scholarly journals Airflow inside the nasal cavity: visualization using computational fluid dynamics

2010 ◽  
Vol 4 (4) ◽  
pp. 657-661 ◽  
Author(s):  
Mohammed Zubair ◽  
Vizy Nazira Riazuddin ◽  
Mohammed Zulkifly Abdullah ◽  
Rushdan Ismail ◽  
Ibrahim Lutfi Shuaib ◽  
...  

Abstract Background: It is of clinical importance to examine the nasal cavity pre-operatively on surgical treatments. However, there is no simple and easy way to measure airflow in the nasal cavity. Objectives: Visualize the flow features inside the nasal cavity using computational fluid dynamics (CFD) method, and study the effect of different breathing rates on nasal function. Method: A three-dimensional nasal cavity model was reconstructed based on computed tomographic images of a healthy Malaysian adult nose. Navier-Stokes and continuity equations for steady airflow were solved numerically to examine the inspiratory nasal flow. Results: The flow resistance obtained varied from 0.026 to 0.124 Pa.s/mL at flow-rate from 7.5 L/min to 40 L/min. Flow rates by breathing had significant influence on airflow velocity and wall shear-stress in the vestibule and nasal valve region. Conclusion: Airflow simulations based on CFD is most useful for better understanding of flow phenomenon inside the nasal cavity.

2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Hassam Nasarullah Chaudhry ◽  
John Kaiser Calautit ◽  
Ben Richard Hughes

The effect of wind distribution on the architectural domain of the Bahrain Trade Centre was numerically analysed using computational fluid dynamics (CFD). Using the numerical data, the power generation potential of the building-integrated wind turbines was determined in response to the prevailing wind direction. The three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations along with the momentum and continuity equations were solved for obtaining the velocity and pressure field. Simulating a reference wind speed of 6 m/s, the findings from the study quantified an estimate power generation of 6.4 kW indicating a capacity factor of 2.9% for the benchmark model. At the windward side of the building, it was observed that the layers of turbulence intensified in inverse proportion to the height of the building with an average value of 0.45 J/kg. The air velocity was found to gradually increase in direct proportion to the elevation with the turbine located at higher altitude receiving maximum exposure to incoming wind. This work highlighted the potential of using advanced computational fluid dynamics in order to factor wind into the design of any architectural environment.


Animals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 2431
Author(s):  
Rocio Fernández-Parra ◽  
Pascaline Pey ◽  
Carol Reinero ◽  
Mauro Malvè

Pressurized metered-dose inhalers (pMDI) with or without spacers are commonly used for the treatment of feline inflammatory airway disease. During traditional airways treatments, a substantial amount of drugs are wasted upstream of their target. To study the efficiency of commonly used devices in the transport of inhaled salbutamol, different computational models based on two healthy adult client-owned cats were developed. Computed tomographic images from one cat were used to generate a three-dimensional geometry, and two masks (spherical and conical shapes) and two spacers (10 and 20 cm) completed the models. A second cat was used to generate a second model having an endotracheal tube (ETT) with and without the same spacers. Airflow, droplet spray transport, and deposition were simulated and studied using computational fluid dynamics techniques. Four regions were evaluated: device, upper airways, primary bronchi, and downstream lower airways/parenchyma (“lung”). Regardless of the model, most salbutamol is deposited in devices and/or upper airways. In general, particles reaching the lung varied between 5.8 and 25.8%. Compared with the first model, pMDI application through the ETT with or without a spacer had significantly higher percentages of particles reaching the lung (p = 0.006).


Author(s):  
Francesco Balduzzi ◽  
Alessandro Bianchini ◽  
Giovanni Ferrara ◽  
David Marten ◽  
George Pechlivanoglou ◽  
...  

Due to the rapid progress in high-performance computing and the availability of increasingly large computational resources, Navier-Stokes computational fluid dynamics (CFD) now offers a cost-effective, versatile and accurate means to improve the understanding of the unsteady aerodynamics of Darrieus wind turbines and deliver more efficient designs. In particular, the possibility of determining a fully resolved flow field past the blades by means of CFD offers the opportunity to both further understand the physics underlying the turbine fluid dynamics and to use this knowledge to validate lower-order models, which can have a wider diffusion in the wind energy sector, particularly for industrial use, in the light of their lower computational burden. In this context, highly spatially and temporally refined time-dependent three-dimensional Navier-Stokes simulations were carried out using more than 16,000 processor cores per simulation on an IBM BG/Q cluster in order to investigate thoroughly the three-dimensional unsteady aerodynamics of a single blade in Darrieus-like motion. Particular attention was payed to tip losses, dynamic stall, and blade/wake interaction. CFD results are compared with those obtained with an open-source code based on the Lifting Line Free Vortex Wake Model (LLFVW). At present, this approach is the most refined method among the “lower-fidelity” models and, as the wake is explicitly resolved in contrast to BEM-based methods, LLFVW analyses provide three-dimensional flow solutions. Extended comparisons between the two approaches are presented and a critical analysis is carried out to identify the benefits and drawbacks of the two approaches.


Author(s):  
Francesco Balduzzi ◽  
David Marten ◽  
Alessandro Bianchini ◽  
Jernej Drofelnik ◽  
Lorenzo Ferrari ◽  
...  

Due to the rapid progress in high-performance computing and the availability of increasingly large computational resources, Navier–Stokes (NS) computational fluid dynamics (CFD) now offers a cost-effective, versatile, and accurate means to improve the understanding of the unsteady aerodynamics of Darrieus wind turbines and deliver more efficient designs. In particular, the possibility of determining a fully resolved flow field past the blades by means of CFD offers the opportunity to both further understand the physics underlying the turbine fluid dynamics and to use this knowledge to validate lower-order models, which can have a wider diffusion in the wind energy sector, particularly for industrial use, in the light of their lower computational burden. In this context, highly spatially and temporally refined time-dependent three-dimensional (3D) NS simulations were carried out using more than 16,000 processor cores per simulation on an IBM BG/Q cluster in order to investigate thoroughly the 3D unsteady aerodynamics of a single blade in Darrieus-like motion. Particular attention was paid to tip losses, dynamic stall, and blade/wake interaction. CFD results are compared with those obtained with an open-source code based on the lifting line free vortex wake model (LLFVW). At present, this approach is the most refined method among the “lower-fidelity” models, and as the wake is explicitly resolved in contrast to blade element momentum (BEM)-based methods, LLFVW analyses provide 3D flow solutions. Extended comparisons between the two approaches are presented and a critical analysis is carried out to identify the benefits and drawbacks of the two approaches.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3350 ◽  
Author(s):  
Guoping Huang ◽  
Xin Xiang ◽  
Chen Xia ◽  
Weiyu Lu ◽  
Lei Li

The reduction in specific fuel consumption (SFC) is crucial for small/mid-size cost-controllable aircraft, which is very conducive to reducing cost and carbon dioxide emissions. To decrease the SFC, increasing the bypass ratio (BPR) is an important way. Conventional high-BPR engines have several limitations, especially the conflicting spool-speed requirements of a fan and a low-pressure turbine. This research proposes an air-driven fan with a tip turbine (ADFTT) as a potential device for a high-bypass propulsion system. Moreover, a possible application of this ADFTT is introduced. Thermodynamic analysis results show that an ADFTT can improve thrust from a prototype turbofan. As a demonstration, we selected a typical small-thrust turbofan as the prototype and applied the ADFTT concept to improve this model. Three-dimensional flow fields were numerically simulated through a Reynolds averaged Navier-Stokes (RANS)-based computational fluid dynamics (CFD) method. The performance of this ADFTT has the possibility of amplifying the BPR more than four times and increasing the thrust by approximately 84% in comparison with the prototype turbofan.


Author(s):  
J. Johansen ◽  
N. N. So̸rensen ◽  
J. A. Michelsen ◽  
S. Schreck

The Detached-Eddy Simulation model implemented in the computational fluid dynamics code, EllipSys3D, is applied on the flow around the NREL Phase-VI wind turbine blade. Results are presented for flow around a parked blade at fixed angle of attack and a blade pitching along the blade axis. Computed blade characteristics are compared with experimental data from the NREL/NASA Ames Phase-VI unsteady experiment. The Detached-Eddy Simulation model is a method for predicting turbulence in computational fluid dynamics computations, which combines a Reynolds Averaged Navier-Stokes method in the boundary layer with a Large Eddy Simulation in the free shear flow. The present study focuses on static and dynamic stall regions highly relevant for stall regulated wind turbines. Computations do predict force coefficients and pressure distributions fairly good and results using Detached-Eddy Simulation show considerably more three-dimensional flow structures compared to conventional two-equation Reynolds Averaged Navier-Stokes turbulence models, but no particular improvements are seen on the global blade characteristics.


1997 ◽  
Vol 119 (1) ◽  
pp. 103-109 ◽  
Author(s):  
B. Newling ◽  
S. J. Gibbs ◽  
J. A. Derbyshire ◽  
D. Xing ◽  
L. D. Hall ◽  
...  

The flow of Newtonian liquids through a pipe system comprising of a series of abrupt expansions and contractions has been studied using several magnetic resonance imaging (MRI) techniques, and also by computational fluid dynamics. Agreement between those results validates the assumptions inherent to the computational calculation and gives confidence to extend the work to more complex geometries and more complex fluids, wherein the advantages of MRI (utility in opaque fluids and noninvasiveness) are unique. The fluid in the expansion-contraction system exhibits a broad distribution of velocities and, therefore, presents peculiar challenges to the measurement technique. The MRI protocols employed were a two-dimensional tagging technique, for rapid flow field visualisation, and three-dimensional echo-planar and gradient-echo techniques, for flow field quantification (velocimetry). The Computational work was performed using the FIDAP package to solve the Navier-Stokes equations. The particular choice of parameters for both MRI and computational fluid dynamics, which affect the results and their agreement, have been addressed.


2018 ◽  
Vol 15 (2) ◽  
pp. 161 ◽  
Author(s):  
Arifin Rasyadi Soemaryanto ◽  
Nurhayyan Halim Rosid

Prediction of an aerodynamic load acting on a wing or usually called wing loading becomes an important stage for structural analysis. Several methods have been used in estimating the wing loading. Schrenk approximation method is commonly used to achieve the fast estimation of lift distribution along wingspan, but in order to achieve a high level accuracy of aerodynamic prediction, computational fluid dynamics (CFD) with Navier Stokes-based equation can be used. LAPAN Surveillance UAV (LSU series) has been chosen to represent an aerodynamics analysis on generic small unmanned aircraft with twinboom vertical stabilizer configuration. This study was focused to verify the Schrenk approximation method using high accuracy numerical simulation (CFD). The goal of this study was to determine the lift distribution along wingspan and a number of errors between Schrenk approximation and CFD method. In this study, Schrenk approximation result showed similarity with the CFX simulation. So the two results have been verified in analysis of wing loading. ABSTRAKPrediksi dari beban aerodinamika yang terjadi pada sayap menjadi salah satu tahap yang penting dalam analisis struktur perancangan pesawat. Beberapa metode telah digunakan untuk mengestimasi besarnya beban aerodinamika pada sayap. Metode Schrenk umum digunakan untuk estimasi cepat perhitungan besar distribusi gaya angkat di sepanjang sayap. Guna mencapai tingkat akurasi yang tinggi dari prediksi aerodinamika, simulasi Computational Fluid Dynamics (CFD) dengan berbasis persamaan Navier-Stokes dapat digunakan. Pesawat nirawak LSU dipilih untuk merepresentasikan analisis aerodinamika pada pesawat nirawak dengan konfigurasi twin-tailboom pusher. Fokus dari studi yang dilakukan adalah untuk memverifikasi dari metode pendekatan dari Schrenk dengan menggunakan metode yang memiliki akurasi tinggi seperti simulasi CFD. Tujuan dari studi adalah untuk menghitung distribusi gaya angkat sepanjang sayap dan menentukan seberapa besar error dari kedua metode.


2017 ◽  
Vol 28 (2) ◽  
pp. 217-234 ◽  
Author(s):  
Y. W. Dai ◽  
C. M. Mak ◽  
Z. T. Ai

Previous studies on inter-unit dispersion around multi-storey buildings focused mostly on an isolated building. Considering that the presence of an upstream building(s) would significantly modify the airflow pattern around a downstream building, this study intends to investigate the influence of such changed airflow patterns on inter-unit dispersion characteristics around a multi-storey building due to wind effect. Computational fluid dynamics (CFD) method in the framework of Reynolds-averaged Navier-stokes modelling was employed to predict the coupled outdoor and indoor airflow field, and the tracer gas technique was used to simulate the dispersion of infectious agents between units. Based on the predicted concentration field, a mass conservation based parameter, namely re-entry ratio, was used to evaluate quantitatively the inter-unit dispersion possibilities and thus assess risks along different routes. The presence of upstream building(s) could disrupt the strong impingement of approaching flows but brings a more complex and irregular airflow pattern around the downstream multi-storey buildings, leading to a more scattered distribution of re-entry ratio values among different units and uncertain dispersion routes. Generally, the tracer gas concentration in most units was lower than those in an isolated building, although very high concentrations were found in some specific areas.


Sign in / Sign up

Export Citation Format

Share Document