scholarly journals Experimental Research On the Performance of a Novel Geo-Filament Anchor For An Earthen Architectural Site

Author(s):  
Wang Yulan ◽  
Guo Jian ◽  
Zhang Weixi ◽  
Lei Fan

Abstract An efficient anchoring method, explicitly developed for small sliders, has hitherto been missing in the practice of earthen architecture conservation. Furthermore, anchoring performance studies conducted so far, have failed to fully take into account the soil characteristics of certain targets. To address these concerns, the conservation project conceived for the Gaochang Ruins, Turpan, in China, was selected as the testing ground to design a novel Geotechnical Filament Anchor (GFA) for reinforcing small sliders in the earthen historical ramparts. In-situ experiments were conducted for evaluating six parameters—anchoring length (L), GF thickness (H), bore diameter (D), grouting strength (S), GFA surface status (R), and inclination angle (A). These parameters were varied in order to determine the effect they produce on anchoring performance, as demonstrated by the indicators, including tensile strength, destruction mode, load displacement (P-S) relation, and strain (ζ-L) distribution characteristics of the novel GFA. Data acquired from the experiments, in combination with the conservation specifics of earthen architectural sites, anchoring performance, and safety reserve, were further employed to introduce a calculation formula for computing the designed force value (N) through L. A simplified model depicting the shear stress distribution of the anchoring system under N was devised by extracting the strain distribution data with respect to the GF-grouting interface. Taking into account the soil properties of the above-mentioned site, the shear stress diffusion coefficient (α) was conceptualized, the formula for the shear strength of the grouting material was devised, and the tolerable ranges of L, D, H, R, and S were determined. Thus, a feasible anchoring method for small sliders used in earthen architectural sites is proposed, and validated by strong and reliable experimental and theoretical groundwork.

Author(s):  
M. A. Wall ◽  
M. E. Kassner

The metal fatigue phenomenon is poorly understood, partially because the dislocation dynamics of reversed deformation have not been well characterized. Little success has been realized with the direct observation of dislocations during in situ cyclic deformation. Problems associated with buckling of the specimen foil occur during applied shear, bending or compression. Buckling can preclude adequate imaging conditions and further complicate the thin foil stress-state. Recent experiments have shown that dislocation movement can be reversed by tensile stressing in alternate perpendicular directions (i.e. 90° rotation of the tensile stress to X and Y directions results in the reversal of the shear stress). Buckling of the specimen foil is also reduced in these experiments.Results from recent in situ reversed deformation experiments are presented here. The experiments were performed on a new straining stage which is a modification of the Sleeswyk- Kassner X-Y stage. The specimen design and preparation procedures have also been modified to facilitate better and more reproducible in situ experiments. The new X-Y straining stage is illustrated in figure 1.


Author(s):  
D. Loretto ◽  
J. M. Gibson ◽  
S. M. Yalisove ◽  
R. T. Tung

The cobalt disilicide/silicon system has potential applications as a metal-base and as a permeable-base transistor. Although thin, low defect density, films of CoSi2 on Si(111) have been successfully grown, there are reasons to believe that Si(100)/CoSi2 may be better suited to the transmission of electrons at the silicon/silicide interface than Si(111)/CoSi2. A TEM study of the formation of CoSi2 on Si(100) is therefore being conducted. We have previously reported TEM observations on Si(111)/CoSi2 grown both in situ, in an ultra high vacuum (UHV) TEM and ex situ, in a conventional Molecular Beam Epitaxy system.The procedures used for the MBE growth have been described elsewhere. In situ experiments were performed in a JEOL 200CX electron microscope, extensively modified to give a vacuum of better than 10-9 T in the specimen region and the capacity to do in situ sample heating and deposition. Cobalt was deposited onto clean Si(100) samples by thermal evaporation from cobalt-coated Ta filaments.


Author(s):  
Charles W. Allen ◽  
Robert C. Birtcher

The uranium silicides, including U3Si, are under study as candidate low enrichment nuclear fuels. Ion beam simulations of the in-reactor behavior of such materials are performed because a similar damage structure can be produced in hours by energetic heavy ions which requires years in actual reactor tests. This contribution treats one aspect of the microstructural behavior of U3Si under high energy electron irradiation and low dose energetic heavy ion irradiation and is based on in situ experiments, performed at the HVEM-Tandem User Facility at Argonne National Laboratory. This Facility interfaces a 2 MV Tandem ion accelerator and a 0.6 MV ion implanter to a 1.2 MeV AEI high voltage electron microscope, which allows a wide variety of in situ ion beam experiments to be performed with simultaneous irradiation and electron microscopy or diffraction.At elevated temperatures, U3Si exhibits the ordered AuCu3 structure. On cooling below 1058 K, the intermetallic transforms, evidently martensitically, to a body-centered tetragonal structure (alternatively, the structure may be described as face-centered tetragonal, which would be fcc except for a 1 pet tetragonal distortion). Mechanical twinning accompanies the transformation; however, diferences between electron diffraction patterns from twinned and non-twinned martensite plates could not be distinguished.


Author(s):  
Kenneth S. Vecchio ◽  
John A. Hunt

In-situ experiments conducted within a transmission electron microscope provide the operator a unique opportunity to directly observe microstructural phenomena, such as phase transformations and dislocation-precipitate interactions, “as they happen”. However, in-situ experiments usually require a tremendous amount of experimental preparation beforehand, as well as, during the actual experiment. In most cases the researcher must operate and control several pieces of equipment simultaneously. For example, in in-situ deformation experiments, the researcher may have to not only operate the TEM, but also control the straining holder and possibly some recording system such as a video tape machine. When it comes to in-situ fatigue deformation, the experiments became even more complicated with having to control numerous loading cycles while following the slow crack growth. In this paper we will describe a new method for conducting in-situ fatigue experiments using a camputer-controlled tensile straining holder.The tensile straining holder used with computer-control system was manufactured by Philips for the Philips 300 series microscopes. It was necessary to modify the specimen stage area of this holder to work in the Philips 400 series microscopes because the distance between the optic axis and holder airlock is different than in the Philips 300 series microscopes. However, the program and interfacing can easily be modified to work with any goniometer type straining holder which uses a penrmanent magnet motor.


1998 ◽  
Vol 37 (2) ◽  
pp. 137-144 ◽  
Author(s):  
Elisa Garvey ◽  
John E. Tobiason ◽  
Michael Hayes ◽  
Evelyn Wolfram ◽  
David A. Reckhow ◽  
...  

This paper reports on field studies and model development aimed at understanding coliform fate and transport in the Quabbin Reservoir, an oligotrophic drinking water supply reservoir. An investigation of reservoir currents suggested the importance of wind driven phenomena, and that both lateral and vertical circulation patterns exist. In-situ experiments of coliform decay suggested dependence on light intensity and yielded an appropriate decay coefficient to be used in CE-QUAL-W2, a two-dimensional hydrodynamic and water quality model. Modeling confirmed the sensitivity of reservoir outlet concentration to vertical variability within the reservoir, meteorological conditions, and location of coliform source.


2020 ◽  
Vol 154 (2) ◽  
pp. 135-153 ◽  
Author(s):  
Gabriel García Caballero ◽  
Donella Beckwith ◽  
Nadezhda V. Shilova ◽  
Adele Gabba ◽  
Tanja J. Kutzner ◽  
...  

Abstract The concept of biomedical significance of the functional pairing between tissue lectins and their glycoconjugate counterreceptors has reached the mainstream of research on the flow of biological information. A major challenge now is to identify the principles of structure–activity relationships that underlie specificity of recognition and the ensuing post-binding processes. Toward this end, we focus on a distinct feature on the side of the lectin, i.e. its architecture to present the carbohydrate recognition domain (CRD). Working with a multifunctional human lectin, i.e. galectin-3, as model, its CRD is used in protein engineering to build variants with different modular assembly. Hereby, it becomes possible to compare activity features of the natural design, i.e. CRD attached to an N-terminal tail, with those of homo- and heterodimers and the tail-free protein. Thermodynamics of binding disaccharides proved full activity of all proteins at very similar affinity. The following glycan array testing revealed maintained preferential contact formation with N-acetyllactosamine oligomers and histo-blood group ABH epitopes irrespective of variant design. The study of carbohydrate-inhibitable binding of the test panel disclosed up to qualitative cell-type-dependent differences in sections of fixed murine epididymis and especially jejunum. By probing topological aspects of binding, the susceptibility to inhibition by a tetravalent glycocluster was markedly different for the wild-type vs the homodimeric variant proteins. The results teach the salient lesson that protein design matters: the type of CRD presentation can have a profound bearing on whether basically suited oligosaccharides, which for example tested positively in an array, will become binding partners in situ. When lectin-glycoconjugate aggregates (lattices) are formed, their structural organization will depend on this parameter. Further testing (ga)lectin variants will thus be instrumental (i) to define the full range of impact of altering protein assembly and (ii) to explain why certain types of design have been favored during the course of evolution, besides opening biomedical perspectives for potential applications of the novel galectin forms.


Author(s):  
D.M. Seyedi ◽  
C. Plúa ◽  
M. Vitel ◽  
G. Armand ◽  
J. Rutqvist ◽  
...  

2021 ◽  
Author(s):  
Gopal Avashthi ◽  
Man Singh

Ultrasonochemically driven graphene oxide (GrO) functionalization (f) with Sulfanilamide (SA) near-edge catalyzed heterogeneous graphene oxide (h-GrO) as economic scalable f-(SA)GrO is reported. The novel in-situ H2O association was subsequently aligned...


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2102
Author(s):  
Breno G. P. Bezerra ◽  
Lindiane Bieseki ◽  
Mariele I. S. de Mello ◽  
Djalma R. da Silva ◽  
Cristiane B. Rodella ◽  
...  

In this memory effect study, hydrotalcite-type compounds in the lamellar double hydroxide-like (LDH)/zeolite A composite material were analyzed using X-Ray Diffration XRD) in situ experiments. Three samples were analyzed: Al,Mg-LDH, Al,Mg-LDH/ZA composite, and a physical mixture (50/50 wt%) of zeolite A and Al,Mg-LDH. The Al,Mg-LDH sample was treated at 500 °C in an O2 atmosphere and subsequently rehydrated. The Al,Mg-LDH/ZA composites had three treatments: one was performed at 300 °C in a He atmosphere, and two treatments were performed with an O2 atmosphere at 300 and 500 °C. In the physical mixture, two treatments were carried out under O2 flow at 500 °C and under He flow at 300 °C. Both went through the rehydration process. All samples were also analyzed by energy dispersive spectroscopy (EDS) and scanning electron microscopy (SEM). The results show that the LDH phase in the Al,Mg-LDH/ZA compounds has memory effects, and thus, the compound can be calcined and rehydrated. For the LDH in the composite, the best heat treatment system is a temperature of 300 °C in an inert atmosphere.


Sign in / Sign up

Export Citation Format

Share Document