scholarly journals Effect of Adhesion Booster on Fluoride-releasing Composite: An in vitro Study

2018 ◽  
Vol 7 (2) ◽  
pp. 28-31
Author(s):  
Varunjeet Chaudhary ◽  
Sanad Singh Solanki ◽  
Varsha Yadav ◽  
Seema Lahoti

Objective: To evaluate the shear bond strength of stainless steel brackets bonded with fluoride-releasing composite resins, comparing effect of adhesion booster and conventional primer.Materials & Method: Sixty extracted premolars were subjected to bracket bonding with fluoride-releasing composite resin; which were bonded by randomly divided into two groups of bonding agents: Group 1- conventional primer as control group, Group 2- adhesion booster. After bonding, the samples were thermocycled (500 cycles) at 5ºC and 55ºC temperatures. After 48 hours they were subjected to shear bond strength testing in occluso-gingival direction, using an MTS 810 Universal Testing Machine with load speed of 0.5 mm/min.Result: Mean shear bond strength was significantly more in samples bonded with adhesion booster (14.792±3.805 Mpa) as compared to conventional primers (11.327±4.047 Mpa). There was statistically significant difference in shear bond strength between the groups (p=0.001).Conclusion: The use of the adhesion booster significantly increased the bond strength of bracket bonded with fluoride-releasing composite.

2020 ◽  
Vol 23 (1) ◽  
Author(s):  
Menna Ahmed ElGendy ◽  
Ihab Mosleh ◽  
Hanaa Zaghloul

Objective: the purpose of the study was to evaluate the micro-shear bond strength of different cements to translucent zirconia before and after thermocycling aging. Material and methods: Twelve translucent zirconia ceramic discs were used in the study. Specimens were sandblasted using 50 ‎μm aluminum oxide (Al2O3) particles. The specimens were divided into three groups (n = 4) according to the cement type: Panavia resin cement (control group), resin modified glass ionomer (RMGI), and Activa bioactive cement. Each group was further sub-divided into two equal subgroups (n = 2) according to whether the specimens were subjected to thermocycling or not. Thermocycling was performed in distilled water at 5000 cycles between 5 oC - 55 oC. The micro-shear bond strength test (μSBS) was measured using universal testing machine. Kruskal-Wallis test was used to compare between the three cements. Dunn’s test was used for pair-wise comparisons when Kruskal-Wallis test is significant. Mann-Whitney U test was used to compare between micro-shear bond strength before and after thermocycling P ≤ 0.05. Results: In non-aged subgroups, there was no significant difference between Panavia and Activa; both showed significantly the highest mean μSBS values (22.9 MPa, 31.3 MPa respectively). While, RMGI showed the lowest μSBS values (4.7 MPa).  In thermocycled subgroups, Panavia showed significantly the highest mean μSBS values (32.2 MPa). There was no significant difference between RMGI and Activa; both showed the lowest significant mean μSBS values (3.2 MPa and 8.7 MPa respectively). Conclusions: RMGI and Activa couldn’t be considered long-term reliable materials for cementing zirconia. However, Panavia provided the most durable bond to zirconia.KEYWORDSBioactive cement; Micro-shear bond strength; Resin cement; Translucent zirconia.


2020 ◽  
Vol 8 (10) ◽  
pp. 454-459
Author(s):  
Bhalla V. ◽  
◽  
K. Goud M. ◽  
Chockattu S. ◽  
Khera A ◽  
...  

Background:Dentin bonding is an ever-evolving field in adhesive dentistry. With the introduction of newer systems into the market, there is a crucial need to test their efficiency in terms of bond strength. Dual-cured adhesives in theory may provide for a better degree of conversion as compared to conventional light-cured adhesives .Thus, the aim of this study was to compare the shear bond strength of three different self-etch adhesives namely ClearfilSE bond (Kuraray), Tetric N Bond Universal (IvoclarVivadent) and Futura Bond DC (Voco) to dentin. Materials & Methods: Ninety extracted non-carious, intact human mandibular molar teeth were selected for this study. Each tooth was decoronated using a double-sided diamond disc with water coolant to a depth of 2mm from the cusp tip .The cut dentin surface was then abraded against 600-grit wet silicon carbide papers for 60 seconds to produce a uniform smear layer. The root portion of each tooth was mounted on a plastic ring using cold cure acrylic resin. Specimens were then divided into three adhesive groups of 30 teeth each, Group A: ClearfilSE Bond (Kuraray), Group B: Tetric N Bond Universal (IvoclarVivadent), Group C :Futura Bond DC (Voco). All bonding agents were used according to the manufacturers’ instructions, in combination with the resin composite Tetric N Ceram (IvoclarVivadent). The samples were thermocycled, followed by shear bond strength testing using a Universal testing machine (Hounsfield). Data were subjected to statistical analysis using one-way analysis of variance (ANOVA) (P<0.05) and Post hoc Tukey’s test for inter- and intra- group analysis respectively. Results: Clearfil SE Bond yielded the highest shear bond strength values (30.9 ±4.66 MPa) which were statistically significant, followed byTetric N Bond Universal group (29.8 ±4.34) and the lowest shear bond strength values were recorded for Futura Bond DC (18.2 ±3.13). Conclusion: Clearfil SE bond and Tetric N bond Universal can be considered as better options than Futura Bond DC.


2016 ◽  
Vol 17 (12) ◽  
pp. 997-1002 ◽  
Author(s):  
Fahad I Alkhudhairy ◽  
Zeeshan H Ahmad

ABSTRACT Introduction Various bulk-fill materials depending on their composition, viscosity, and flow ability have different physical and mechanical properties. The aim of this in vitro study was to determine and compare the shear bond strength and microleakage properties of activa restorative with other bulk-fill restorative materials surefil (SDR), Biodentine, ever X posterior. Materials and methods Forty permanent premolars were selected for shear bond strength, and 20 permanent premolars were selected with class II cavities on mesial and distal side for microleakage. Universal testing device was used to assess the shear bond strength. Microleakage was checked using dye penetration method under a stereomicroscope. Mean and standard deviation values were calculated from the recorded values. Intergroup comparison was done by one-way analysis of variance (ANOVA) followed by pairwise comparison using Tukey honestly significant difference (HSD) post hoc test. Results The mean shear bond strength was highest for SDR surefil followed by Ever X posterior, Bioactive restorative, and Biodentine respectively. In this study, SDR (surefil) showed better shear bond strength and better microleakage properties compared with the other test materials (F = 186.7157, p < 0.05). Conclusion The result of this study showed that flowable and fiber-reinforced composites have better shear bond strength and microleakage properties. Clinical significance Flowable bulk-fill composite resins can be used as dentin substitutes because of its superior properties. How to cite this article Alkhudhairy FI, Ahmad ZH. Comparison of Shear Bond Strength and Microleakage of Various Bulk-fill Bioactive Dentin substitutes: An in vitro study. J Contemp Dent Pract 2016;17(12):997-1002.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Andreas Hellak ◽  
Jennifer Ebeling ◽  
Michael Schauseil ◽  
Steffen Stein ◽  
Matthias Roggendorf ◽  
...  

Objective.The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™.Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces,n=30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05).Results. Significant differences in SBS and ARI were found between the control group and experimental groups.Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


2015 ◽  
Vol 5 (2) ◽  
pp. 65-68
Author(s):  
Shruti Patil ◽  
Prajna Shetty

ABSTRACT Background The dentin desensitizers available for in-office application for prevention and/or treatment of post restorative dentinal hypersensitivity, act by blocking the open dentinal tubules. In doing so, they may influence the bond strength of the restorative resins. Thus, the aim of the study was to evaluate the effect of desensitizers on the shear bond strength of dentin adhesives and to check the extent of dentinal tubule occlusion caused by these desensitizers. Materials and Methods Sixty-four premolars were randomly divided into four groups of sixteen each. The middle depth dentin was exposed by on the buccal surface and was etched using 37% phosphoric acid and rinsed. They were assigned to, Group 1: Gluma desensitizer, Group 2: Vivasens desensitizer, Group 3: Gluma Comfort Bond and desensitizer, and Group 4: Adper Single Bond 2. Composite resin post of 2 mm in height and width were built on these specimens. The samples were then mounted in acrylic resin blocks. Universal testing machine was used to test the shear bond strength. The data were analyzed using one-way analysis of variance (ANOVA) and post hoc Tukey's test. Results The mean values of the shear bond strength were for: Group 1—18.61 ± 1.03 MPa, Group 2—17.53 ± 1.36 MPa, Group 3—22.63 ± 1.61 MPa and Group 4—23.12 ± 1.02 MPa. There was a statistically significant difference (p < 0.05) among the groups. Conclusion The use of dentin desensitizers’ influences bond strength between the tooth and the adhesive. Among the various agents, the single bottle system containing Gluma comfort bond and desensitizer had the best adhesion among the desensitizer groups. How to cite this article Patil S, Naik B, Shetty P. A Comparative Evaluation of Three Commercially Available Dentin Desensitizers on the Shear Bond Strength of Composite Resins: An in vitro Study. J Contemp Dent 2015;5(2):65-68.


2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Homa Farhadifard ◽  
Loghman Rezaei-Soufi ◽  
Maryam Farhadian ◽  
Parisa Shokouhi

Abstract Background At present, the demand for orthodontic treatment is on the rise. On the other hand, evidence shows that the bond strength of composite resins to old composite restorations is often unreliable. Therefore, the aim of this in vitro study was to assess the effect of different surface treatments on shear bond strength (SBS) of ceramic brackets to old composite restorations. Methods In this in vitro experimental study, 60 nano-hybrid composite discs were fabricated. For aging, the discs were incubated in deionized water at 37 °C for 1 month. Next, they underwent 4 different surface treatments namely acid etching with 37% phosphoric acid, sandblasting, grinding, and Er,Cr:YSGG laser irradiation. Ceramic brackets were then bonded to the discs and underwent SBS testing. Results The maximum mean SBS value was obtained in the grinding group (9.16 ± 2.49 MPa), followed by the sandblasting (8.13 ± 2.58 MPa) and laser (6.57 ± 1.45 MPa) groups. The minimum mean SBS value was noted in the control group (5.07 ± 2.14 MPa). Conclusion All groups except for the control group showed clinically acceptable SBS. Therefore, grinding, sandblasting, and Er,Cr:YSGG laser are suggested as effective surface treatments for bonding of ceramic orthodontic brackets to aged composite.


2021 ◽  
Author(s):  
Ladan Ranjbar Omrani ◽  
Saba Tohidkhah ◽  
Elham Ahmadi ◽  
Mahdi Abbasi ◽  
Reza Morvaridi Farimani

Abstract Background: The aim of the current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.


2014 ◽  
Vol 1025-1026 ◽  
pp. 385-390
Author(s):  
Niwat Anuwongnukroh ◽  
Surachai Dechkunakorn ◽  
Jirawat Arunakol ◽  
Wassana Wichai

One of the problems that often occurred during orthodontic treatment is bracket failure. This is usually the result either of the patient’s accidentally, applying inappropriate forces to the bracket or of a poor bonding technique. Thus, a significant number of teeth have to be rebonded in an orthodontic practice. Objective: The aim of this study was to evaluate the in vitro initial repeated shear bond strength of the three adhesive systems at two and five minutes after placement of a bracket. Materials and Methods: The three bonding agent adhesives are System1+, Rely-a-bond, Unite. Two hundred and forty human premolar teeth were divided into two groups, a control and an experimental group. Each group was further divided into three subgroups for bonding brackets with the three different adhesives. Only the teeth in the experimental group were sequentially bonded and debonded two times with the same adhesive. The teeth in control and experimental groups were tested for shear bond strength (at two and five minutes after the bracket was bonded) with an Instron testing machine. Results: The studies were found that : (1) there were differences between the shear bond strength of each adhesive in the control and experimental group. Unite had the highest shear bond strength followed by Rely-a-bond and System1+ at two minutes and five minutes, (2) the experiment group ( rebonded brackets) had higher shear bond strength than control group and Unite had in significant difference (p<0.05) of initial repeated bond strength with System1+ and Rely-a-bond at two minutes and five minutes and (3) there were mostly significant difference (p<0.05) between repeated shear bond strength at two minutes and repeated shear bond strength at five minutes. Conclusion: There were significant difference of the initial repeated shear bond strength of each adhesive. The orthodontists should be aware of applying force for tooth movement into the repeated bonding brackets.


Author(s):  
Zahra Khamverdi ◽  
Naemeh Karimian ◽  
Maryam Farhadian ◽  
Hamed Gheitouli

Objectives: Bond strength of composite restorations plays an important role in their success. This in vitro study evaluated the effect of a hemostatic agent on shear bond strength of universal adhesives. Materials and Methods: Thirty-six extracted human molars were used in this study. Buccal and lingual surfaces were reduced to obtain flat dentin surfaces and were ground with a silicone paper. The samples were randomly divided into three groups (n=12) based on the application of hemostatic agent: group 1: no contamination (control), group 2: aluminum chloride application, and group 3: ferric sulfate application. Each group was then divided into two subgroups (n=6) for using G-Premio and Single Bond Universal. Resin cylinders (Filtek Z550) were bonded to dentin surfaces according to the manufacturer’s instructions. After 1000 thermal cycles, shear load was applied to the specimens using a universal testing machine at a crosshead speed of 1 mm/min until failure. Data were statistically analyzed using two-way ANOVA and Tukey’s post-hoc test (α=0.05). Results: There were statistically significant differences in shear bond strength of the three main groups for both G-Premio and Single Bond Universal (P<0.05). When the adhesive systems were compared with each other, G-Premio showed higher shear bond strength than Single Bond Universal (P<0.05). Conclusion: Contamination with hemostatic agents had an adverse effect on the shear bond strength of universal adhesives. Moreover, G-Premio yielded a higher bond strength than Single Bond Universal.


Sign in / Sign up

Export Citation Format

Share Document