reciprocating systems
Recently Published Documents


TOTAL DOCUMENTS

62
(FIVE YEARS 23)

H-INDEX

10
(FIVE YEARS 3)

2022 ◽  
Vol 11 (2) ◽  
pp. 338
Author(s):  
Vicente Faus-Llácer ◽  
Dalia Pulido Ouardi ◽  
Ignacio Faus-Matoses ◽  
Celia Ruiz-Sánchez ◽  
Álvaro Zubizarreta-Macho ◽  
...  

The objective of the present study was to evaluate and compare the dentin removal capacity of Endogal Kids and Reciproc Blue NiTi alloy endodontic reciprocating systems for root canal treatments in primary second molar teeth via a micro-computed tomography (micro-CT) scan. Materials and Methods: Sixty root canal systems in fifteen primary second molar teeth were chosen and classified into one of the following study groups: A: EK3 Endogal Kids (n = 30) (EDG) and B. R25 Reciproc Blue (n = 30) (RB). Preoperative and postoperative micro-CT scans were uploaded into image processing software to analyze the changes in the volume of root canal dentin using a mathematical algorithm that enabled progressive differentiation between neighboring pixels after defining and segmenting the root canal systems in both micro-CT scans. Volumetric variations in the root canal system and the root canal third were calculated using a t-test for independent samples or a nonparametric Mann–Whitney–Wilcoxon test. Results: Statistically significant differences (p = 0.0066) in dentin removal capacity were found between the EDG (2.89 ± 1.26 mm3) and RB (1.22 ± 0.58 mm3) study groups for the coronal root canal third; however, no statistically significant differences were found for the middle (p = 0.4864) and apical (p = 0.6276) root canal thirds. Conclusions: Endogal and Reciproc Blue NiTi endodontic reciprocating systems showed similar capacity for the removal of root canal dentin, except for the coronal root canal third, in which the Reciproc Blue NiTi endodontic reciprocating system preserved more root canal dentin tissue.


2021 ◽  
Vol 20 ◽  
pp. e213781
Author(s):  
Monique Marchiori ◽  
Arissa Michelle Yamada Corrêa ◽  
Flávia Sens Fagundes Tomazinho ◽  
Marilisa Carneiro Leão Gabardo ◽  
Natanael Henrique Ribeiro Mattos ◽  
...  

Aim: To evaluate the apical extrusion of debris in flat-oval canals, using three reciprocating systems at two different working lengths (WL), 0 mm and 1 mm from the apical foramen. Methods: Ninety mandibular incisors were randomly divided into three groups based on the systems: WaveOne Gold #25.07 (WOG), ProDesign R #25.06 (PDR), and X1 Blue #25.06 (X1B). Extruded debris were collected and dried in pre-weighed Eppendorf tubes. Three consecutive weighings were performed for each tube, and the mean was calculated. If the assumptions of normality and homogeneity of variance were not met, the Kruskal-Wallis test was used to analyze the amount of extruded debris between groups with the same WL, and the Mann-Whitney U test was used for comparison within groups for each WL. Results: All groups had extruded debris, with higher median values occurring at 1 mm. No significant difference regarding the amount of debris extrusion was observed at 0 mm (p>0.05) and 1 mm (p>0.05) between groups. However, within the groups, at different WL, there was greater extrusion at 1 mm (p<0.05), with PDR differing significantly from the other systems (p<0.05). Conclusion: The extrusion of debris occurred regardless of the group, with higher values at 1 mm. However, using PDR at 1 mm from the apical foramen showed the highest values of extrusion.


2021 ◽  
Vol 4 (2) ◽  
pp. 8877-8889
Author(s):  
Bruno Carvalho de Sousa ◽  
Paulo Henrique da Cunha Sobrinho ◽  
Domingos Cavalcante da Silva ◽  
Juvencio Santos Nobre ◽  
Francisco Luis da Costa de Morais Netto ◽  
...  

2021 ◽  
Vol 10 (3) ◽  
pp. e1710313028
Author(s):  
Ana Elisa Aguiar Campos ◽  
Adriana de Jesus Soares ◽  
Ana Grasiela da Silva Limoeiro ◽  
Fernanda Tessaro Cintra ◽  
Marcos Frozoni ◽  
...  

This study aimed to evaluate, in vitro, the cutting efficiency and time spent for instrumentation of three different heat-treated reciprocating systems in simulated straight canals. Forty-five acrylic blocks with a straight simulated root canal with 21 millimeters in length were initially weighed (P1). After weighing the blocks were divided into three groups (n = 15) and each group prepared with the following systems:  ProDesign R 25.06 (Bassi/Easy, Belo Horizonte, Brazil), Reciproc Blue25.08 (VDW, Munich, Germany) and Wave one Gold (Dentsply Sirona, Ballaigues, Switzerland). The time spent for the total preparation of each block was recorded. After instrumentation, they were subjected to final weighing (P2). The difference between P1 and P2 determined the amount of material removed (cutting efficiency) by each mechanized system. The statistical analysis was performed by the ANOVA test of each of the variables, for multiple comparisons of means the turkey test was used. As for preparation time, it can be seen that ProDesign R showed a longer preparation time (P <0.5) compared to Reciproc Blue and Wave one Gold. Regarding cutting efficiency, there was no statistical difference between the groups (P> 0.5). In straight simulated canals, the type of reciprocating instrument influences the time for instrumentation; however, it shows similar cutting efficiency.


2021 ◽  
Vol 35 ◽  
Author(s):  
Bárbara Maria BIS ◽  
Yara Teresinha Corrêa SILVA-SOUSA ◽  
Luciana Martins Domingues de MACEDO ◽  
Orestes Pereira OLIVEIRA ◽  
Edson ALFREDO ◽  
...  

2020 ◽  
Vol 14 (4) ◽  
pp. 214-217
Author(s):  
Jamileh Ghoddusi ◽  
Ehsan Arian ◽  
Maryam Golmohammadi ◽  
Maryam Gharechahi ◽  
Siavash Moushekhian

Background. The present in vitro study aimed to compare the effectiveness of the WaveOne and ProTaper Gold systems in removing the Enterococcus faecalis biofilm. Methods. Thirty-eight mandibular premolars were selected. The root canals were assigned to standard control (canals serially enlarged with ProTaper Gold S1-S2-F1-F2, n=15) and experimental (canals enlarged with Primary WaveOne file, n=15) groups. Following the instrumentation procedure, the root canals underwent a sampling procedure, and the colonyforming unit (CFU) counts were determined. The samples were also evaluated under a fluorescent microscope to evaluate viable bacteria. The data were analyzed using independent samples t test and paired samples t test. Results. The results showed that, compared with the ProTaper group, the WaveOne group exhibited the least viable bacteria (P=0.004). Conclusion. It was concluded that comparison with the ProTaper Gold rotary system, the WaveOne reciprocating file is more successful in reducing intratubular viable bacteria counts.