scholarly journals Surface Area

2021 ◽  
Vol 15 (3) ◽  
pp. 538-542
Author(s):  
Terry Trowbridge
Keyword(s):  
Author(s):  
A. Legrouri

The industrial importance of metal catalysts supported on reducible oxides has stimulated considerable interest during the last few years. This presentation reports on the study of the physicochemical properties of metallic rhodium supported on vanadium pentoxide (Rh/V2O5). Electron optical methods, in conjunction with other techniques, were used to characterise the catalyst before its use in the hydrogenolysis of butane; a reaction for which Rh metal is known to be among the most active catalysts.V2O5 powder was prepared by thermal decomposition of high purity ammonium metavanadate in air at 400 °C for 2 hours. Previous studies of the microstructure of this compound, by HREM, SEM and gas adsorption, showed it to be non— porous with a very low surface area of 6m2/g3. The metal loading of the catalyst used was lwt%Rh on V2Q5. It was prepared by wet impregnating the support with an aqueous solution of RhCI3.3H2O.


Author(s):  
M. Marko ◽  
A. Leith ◽  
D. Parsons

The use of serial sections and computer-based 3-D reconstruction techniques affords an opportunity not only to visualize the shape and distribution of the structures being studied, but also to determine their volumes and surface areas. Up until now, this has been done using serial ultrathin sections.The serial-section approach differs from the stereo logical methods of Weibel in that it is based on the Information from a set of single, complete cells (or organelles) rather than on a random 2-dimensional sampling of a population of cells. Because of this, it can more easily provide absolute values of volume and surface area, especially for highly-complex structures. It also allows study of individual variation among the cells, and study of structures which occur only infrequently.We have developed a system for 3-D reconstruction of objects from stereo-pair electron micrographs of thick specimens.


1996 ◽  
Vol 76 (05) ◽  
pp. 682-688 ◽  
Author(s):  
Jos P J Wester ◽  
Harold W de Valk ◽  
Karel H Nieuwenhuis ◽  
Catherine B Brouwer ◽  
Yolanda van der Graaf ◽  
...  

Summary Objective: Identification of risk factors for bleeding and prospective evaluation of two bleeding risk scores in the treatment of acute venous thromboembolism. Design: Secondary analysis of a prospective, randomized, assessor-blind, multicenter clinical trial. Setting: One university and 2 regional teaching hospitals. Patients: 188 patients treated with heparin or danaparoid for acute venous thromboembolism. Measurements: The presenting clinical features, the doses of the drugs, and the anticoagulant responses were analyzed using univariate and multivariate logistic regression analysis in order to evaluate prognostic factors for bleeding. In addition, the recently developed Utrecht bleeding risk score and Landefeld bleeding risk index were evaluated prospectively. Results: Major bleeding occurred in 4 patients (2.1%) and minor bleeding in 101 patients (53.7%). For all (major and minor combined) bleeding, body surface area ≤2 m2 (odds ratio 2.3, 95% Cl 1.2-4.4; p = 0.01), and malignancy (odds ratio 2.4, 95% Cl 1.1-4.9; p = 0.02) were confirmed to be independent risk factors. An increased treatment-related risk of bleeding was observed in patients treated with high doses of heparin, independent of the concomitant activated partial thromboplastin time ratios. Both bleeding risk scores had low diagnostic value for bleeding in this sample of mainly minor bleeders. Conclusions: A small body surface area and malignancy were associated with a higher frequency of bleeding. The bleeding risk scores merely offer the clinician a general estimation of the risk of bleeding. In patients with a small body surface area or in patients with malignancy, it may be of interest to study whether limited dose reduction of the anticoagulant drug may cause less bleeding without affecting efficacy.


Author(s):  
Mehmet Emin Simsek ◽  
Mustafa Akkaya ◽  
Safa Gursoy ◽  
Özgür Kaya ◽  
Murat Bozkurt

AbstractThis study aimed to investigate whether overhang or underhang around the tibial component that occurs during the placement of tibial baseplates was affected by different slope angles of the tibial plateau and determine the changes in the lateral and medial plateau diameters while changing the slope angle in total knee arthroplasty. Three-dimensional tibia models were reconstructed using the computed tomography scans of 120 tibial dry bones. Tibial plateau slope cuts were performed with 9, 7, 5, 3, and 0 degrees of slope angles 2-mm below the subchondral bone in the deepest point of the medial plateau. Total, lateral, and medial tibial plateau areas and overhang/underhang rates were measured at each cut level. Digital implantations of the asymmetric and symmetric tibial baseplates were made on the tibial plateau with each slope angles. Following the implantations, the slope angle that prevents overhang or underhang at the bone border and the slope angle that has more surface area was identified. A significant increase was noted in the total tibial surface area, lateral plateau surface area, and lateral anteroposterior distance, whereas the slope cut angles were changed from 9 to 0 degrees in both gender groups. It was found that the amount of posteromedial underhang and posterolateral overhang increased in both the asymmetric and symmetric tibial baseplates when the slope angle was changed from 0 to 9 degrees. Although the mediolateral diameter did not change after the proximal tibia cuts at different slope angles, the surface area and anteroposterior diameter of the lateral plateau could change, leading to increased lateral plateau area. Although prosthesis designs are highly compatible with the tibial surface area, it should be noted that the component overhangs, especially beyond the posterolateral edge, it can be prevented by changing the slope cut angle in males and females.


2020 ◽  
pp. 32-41
Author(s):  
V. P. Zudin

The article presents new, more accurate algorithms and formulas for calculating the area of a circle, volume of a ball, surface area of a ball. To prove these algorithms and formulas and their practical application, programs have been developed in the Visual Basic for Application in Microsoft Word. These algorithms and formulas should be studied and applied in all educational institutions, as they are closer to the truth. From a more accurate calculation using these formulas, you can get an economic effect when calculating trajectories of movements in space, on the surface of the globe, in the construction and maintenance of products in the form of a circle or a ball. The study of this material in informatics lessons contributes to the development of students' creative thinking, increasing their motivation to study informatics and IT.


Author(s):  
Shirazu I. ◽  
Theophilus. A. Sackey ◽  
Elvis K. Tiburu ◽  
Mensah Y. B. ◽  
Forson A.

The relationship between body height and body weight has been described by using various terms. Notable among them is the body mass index, body surface area, body shape index and body surface index. In clinical setting the first descriptive parameter is the BMI scale, which provides information about whether an individual body weight is proportionate to the body height. Since the development of BMI, two other body parameters have been developed in an attempt to determine the relationship between body height and weight. These are the body surface area (BSA) and body surface index (BSI). Generally, these body parameters are described as clinical health indicators that described how healthy an individual body response to the other internal organs. The aim of the study is to discuss the use of BSI as a better clinical health indicator for preclinical assessment of body-organ/tissue relationship. Hence organ health condition as against other body composition. In addition the study is `also to determine the best body parameter the best predict other parameters for clinical application. The model parameters are presented as; modeled height and weight; modelled BSI and BSA, BSI and BMI and modeled BSA and BMI. The models are presented as clinical application software for comfortable working process and designed as GUI and CAD for use in clinical application.


2004 ◽  
Author(s):  
A. Maynard ◽  
B. Ku ◽  
P. Andresen ◽  
G. Ramachandran ◽  
P. Pai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document