Different Methods for Inlay Production: Effect on Internal and Marginal Adaptation, Adjustment Time, and Contact Point

2017 ◽  
Vol 42 (4) ◽  
pp. 436-444 ◽  
Author(s):  
MP Rippe ◽  
C Monaco ◽  
L Volpe ◽  
MA Bottino ◽  
R Scotti ◽  
...  

SUMMARY The aim of this study was to evaluate the effect of different production methods of resin and ceramic inlays on marginal and internal adaptation, adjustment time, and proximal contacts. Forty premolars were selected, embedded (their roots), and prepared to receive inlays that were made as follows (n=10): LaRe—digital impression with a Lava C.O.S. scanner, followed by milling of Lava Ultimate block (composite resin) in a milling center; CeRe—digital impression with a Cerec 3D Bluecam scanner, followed by milling of Lava Ultimate block in Cerec; CeDis—digital impression with a Cerec 3D Bluecam scanner, followed by milling of IPS e.max CAD block (lithium disilicate) in Cerec; and PresDis—impression with polyvinyl siloxane, inlay made using the lost wax technique and IPS e.max Press pressed ceramic (lithium disilicate). Marginal and internal adaptations were measured using the replica technique. The inlay adjustments were performed using diamond burs in a contra-angle hand piece, and the time for adjustment was recorded using a timer, in seconds. The tightness of the proximal contact was measured using standardized metal blades. The statistical analyses for marginal fit data showed that at the cervical edge, CeDis (177.8 μm) had greater misfit than CeRe (116.7 μm), while all the groups had similar adaptation at the occlusal edge. The groups had similar internal fit at the pulpal wall, while LaRe (104.7 μm) > CeDis (66.7 μm) = CeRe (76.7 μm) at the axial wall. The groups restored with lithium disilicate ceramic took more time for adjustment when compared to the resin restorative material. The lowest proximal contact, in micrometers, was seen in the CeRe group (8.8 μm).

2018 ◽  
Vol 21 (3) ◽  
pp. 296
Author(s):  
Marília Pivetta Rippe ◽  
Elen Guerra ◽  
Arianne Vallim Pinto Coelho ◽  
Lilian Costa Anami ◽  
Renata Marques de Melo Marinho ◽  
...  

<p><strong>Objective:</strong> The aim of this study was to evaluate the internal and marginal adaptation of inlays fabricated from different types of impressions (conventional and digital) and different ceramics (feldspathic and lithium disilicate). <strong>Material and Methods:</strong> Forty premolars were prepared for all-ceramic inlay restoration and assigned to 4 groups (n=10), according to the impression method (conventional with addition silicone and digital impressions) and ceramic type (lithium disilicate and feldspathic ceramic blocks). For each type of impression, 10 inlays were fabricated from lithium disilicate blocks and the other 10 from feldspathic ceramic blocks, by means of the CAD-CAM system. The internal adaptation was analyzed by replica. The marginal fit was analyzed under a stereomicroscope by directly measuring the gap formed between the inlay and the tooth in the proximal and occlusal regions. <strong>Results:</strong> The marginal or internal adaptations were not affected by type of impression (conventional = digital impression), irrespective of the ceramic type. Only the internal adaptation was affected by material, i.e., feldspathic ceramic had lower values than disilicate ceramic, when considering the digital impression. <strong>Conclusion:</strong> The conventional and digital impressions promote similar marginal and internal adaptation of tested feldspathic and disilicate ceramic inlays. For digital impression the feldspathic ceramic showed better internal adaptation than lithium disilicate. </p><p><strong>Keywords</strong></p><p>Ceramics; Dental internal adaptation; Dental marginal adaptation; Dental impression technique.</p>


2017 ◽  
Vol 117 (3) ◽  
pp. 354-362 ◽  
Author(s):  
Marco Zeltner ◽  
Irena Sailer ◽  
Sven Mühlemann ◽  
Mutlu Özcan ◽  
Christoph H.F. Hämmerle ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Per Svanborg ◽  
Henrik Skjerven ◽  
Pablo Carlsson ◽  
Alf Eliasson ◽  
Stig Karlsson ◽  
...  

Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions.Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results.Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147 μm and 142 μm, cervical area discrepancy of 69 μm and 44 μm, and mean internal discrepancy of 117 μm and 93 μm. The differences were statistically significant in the cervical and internal areas (P<0.001).Significance. The results indicated that the digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.


2015 ◽  
Vol 24 (5) ◽  
pp. 381-386 ◽  
Author(s):  
David P. Alfaro ◽  
N. Dorin Ruse ◽  
Ricardo M. Carvalho ◽  
Chris C. Wyatt

Author(s):  
Brunna Mota Ferrairo ◽  
Fernanda Furtado Piras ◽  
Feranda Ferruzzi Lima ◽  
Heitor Marques Honório ◽  
Marco Antonio Hungaro Duarte ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document