Interlaboratory Groove Depth Measurements and Wear Estimation

1976 ◽  
Vol 4 (2) ◽  
pp. 59-65
Author(s):  
A. Kondo ◽  
F. C. Brenner

Abstract A tire was measured to determine its average groove depth by each of several operators in each of seven laboratories in the morning and afternoon for two consecutive days. The results show that the operators repeat their measurements within acceptable variation. On averages of six measurements by a single operator, a difference of 0.002 in. (0.05 mm) was significant. The variability of operators' averages around their laboratory average was the same for all laboratories except one. However, averages among laboratories were different, which is attributed to small differences in the measuring practice. The precision of wear rate estimates based on the difference of average groove depths before and after a period of wear is estimated and ways in which the precision of estimates of wear rates can be optimized are suggested.

1979 ◽  
Vol 7 (1) ◽  
pp. 31-39
Author(s):  
G. S. Ludwig ◽  
F. C. Brenner

Abstract An automatic tread gaging machine has been developed. It consists of three component systems: (1) a laser gaging head, (2) a tire handling device, and (3) a computer that controls the movement of the tire handling machine, processes the data, and computes the least-squares straight line from which a wear rate may be estimated. Experimental tests show that the machine has good repeatability. In comparisons with measurements obtained by a hand gage, the automatic machine gives smaller average groove depths. The difference before and after a period of wear for both methods of measurement are the same. Wear rates estimated from the slopes of straight lines fitted to both sets of data are not significantly different.


2011 ◽  
Vol 325 ◽  
pp. 339-344 ◽  
Author(s):  
Jim N. Boland ◽  
Xing S. Li ◽  
D. Hay ◽  
Colin M. MacRae ◽  
S. Elbracht ◽  
...  

Variability in the abrasive wear of PCD coatings on cemented WC substrates has been investigated. Six samples of PCD coated carbides were tested in a wear testing rig. The PCD coated element was used to turn an industry standard vitrified bonded corundum grinding wheel. The wear rate was measured as the weight loss of the cutting element per cubic metre of grinding wheel machined during the test. Two grades of cutting elements were observed. One grade had wear rates between 6 and 7.3 g/m³ but of the three poor quality samples, only one valid test was made realising wear rate of ~7,800 g/m³. The microstructures of the samples were studied using SEM, X-ray imaging, neutron diffraction and XRD. SEM images revealed differences in the volume percentage of diamonds in the two grades and the XRD scans highlighted the variable distribution of the diamond phase in the coating. Estimates of the residual stresses in a good and poor quality samples indicated significantly higher compressive stresses in the good quality versus poor quality coating. These results have revealed two extremes in the wear rates of these PCD coated carbides. It is suggested that the difference in diamond content between the two grades is not sufficient to account for the 3 orders-of-magnitude difference in the observed wear rates. However, the presence of intrusive veins of carbide material in the coatings, especially around the curved cutting tip, suggested that the macroscopic defects observed in the x-ray and SEM images were the major cause of the high wear rates in the poor quality sample.


1980 ◽  
Vol 8 (1) ◽  
pp. 13-19
Author(s):  
F. C. Brenner

Abstract During the early stages of tire wear, the wear rate determined from groove depth measurements may reflect a dimensional change not associated with rubber loss, that is superimposed on the tread loss. The combined effect can be fit with an exponential decay curve relating groove depth to miles run. A method for separating any shape change effect from wear rate effects is suggested.


2017 ◽  
Vol 65 (3) ◽  
pp. 191-195
Author(s):  
Jaqueline BRUSCHI ◽  
Luiza Bonezi BOFF ◽  
Tiago André Fontoura de MELO

ABSTRACT Objective To analyze cutting capacity, preparation time, and occurrence of apical deviation, after instrumentation of curved canals with reciprocating Primary WaveOne ® and R25 Reciproc ® systems. Methods Twenty simulated canals with 35° bends were randomly assigned to the Primary WaveOne ® or R25 Reciproc ® . The preparations were made by a single operator. The cutting capacity was assessed by the difference in weight (on an analytical balance) of the canals before and after preparation. The time needed for the preparation was analyzed. The canals were filled with India ink and photographed on a platform before and after the preparation to analyze the apical deviation to a 1 mm length. The images were superimposed in Photoshop ® and the measurement was performed with the ruler tool. Statistical analysis was performed using Student’s t-test. The level of significance was set at 5%. Results The WaveOne ® Primary system was more effective (in terms of cutting capacity) but had a longer preparation time than the R25 Reciproc ® instrument. Apical deviation was the only variable that did not significantly differ between the two systems. Conclusion The WaveOne ® Primary had a higher cutting capacity than the R25 Reciproc ® . Both systems maintained the original canal path. The preparation time was shorter for the R25 Reciproc ® than the WaveOne ® Primary system.


2016 ◽  
Vol 723 ◽  
pp. 220-223 ◽  
Author(s):  
Jae Young Byun ◽  
Pandusandi Pratama ◽  
Jeung Hoon Kim ◽  
In Soo Park ◽  
Sun Mi Choi ◽  
...  

The purpose of this study is to compare the frictions and wears characteristics of poly methyl methacrylate (PMMA) and MC Nylon. This study was carried out to investigate the material to be considered as the pad of spreading device material in the copper coil forming machine. To analyze the friction and wear characteristics of those materials the experiments were done as follows. Firstly, the friction characteristic was obtained using a pin-on-disk tester. The experiment was carried on dry and wet friction conditions under paraffin oil lubricant. Secondly, the state of lubrication was investigated using the Stribeck’s Curve. Thirdly, to investigate the wear characteristic, the weight of the pin was measured before and after the friction test. The wear rate is defined as the difference between the initial weight and the final weight. The experimental results show that the friction coefficient of PMMA material was higher than MC nylon. Furthermore, PMMA wear rate also higher than MC Nylon wear rate. The highest wear was achieved on PMMA in dry friction condition, which is 0.00290 grams. MC Nylon was recommended to be used as padding of the spreading device on the coil forming machine.


Author(s):  
R.A. Herring

Rapid thermal annealing (RTA) of ion-implanted Si is important for device fabrication. The defect structures of 2.5, 4.0, and 6.0 MeV As-implanted silicon irradiated to fluences of 2E14, 4E14, and 6E14, respectively, have been analyzed by electron diffraction both before and after RTA at 1100°C for 10 seconds. At such high fluences and energies the implanted As ions change the Si from crystalline to amorphous. Three distinct amorphous regions emerge due to the three implantation energies used (Fig. 1). The amorphous regions are separated from each other by crystalline Si (marked L1, L2, and L3 in Fig. 1) which contains a high concentration of small defect clusters. The small defect clusters were similar to what had been determined earlier as being amorphous zones since their contrast was principally of the structure-factor type that arises due to the difference in extinction distance between the matrix and damage regions.


1979 ◽  
Vol 42 (04) ◽  
pp. 1332-1339 ◽  
Author(s):  
Hiroh Yamazaki ◽  
Takeshi Motomiya ◽  
Minoru Sonoda ◽  
Noboru Miyagawa

SummaryChanges in platelets in 48 patients with uterine myoma before and after hysterectomy with and without ovariectomy were examined. Bilateral ovariectomy in 25 cases (ovariec-tomized group) and unilateral or non-ovariectomy in 23 cases (control group) were performed at the hysterectomy. Platelet count and an appearance rate of secondary aggregation decreased at one day after and increased at one week after the operation, similarly in both the ovariectomized and the control group. The appearance rate of secondary aggregation was reflected in an intensity of aggregation at 5 min after the addition of reagent to PRP. At one month after the operation, the appearance rate of secondary aggregation induced by 3 μM ADP showed a statistically significant decrease in comparison with the preoperation value (P <0.05) and the enhancement of 5-min aggregation was still observed in the control group, while ceased in the ovariectomized group. The difference between the two groups was significant (P < 0.05). There was almost no change in the speed and intensity of primary and secondary aggregation during the observation period. No significant differences in collagen-induced aggregation were noted between the two groups. The results suggest that ovarian hormones, mainly estrogen, facilitate platelet activation which is mediated by the so-called secondary aggregation.


Author(s):  
Niken Setyaningrum ◽  
Andri Setyorini ◽  
Fachruddin Tri Fitrianta

ABSTRACTBackground: Hypertension is one of the most common diseases, because this disease is suffered byboth men and women, as well as adults and young people. Treatment of hypertension does not onlyrely on medications from the doctor or regulate diet alone, but it is also important to make our bodyalways relaxed. Laughter can help to control blood pressure by reducing endocrine stress andcreating a relaxed condition to deal with relaxation.Objective: The general objective of the study was to determine the effect of laughter therapy ondecreasing elderly blood pressure in UPT Panti Wredha Budhi Dharma Yogyakarta.Methods: The design used in this study is a pre-experimental design study with one group pre-posttestresearch design where there is no control group (comparison). The population in this study wereelderly aged over> 60 years at 55 UPT Panti Wredha Budhi Dharma Yogyakarta. The method oftaking in this study uses total sampling. The sample in this study were 55 elderly. Data analysis wasused to determine the difference in blood pressure before and after laughing therapy with a ratio datascale that was using Pairs T-TestResult: There is an effect of laughing therapy on blood pressure in the elderly at UPT Panti WredhaBudhi Dharma Yogyakarta marked with a significant value of 0.000 (P <0.05)


2020 ◽  
Vol 22 (3) ◽  
pp. 341-361
Author(s):  
Gonzalo Grau-Pérez ◽  
J. Guillermo Milán

In Uruguay, Lacanian ideas arrived in the 1960s, into a context of Kleinian hegemony. Adopting a discursive approach, this study researched the initial reception of these ideas and its effects on clinical practices. We gathered a corpus of discursive data from clinical cases and theoretical-doctrinal articles (from the 1960s, 1970s and 1980s). In order to examine the effects of Lacanian ideas, we analysed the difference in the way of interpreting the clinical material before and after Lacan's reception. The results of this research illuminate some epistemological problems of psychoanalysis, especially the relationship between theory and clinical practice.


1962 ◽  
Vol 41 (1) ◽  
pp. 123-128 ◽  
Author(s):  
Pentti A. Järvinen ◽  
Sykkö Pesonen ◽  
Pirkko Väänänen

ABSTRACT The fractional determination of 17-ketosteroids in the daily urine was performed in nine cases of hyperemesis gravidarum and in four control cases, in the first trimester of pregnancy both before and after corticotrophin administration. The excretion of total 17-KS is similar in the two groups. Only in the hyperemesis group does the excretion of total 17-KS increase significantly after corticotrophin administration. The fractional determination reveals no difference between the two groups of patients with regard to the values of the fractions U (unidentified 17-KS), A (androsterone) and Rest (11-oxygenated 17-KS). The excretion of dehydroepiandrosterone is significantly higher in the hyperemesis group than in the control group. The excretion of androstanolone seems to be lower in the hyperemesis group than in the control group, but the difference is not statistically significant. The differences in the correlation between dehydroepiandrosterone and androstanolone in the two groups is significant. The high excretion of dehydroepiandrosterone and low excretion of androstanolone in cases of hyperemesis gravidarum is a sign of adrenal dysfunction.


Sign in / Sign up

Export Citation Format

Share Document