was obtained in the grinding group (9.16 ± 2.49 MPa), followed by the sandblasting (8.13 ± 2.58 MPa) and laser (6.57 ± 1.45 MPa) groups. The minimum mean SBS value was noted in the control group (5.07 ± 2.14 MPa). Conclusion All groups except for the control group showed clinically acceptable SBS. Therefore, grinding, sandblasting, and Er,Cr:YSGG laser are suggested as effective surface treatments for bonding of ceramic orthodontic brackets to aged composite.


2021 ◽  
Author(s):  
Ladan Ranjbar Omrani ◽  
Saba Tohidkhah ◽  
Elham Ahmadi ◽  
Mahdi Abbasi ◽  
Reza Morvaridi Farimani

Abstract Background: The aim of the current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.


2021 ◽  
pp. 232020682110502
Author(s):  
İdris Kavut ◽  
Mehmet Uğur

Aim: The aim of this study was to evaluate the effect of calcium phosphate based desensitizing agent on shear bond strength of self-etch/adhesive resin cements to dentin. Materials and Methods: Eighty dentin specimens were prepared from freshly extracted human third molar teeth and were classified, randomly ( n = 20). Half of groups were treated with calcium phosphate based Teethmate Desensitizer and then Panavia V5, RelyX Ultimate (containing self-etch primer), Panavia SA, and RelyX U200 self-adhesive resin cements were luted to all dentin surfaces. All specimens were stored in an incubator at 37°C for 24 h. Shear bond strength was tested by a universal test machine at a 0.5 mm/min crosshead speed. The data were analyzed with a statistical program. Two-way ANOVA was used for statistical differences ( P <.05). Dentin surfaces were examined with scanning electron microscopy (SEM) at x5000 and x10000 magnifications. Results: The higher shear bond values were observed in the groups with Teethmate Desensitizer applied and cemented with self-etch (16.05 ± 6.24 and 14.73 ± 4.75), whereas the lowest bonding values were observed in the groups with self-adhesive resin cement without Teethmate Desensitizer (3.73 ± 0.77 and 5.85 ± 4.19; P <.001). As the main effect of the treatment, the bond strength was 9.39 ± 6.04 in the control group, whereas it was 13.49 ± 5.44 in the Teethmate applied groups ( P <.05) Conclusions: Calcium phosphate desensitizer did not adversely effected shear bond strength of self-etch/adhesive resin cements to dentin. It even significantly increased the shear bond strength of self-adhesive resin cements.


Author(s):  
Zahra Khamverdi ◽  
Naemeh Karimian ◽  
Maryam Farhadian ◽  
Hamed Gheitouli

Objectives: Bond strength of composite restorations plays an important role in their success. This in vitro study evaluated the effect of a hemostatic agent on shear bond strength of universal adhesives. Materials and Methods: Thirty-six extracted human molars were used in this study. Buccal and lingual surfaces were reduced to obtain flat dentin surfaces and were ground with a silicone paper. The samples were randomly divided into three groups (n=12) based on the application of hemostatic agent: group 1: no contamination (control), group 2: aluminum chloride application, and group 3: ferric sulfate application. Each group was then divided into two subgroups (n=6) for using G-Premio and Single Bond Universal. Resin cylinders (Filtek Z550) were bonded to dentin surfaces according to the manufacturer’s instructions. After 1000 thermal cycles, shear load was applied to the specimens using a universal testing machine at a crosshead speed of 1 mm/min until failure. Data were statistically analyzed using two-way ANOVA and Tukey’s post-hoc test (α=0.05). Results: There were statistically significant differences in shear bond strength of the three main groups for both G-Premio and Single Bond Universal (P<0.05). When the adhesive systems were compared with each other, G-Premio showed higher shear bond strength than Single Bond Universal (P<0.05). Conclusion: Contamination with hemostatic agents had an adverse effect on the shear bond strength of universal adhesives. Moreover, G-Premio yielded a higher bond strength than Single Bond Universal.


Author(s):  
Mohammad Ali Mohammadi Torkani ◽  
Sepideh Mesbahi ◽  
Amir Ardalan Abdollahi

Objectives: This study aimed to assess the effect of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) on microtensile bond strength of three adhesive systems to deep dentin. Materials and Methods: In this in vitro study, the occlusal surface of 30 sound human third molars was sectioned at 2 mm below and above the cementoenamel junction. The samples were randomly divided into three groups of OptiBond Solo Plus, G-Bond, and Clearfil SE Bond. Before composite resin bonding, each group was divided into two subgroups with and without dentin preparation with CPP-ACP. The teeth were then sectioned into 1 mm rods (n=15), and their microtensile bond strength was measured at a crosshead speed of 0.5 mm/min. Data were analyzed using two-way ANOVA and post-hoc Bonferroni test. Results: There was no significant difference in bond strength of OptiBond Solo Plus (P=0.44) and Clearfil SE Bond (P=0.67) with/without CPP-ACP. A significant difference was found between the two subgroups of G-Bond in this respect (P<0.001). The differences in microtensile bond strength among all subgroups were significant (P<0.05). Conclusion: The microtensile bond strength in use of G-Bond is significantly higher following dentin treatment with CPP-ACP compared with no use of CPP-ACP.


2017 ◽  
Vol 22 (4) ◽  
pp. 53-60 ◽  
Author(s):  
Nasrin Farhadian ◽  
Loghman Rezaei-Soufi ◽  
Seyed Farzad Jamalian ◽  
Maryam Farhadian ◽  
Shahrzad Tamasoki ◽  
...  

ABSTRACT Introduction: Many patients seeking orthodontic treatment already have incipient enamel lesions and should be placed under preventive treatments. The aim of this in vitro study was to evaluate the effect of CPP-ACP paste and CO2 laser irradiation on demineralized enamel microhardness and shear bond strength of orthodontic brackets. Methods: Eighty caries-free human premolars were subjected to a demineralization challenge using Streptococcus mutans. After demineralization, the samples were randomly divided into five equal experimental groups: Group 1 (control), the brackets were bonded without any surface treatment; Group 2, the enamel surfaces were treated with CPP-ACP paste for 4 minutes before bonding; Group 3, the teeth were irradiated with CO2 laser beams at a wavelength of 10.6 µm for 20 seconds. The samples in Groups 4 and 5 were treated with CO2 laser either before or through CPP-ACP application. SEM photomicrographs of a tooth from each group were taken to observe the enamel surface. The brackets were bonded to the buccal enamel using a conventional method. Shear bond strength of brackets and ARI scores were measured. Vickers microhardness was measured on the non-bonded enamel surface. Data were analyzed with ANOVA and Tukey test at the p< 0.05 level. Results: The mean shear bond strength and microhardness of the laser group were higher than those in the control group and this difference was statistically significant (p< 0.05). All groups showed a higher percentage of ARI score 4. Conclusion: CO2 laser at a wavelength of 10.6 µm significantly increased demineralized enamel microhardness and enhanced bonding to demineralized enamel.


Sign in / Sign up

Export Citation Format

Share Document