scholarly journals Endovascular repair of aortic aneurysm: Preliminary results

2009 ◽  
Vol 137 (1-2) ◽  
pp. 10-17 ◽  
Author(s):  
Lazar Davidovic ◽  
Momcilo Colic ◽  
Igor Koncar ◽  
Dejan Markovic ◽  
Dusan Kostic ◽  
...  

Introduction. Endovascular aneurysm repair (EVAR) has been introduced into clinical practice at the beginning of the 90's of the last century. Because of economic, political and social problems during the last 25 years, the introduction of this procedure in Serbia was not possible. Objective. The aim of this study was to present preliminary experiences and results of the Clinic for Vascular Surgery of the Serbian Clinical Centre in Belgrade in endovascular treatment of thoracic and abdominal aortic aneurysms. Methods. The procedure was performed in 33 patients (3 female and 30 male), aged from 42 to 83 years. Ten patients had a descending thoracic aorta aneurysm (three atherosclerotic, four traumatic - three chronic and one acute as a part of polytrauma, one dissected, two penetrated atherosclerotic ulcers), while 23 patients had the abdominal aortic aneurysm, one ruptured and two isolated iliac artery aneurysms. The indications for EVAR were isthmic aneurismal localisation, aged over 80 years and associated comorbidity (cardiac, pulmonary and cerebrovasular diseases, previous thoracotomy or multiple laparotomies associated with abdominal infection, idiopatic thrombocitopaenia). All of these patients had three or more risk factors. The diagnosis was established using duplex ultrasonography, angiography and MSCT. In the case of thoracic aneurysm, a Medtronic-Valiant? endovascular stent graft was implanted, while for the abdominal aortic aneurysm Medtronic-Talent? endovascular stent grafts with delivery systems were used. In three patients, following EVAR a surgical repair of the femoral artery aneurysm was performed, and in another three patients femoro-femoral cross over bypass followed implantation of aortouniiliac stent graft. Results. During procedure and follow-up period (mean 1.6 years), there were: one death, one conversion, one endoleak type 1, six patients with endoleak type 2 that disappeared during the follow-up period, one early graft thrombosis. No other complications, including aneurysm expansion, collapse, deformity and migration of the endovascular stent grafts, were registered. Conclusion. According to all medical and economic aspects, we recommend EVAR to treat acute traumatic thoracic aortic aneurysm, as well as in elderly and high-risk patients with abdominal or thoracic aneurysms, when open surgery is related to a significantly higher mortality and morbidity.

Vascular ◽  
2020 ◽  
pp. 170853812096261
Author(s):  
Alessio Amico ◽  
David Russo ◽  
Francesco Benassi Franciosi ◽  
Debora Musio ◽  
Roberta de Prisco ◽  
...  

Objectives Abdominal aortic aneurysms with a wide proximal neck (>32 mm) are a contraindication for the use of conventional abdominal endovascular stent grafts because of their limited maximum proximal diameter (36 mm). In these cases, it is customary to resort to sophisticated techniques such as parallel or fenestrated grafts. In very selected cases, such as symptomatic wide neck aneurysm or patient with limited life expectancy, Funnel Technique may find an indication. Methods It consists in placing a bifurcated endograft in the abdominal aorta embricated with a thoracic endograft as a proximal cuff in an infrarenal position. Results In the literature review, we found 32 cases of this technique, whose characteristics are collected in a table. Conclusion The Funnel Technique, taking advantage of the larger diameters of the thoracic prostheses, may easily treat abdominal aortic aneurysm cases with a wide neck.


Vascular ◽  
2012 ◽  
Vol 21 (1) ◽  
pp. 10-13
Author(s):  
H T C Veger ◽  
P Ph Hedeman Joosten ◽  
S R Thoma ◽  
M J T Visser

Infection of endovascular abdominal aneurysm stent grafts is an uncommon but known complication. Inoculation with bacteria of the endovascular abdominal aneurysm stent graft during the actual implantation, in the periprocedural hospitalization or later due to an aortoenteric fistula, has been described in the literature. We report a case of endovascular abdominal aortic aneurysm stent graft infection occurring 40 months after implantation in a patient doing well up to an episode of urosepsis. In conclusion, we postulate that poor intraluminal healing of stent grafts, as observed in several explant studies, may result in a higher susceptibility to episodes of bacteremia than prosthetic vascular grafts inserted during open repair. We therefore consider the administration of prophylactic antibiotics in patients with endovascular stent grafts during periods with a likelihood of bacteremia.


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 620
Author(s):  
Muzammil H. Syed ◽  
Mark Wheatcroft ◽  
Danny Marcuzzi ◽  
Hooman Hennessey ◽  
Mohammad Qadura

The aim of this paper is to share our experience in managing a patient with Klebsiella pneumoniae mycotic abdominal aortic aneurysm who was also infected with COVID-19. A 69-year-old male was transferred to our hospital for the management of an infra-renal mycotic abdominal aortic aneurysm. During his hospital course, the patient contracted severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). He was intubated due to respiratory distress. Over a short period, his mycotic aneurysm increased in size from 2.5 cm to 3.9 cm. An emergency repair of his expanding aneurysm was achieved using our previously described protocol of coating endovascular stents with rifampin. The patient was managed with a rifampin-coated endovascular stent graft without any major complications. Postoperatively, the patient did not demonstrate any neurological deficits nor any vascular compromise. He remained afebrile during his postoperative course and was extubated sometime thereafter. He was then transferred to the ward for additional monitoring prior to his discharge to a rehab hospital while being on long-term antibiotics. During his hospital stay, he was monitored with serial ultrasounds to ensure the absence of abscess formation, aortic aneurysm growth or graft endoleak. At 6 weeks after stent graft placement, he underwent a CT scan, which showed a patent stent graft, with a residual sac size of 2.5 cm without any evidence of abscess or endoleak. Over a follow-up period of 180 days, the patient remained asymptomatic while remaining on long-term antibiotics. Thus, in patients whose surgical risk is prohibitive, endovascular stent grafts can be used as a bridge to definitive surgical management.


Vascular ◽  
2004 ◽  
Vol 12 (2) ◽  
pp. 106-113 ◽  
Author(s):  
William D. Jordan ◽  
Thomas C. Naslund ◽  
Mark A. Adelman ◽  
Gene Simoni ◽  
Douglas J. Wirthlin

Commercially available aortic stent grafts differ in construction and clinical advantage such that creating hybrid endografts by combining components from different manufacturers is sometimes useful. We describe a multicenter experience using hybrid endografts to treat patients with challenging anatomy. Hospital records and office charts were reviewed from four institutions. Hybrid endografts were defined as those with two types of covered stents in continuity to treat an abdominal aortic aneurysm (AAA). Indications for hybrid grafts were defined by type of endoleak and whether an endoleak was expected or unexpected as determined by the preoperative radiographic evaluation. Endpoints include intraoperative endoleaks, late endoleaks, change in aneurysm size, and rupture. Hybrid endografts were used to treat AAA (endovascular aneurysm repair [EVAR]) in 90 patients, representing 7.9% of the total multicenter experience. In 7 patients (7.8%), a hybrid graft construction as a secondary procedure successfully corrected a type 1 endoleak. In the remaining 83 patients (92.2%), hybrid grafts were created at the time of original EVAR to treat expected challenging anatomy or unexpected endoleaks. Hybrid endografts corrected 88 (97.8%) type 1 endoleaks, but 2 patients (2.2%) persisted with a proximal type 1 leak requiring conversion. During follow-up of 1 to 24 months, computed tomography and ultrasound surveillance, available for 73 patients (81.1%), detected one unresolved distal type 1 (1.1%) and seven type 2 (7.8%) endoleaks. Aneurysm size decreased at least 0.5 cm in 23 of 50 patients (46.0%) at 6 months and in 19 of 31 patients (61.3%) at 12 months. Aneurysm size increased at least 0.5 cm in 4 of 50 patients (8.0%) at 6 months and in 1 of 31 patients (3.2%) at 12 months. There were no ruptures. Hybrid endografts have favorable early and intermediate results in the treatment of AAA. Long-term follow-up will be needed to confirm the absence of significant adverse biomaterial interaction and the effect on AAA exclusion. We advocate the use of hybrid endografts as endovascular therapy for patients whose anatomy may be unsuitable for a single endograft type.


Vascular ◽  
2020 ◽  
pp. 170853812094505
Author(s):  
Mario D’Oria ◽  
Filippo Griselli ◽  
Davide Mastrorilli ◽  
Filippo Gorgatti ◽  
Silvia Bassini ◽  
...  

Objectives The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. Methods Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm. Results Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia. Conclusion Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique.


2012 ◽  
Vol 56 (2) ◽  
pp. 579
Author(s):  
Carlos E. Donayre ◽  
Faidzal Othman ◽  
George E. Kopchok ◽  
Ali Khoynezhad ◽  
Rodney A. White

Sign in / Sign up

Export Citation Format

Share Document