MRI studies in parotid tumors: Differentiation between benign and malignant lesions. What the radiology trainee should know

Author(s):  
Soung Yung Kim ◽  
Martin H. Maurer ◽  
Dr Christophe Schroeder ◽  
Meinrad Beer
2007 ◽  
Vol 14 (6) ◽  
pp. 701-710 ◽  
Author(s):  
Sedat Alibek ◽  
Johannes Zenk ◽  
Alessandro Bozzato ◽  
Michael Lell ◽  
Markus Grunewald ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Francesca Piludu ◽  
Simona Marzi ◽  
Marco Ravanelli ◽  
Raul Pellini ◽  
Renato Covello ◽  
...  

BackgroundThe differentiation between benign and malignant parotid lesions is crucial to defining the treatment plan, which highly depends on the tumor histology. We aimed to evaluate the role of MRI-based radiomics using both T2-weighted (T2-w) images and Apparent Diffusion Coefficient (ADC) maps in the differentiation of parotid lesions, in order to develop predictive models with an external validation cohort.Materials and MethodsA sample of 69 untreated parotid lesions was evaluated retrospectively, including 37 benign (of which 13 were Warthin’s tumors) and 32 malignant tumors. The patient population was divided into three groups: benign lesions (24 cases), Warthin’s lesions (13 cases), and malignant lesions (32 cases), which were compared in pairs. First- and second-order features were derived for each lesion. Margins and contrast enhancement patterns (CE) were qualitatively assessed. The model with the final feature set was achieved using the support vector machine binary classification algorithm.ResultsModels for discriminating between Warthin’s and malignant tumors, benign and Warthin’s tumors and benign and malignant tumors had an accuracy of 86.7%, 91.9% and 80.4%, respectively. After the feature selection process, four parameters for each model were used, including histogram-based features from ADC and T2-w images, shape-based features and types of margins and/or CE. Comparable accuracies were obtained after validation with the external cohort.ConclusionsRadiomic analysis of ADC, T2-w images, and qualitative scores evaluating margins and CE allowed us to obtain good to excellent diagnostic accuracies in differentiating parotid lesions, which were confirmed with an external validation cohort.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Jan Heřman ◽  
Zuzana Sedláčková ◽  
Jaromír Vachutka ◽  
Tomáš Fürst ◽  
Richard Salzman ◽  
...  

Aim. To create a predictive score for the discrimination between benign and malignant parotid tumors using elastographic parameters and to compare its sensitivity and specificity with standard ultrasound. Methods. A total of 124 patients with parotid gland lesions for whom surgery was planned were examined using conventional ultrasound, Doppler examination, and shear wave elastography. Results of the examinations were compared with those ones of histology. Results. There were 96 benign and 28 malignant lesions in our cohort. Blurred tumor margin alone proved to be an excellent predictor of malignancy with the sensitivity of 79% and specificity of 97%. Enlarged cervical lymph nodes, tumor vascularisation, microcalcifications presence, homogeneous echogenicity, and bilateral occurrence also discriminated between benign and malignant tumors. However, their inclusion in a predictive model did not improve its performance. Elastographic parameters (the stiffness maxima and minima ratio being the best) also exhibited significant differences between benign and malignant tumors, but again, their inclusion did not significantly improve the predictive power of the blurred margin classifier. Conclusion. Even though elastography satisfactorily distinguishes benign from malignant lesions on its own, it hardly provides any additional value in evaluation of biological character of parotid gland tumors when used as an adjunct to regular ultrasound examination.


1953 ◽  
Vol 25 (2) ◽  
pp. 202-217 ◽  
Author(s):  
James A. Dolphin ◽  
Lucian A. Smith ◽  
John M. Waugh

2002 ◽  
Author(s):  
Ellert R. S. Nijenhuis ◽  
Thomas Ehling ◽  
Allard Krikke

2002 ◽  
Vol 41 (05) ◽  
pp. 208-213 ◽  
Author(s):  
L. M. Haslinghuis-Bajan ◽  
L. Hooft ◽  
A. van Lingen ◽  
M. van Tulder ◽  
W. Devillé ◽  
...  

SummaryAim: While FDG full ring PET (FRPET) has been gradually accepted in oncology, the role of the cheaper gamma camera based alternatives (GCPET) is less clear. Since technology is evolving rapidly, “tracker trials” would be most helpful to provide a first approximation of the relative merits of these alternatives. As difference in scanner sensitivity is the key variable, head-to-head comparison with FRPET is an attractive study design. This systematic review summarises such studies. Methods: Nine studies were identified until July 1, 2000. Two observers assessed the methodological quality (Cochrane criteria), and extracted data. Results: The studies comprised a variety of tumours and indications. The reported GC- and FRPET agreement for detection of malignant lesions ranged from 55 to 100%, but with methodological limitations (blinding, standardisation, limited patient spectrum). Mean lesion diameter was 2.9 cm (SD 1.8), with only about 20% <1.5 cm. The 3 studies with the highest quality reported concordances of 74-79%, for the studied lesion spectrum. Contrast at GCPET was lower than that of FRPET, contrast and detection agreement were positively related. Logistic regression analysis suggested that pre-test indicators might be used to predict FRPET-GCPET concordance. Conclusion: In spite of methodological limitations, “first generation” GCPET devices detected sufficient FRPET positive lesions to allow prospective evaluation in clinical situations where the impact of FRPET is not confined to detection of small lesions (<1.5 cm). The efficiency of head-to-head comparative studies would benefit from application in a clinically relevant patient spectrum, with proper blinding and standardisation of acquisition procedures.


1997 ◽  
Vol 36 (08) ◽  
pp. 282-288 ◽  
Author(s):  
T. Atasever ◽  
A. Özdemir ◽  
I. Öznur ◽  
N. I. Karabacak ◽  
N. Gökçora ◽  
...  

Summary Aim: Our goal was to determine the clinical usefulness of TI-201 to identify breast cancer in patients with suspicious breast lesions on clinical examination, and/or abnormal radiologic (mammography and/or ultrasonography) findings. Methods: TI-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of TI-201. Visual and semiquantitative interpretation was performed. Results: Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. TI-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by TI-201 scintigraphy. The smallest mass lesion detected by TI-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. TI-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed TI-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated TI-201. TI-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by TI-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58 ± 0.38 (mean ± SD) and 1.48 ± 0.32 (p >0.05), 1.87 ± 0.65 and 1.34 ± 0.20 (p<0.05) respectively. The mean early and late L/N ratios of malignant and benign groups did not show statistical difference (p>0.05). Conclusion: Overall, TI-201 scintigraphy was the most specific of the three methods and yielded favourable results in palpable breast cancers, while it showed lower sensitivity in nonpalpable cancers and axillary metastases. Combined use of TI-201 scintigraphy with mammography and US seems to be useful in difficult cases, such as dense breasts and indeterminate breast lesions.


Author(s):  
Suraj Mathur

This prospective study was done in the Department of Radio diagnosis Govt. Medical College, Kozhikode. A total of 65 patients who were referred to our department with clinical suspicion of endometrial lesions and incidentally detected endometrial lesions on ultrasonography underwent transvaginal ultrasound and subsequent Imaging evaluation of pelvis MRI has very high sensitivity (95%) and specificity (98%) and is almost as accurate (97%) as histopathology in differentiating benign from malignant lesions. Addition of DWI with ADC mapping to conventional MRI increases its accuracy even more. However there is inherent limitation to MRI in detecting carcinoma in situ and micrometastasis. Keywords: TVS, MRI, Sensitivity, Specificity, Histopathology.


Author(s):  
Bhawana Pant ◽  
Sanjay Gaur ◽  
Prabhat Pant

F.NA.C has been used for ages as a safe and economical tool for fast preoperative diagnosis of parotid tumors. It has certain pitfall which sometimes leads to misdiagnosis and consequently it may have affect on treatment of the tumors. Keeping in view of the diverse classification of parotid tumors’ information from cytology should be combined with radiology as well as clinical diagnosis. Aim: To discuss some cases where there was discrepancy between cytological diagnosis and histopathological result and also suggest measures to improve the efficacy of F.N.A.C. Material and methods: The study includes 50 cases of parotid tumours who presented to the  department of ENT at Government medical college Haldwani which is a tertiary referral centre during 2009 to 2016. Only adult patients were included and inflammatory swelling were excluded from the study. All patients evaluated  Contrast enhanced computerized tomography(CECT) and  Magnetic resonance imaging (MRI) followed by Fine needle aspiration cytology .Preoperative diagnosis was made upon the findings of the above investigations and different types of  parotid surgeries  were done. . Final diagnosis was made on  histopathological  examination. Result :The most common tumour  came out to be pleomorphic adenoma (23 cases-46%) followed by mucoepidermoid carcinoma(12cases-24%). In ten  cases there was no clear cut  association between cytological diagnosis and final histopathological diagnosis. Conclusion: FNAC is highly sensitive and specific technique for diagnosis of many salivary gland swellings. FNAC can be used preoperatively to avoid unnecessary surgery and biopsy. Details of clinical information and radiologic features may help the pathologist to arrive at the appropriate diagnosis and reduce false interpretation. Pitfalls may also occur with improper technique of FNAC which can be overcome by proper caution.


Sign in / Sign up

Export Citation Format

Share Document