scholarly journals Orientation of Temporal Interference for Non-invasive Deep Brain Stimulation in Epilepsy

2021 ◽  
Vol 15 ◽  
Author(s):  
Florian Missey ◽  
Evgeniia Rusina ◽  
Emma Acerbo ◽  
Boris Botzanowski ◽  
Agnès Trébuchon ◽  
...  

In patients with focal drug-resistant epilepsy, electrical stimulation from intracranial electrodes is frequently used for the localization of seizure onset zones and related pathological networks. The ability of electrically stimulated tissue to generate beta and gamma range oscillations, called rapid-discharges, is a frequent indication of an epileptogenic zone. However, a limit of intracranial stimulation is the fixed physical location and number of implanted electrodes, leaving numerous clinically and functionally relevant brain regions unexplored. Here, we demonstrate an alternative technique relying exclusively on non-penetrating surface electrodes, namely an orientation-tunable form of temporally interfering (TI) electric fields to target the CA3 of the mouse hippocampus which focally evokes seizure-like events (SLEs) having the characteristic frequencies of rapid-discharges, but without the necessity of the implanted electrodes. The orientation of the topical electrodes with respect to the orientation of the hippocampus is demonstrated to strongly control the threshold for evoking SLEs. Additionally, we demonstrate the use of Pulse-width-modulation of square waves as an alternative to sine waves for TI stimulation. An orientation-dependent analysis of classic implanted electrodes to evoke SLEs in the hippocampus is subsequently utilized to support the results of the minimally invasive temporally interfering fields. The principles of orientation-tunable TI stimulation seen here can be generally applicable in a wide range of other excitable tissues and brain regions, overcoming several limitations of fixed electrodes which penetrate tissue and overcoming several limitations of other non-invasive stimulation methods in epilepsy, such as transcranial magnetic stimulation (TMS).

2020 ◽  
Author(s):  
Florian Missey ◽  
Evgeniia Rusina ◽  
Emma Acerbo ◽  
Boris Botzanowski ◽  
Romain Carron ◽  
...  

AbstractIn patients with focal drug-resistant epilepsy, electrical stimulation from intracranial electrodes is frequently used for the localization of seizure onset zones and related pathological networks. The ability of electrically stimulated tissue to generate beta and gamma range oscillations, called rapid-discharges, is a frequent indication of an epileptogenic zone. However, a limit of intracranial stimulation is the fixed physical location and number of implanted electrodes, leaving numerous clinically and functionally relevant brain regions unexplored. Here, we demonstrate an alternative technique relying exclusively on nonpenetrating surface electrodes, namely an orientation-tunable form of temporally-interfering (TI) electric fields to target the CA3 of the mouse hippocampus which focally evokes seizure-like events (SLEs) having the characteristic frequencies of rapid-discharges, but without the necessity of the implanted electrodes. The orientation of the topical electrodes with respect to the orientation of the hippocampus is demonstrated to strongly control the threshold for evoking SLEs. Additionally, we demonstrate the use of square waves as an alternative to sine waves for TI stimulation. An orientation-dependent analysis of classic implanted electrodes to evoke SLEs in the hippocampus is subsequently utilized to support the results of the minimally-invasive temporally-interfering fields. The principles of orientation-tunable TI stimulation seen here can be generally applicable in a wide range of other excitable tissues and brain regions, overcoming several limitations of fixed electrodes which penetrate tissue.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jill von Conta ◽  
Florian H. Kasten ◽  
Branislava Ćurčić-Blake ◽  
André Aleman ◽  
Axel Thielscher ◽  
...  

AbstractTranscranial temporal interference stimulation (tTIS) is a novel non-invasive brain stimulation technique for electrical stimulation of neurons at depth. Deep brain regions are generally small in size, making precise targeting a necessity. The variability of electric fields across individual subjects resulting from the same tTIS montages is unknown so far and may be of major concern for precise tTIS targeting. Therefore, the aim of the current study is to investigate the variability of the electric fields due to tTIS across 25 subjects. To this end, the electric fields of different electrode montages consisting of two electrode pairs with different center frequencies were simulated in order to target selected regions-of-interest (ROIs) with tTIS. Moreover, we set out to compare the electric fields of tTIS with the electric fields of conventional tACS. The latter were also based on two electrode pairs, which, however, were driven in phase at a common frequency. Our results showed that the electric field strengths inside the ROIs (left hippocampus, left motor area and thalamus) during tTIS are variable on single subject level. In addition, tTIS stimulates more focally as compared to tACS with much weaker co-stimulation of cortical areas close to the stimulation electrodes. Electric fields inside the ROI were, however, comparable for both methods. Overall, our results emphasize the potential benefits of tTIS for the stimulation of deep targets, over conventional tACS. However, they also indicate a need for individualized stimulation montages to leverage the method to its fullest potential.


2019 ◽  
Author(s):  
Sina Farahmand ◽  
Tiwalade Sobayo ◽  
David J. Mogul

AbstractObjectiveFor more than 25 million drug-resistant epilepsy patients, surgical intervention aiming at resecting brain regions where seizures arise is often the only alternative therapy. However, the identification of this epileptogenic zone (EZ) is often imprecise which may affect post-surgical outcomes (PSOs). Interictal high-frequency oscillations (HFOs) have been revealed to be reliable biomarkers in delineating EZ. In this paper, an analytical methodology aiming at automated detection and classification of interictal HFOs is proposed to improve the identification of EZ. Furthermore, the detected high-rate HFO areas were compared with the seizure onset zones (SOZs) and resected areas to investigate their clinical relevance in predicting PSOs.MethodsFIR band-pass filtering as well as a combination of time-series local energy, peak, and duration analysis were utilized to identify high-rate HFO areas in interictal, multi-channel intracranial electroencephalographic (iEEG) recordings. The detected HFOs were then classified into fast-ripple (FR), ripple (R), and fast-ripple concurrent with ripple (FRandR) events.ResultsThe proposed method resulted in sensitivity of 91.08% and false discovery rate of 7.32%. Moreover, it was found that the detected HFO-FRandR areas in concordance with the SOZs would have better delineated the EZ for each patient, while limiting the area of the brain required to be resected.ConclusionTesting on a dataset of 20 patients has supported the feasibility of using this method to provide an automated algorithm to better delineate the EZ.SignificanceThe proposed methodology may significantly improve the precision by which pathological brain tissue can be identified.


Neurosurgery ◽  
2015 ◽  
Vol 77 (1) ◽  
pp. 9-15 ◽  
Author(s):  
Hélène Catenoix ◽  
François Mauguière ◽  
Alexandra Montavont ◽  
Philippe Ryvlin ◽  
Marc Guénot ◽  
...  

Abstract BACKGROUND: Radiofrequency thermocoagulation (RFTC) guided by stereoelectroencephalography (SEEG) has proved to be a safe palliative method to reduce seizure frequency in patients with drug-resistant partial epilepsy. In malformation of cortical development (MCD), increasing the number of implanted electrodes over that needed for mapping of the epileptogenic zone could help to maximize RFTC efficiency. OBJECTIVE: To evaluate the benefit of SEEG-guided RFTC in 14 patients suffering from drug-resistant epilepsy related to MCD located in functional cortical areas or in regions poorly accessible to surgery. METHODS: Ten men and 4 women were treated by RFTC. Thermolesions were produced by applying a 50-V, 120-mA current for 10 to 30 seconds within the epileptogenic zone as identified by the SEEG investigation. RESULTS: An average of 25.8 ± 17.5 thermolesions were made per procedure. The median follow-up after the procedure was 41.7 months. Sixty-four percent of the patients experienced a long-term decrease in seizure frequency of >50%, of whom 6 (43%) presented long-lasting freedom from seizure. When a focal low-voltage fast activity was present at seizure onset on SEEG recordings, 87.5% of patients were responders or seizure free. All of the patients in whom electric stimulation reproduced spontaneous seizures were responders. CONCLUSION: Our results show the good benefit-risk ratio of the SEEG-guided procedure for patients suffering from MCD in whom surgery is risky. This study identifies 2 factors, focal low-voltage, high-frequency activity at seizure onset and lowered epileptogenic threshold in the coagulated area, that could be predictive of a favorable seizure outcome after RFTC.


2022 ◽  
Author(s):  
Adam Khalifa ◽  
Seyed Mahdi Abrishami ◽  
Mohsen Zaeimbashi ◽  
Alexander D. Tang ◽  
Brian Coughlin ◽  
...  

Non-invasive stimulation of deep brain regions has been a major goal for neuroscience and neuromodulation in the past three decades. Transcranial magnetic stimulation (TMS), for instance, cannot target deep regions in the brain without activating the overlying tissues and has a poor spatial resolution. In this manuscript, we propose a new concept that relies on the temporal interference of two high-frequency magnetic fields generated by two electromagnetic solenoids. To illustrate the concept, custom solenoids were fabricated and optimized to generate temporal interfering electric fields for rodent brain stimulation. C-Fos expression was used to track neuronal activation. C-Fos expression was not present in regions impacted by only one high-frequency magnetic field indicating ineffective recruitment of neural activity in non-target regions. In contrast, regions impacted by two fields that interfere to create a low-frequency envelope display a strong increase in c-Fos expression. Therefore, this magnetic temporal interference solenoid-based system provides a framework to perform further stimulation studies that would investigate the advantages it could bring over conventional TMS systems.


2020 ◽  
Author(s):  
Ezequiel Mikulan ◽  
Simone Russo ◽  
Sara Parmigiani ◽  
Simone Sarasso ◽  
Flavia Maria Zauli ◽  
...  

AbstractPrecisely localizing the sources of brain activity as recorded by EEG is a fundamental procedure and a major challenge for both research and clinical practice. Even though many methods and algorithms have been proposed, their relative advantages and limitations are still not well established. Moreover, these methods involve tuning multiple parameters, for which no principled way of selection exists yet. These uncertainties are emphasized due to the lack of ground-truth for their validation and testing. Here we provide the first open dataset that comprises EEG recorded electrical activity originating from precisely known locations inside the brain of living humans. High-density EEG was recorded as single-pulse biphasic currents were delivered at intensities ranging from 0.1 to 5 mA through stereotactically implanted electrodes in diverse brain regions during pre-surgical evaluation of patients with drug-resistant epilepsy. The uses of this dataset range from the estimation of in vivo tissue conductivity to the development, validation and testing of forward and inverse solution methods.


2016 ◽  
Author(s):  
Alexander Opitz ◽  
Arnaud Falchier ◽  
Chao-Gan Yan ◽  
Erin Yeagle ◽  
Gary Linn ◽  
...  

AbstractTranscranial electric stimulation (TES) is an emerging technique, developed to non-invasively modulate brain function. However, the spatiotemporal distribution of the intracranial electric fields induced by TES remains poorly understood. In particular, it is unclear how much current actually reaches the brain, and how it distributes across the brain. Lack of this basic information precludes a firm mechanistic understanding of TES effects. In this study we directly measure the spatial and temporal characteristics of the electric field generated by TES using stereotactic EEG (s-EEG) electrode arrays implanted in cebus monkeys and surgical epilepsy patients. We found a small frequency dependent decrease (10%) in magnitudes of TES induced potentials and negligible phase shifts over space. Electric field strengths were strongest in superficial brain regions with maximum values of about 0.5 mV/mm. Our results provide crucial information for the interpretation of human TES studies and the optimization and design of TES stimulation protocols. In addition, our findings have broad implications concerning electric field propagation in non-invasive recording techniques such as EEG/MEG.


2019 ◽  
Author(s):  
Jose Gomez-Tames ◽  
Atsushi Hamasaka ◽  
Akimasa Hirata ◽  
Ilkka Laakso ◽  
Mai Lu ◽  
...  

AbstractDeep transcranial magnetic stimulation (dTMS) is a non-invasive technique used in treating depression. In this study, we computationally evaluate group-level dosage during dTMS with the aim of characterizing targeted deep brain regions to overcome the limitation of using individualized head models to characterize coil performance in a population.We use an inter-subject registration method adapted to deep brain regions that enable projection of computed electric fields (EFs) from individual realistic head models (n= 18) to the average space of deep brain regions. The computational results showed consistent group-level hotspots of the EF in deep brain region with intensities between 20%-50% of the maximum EF in the cortex. Large co-activation in other brain regions was confirmed while half-value penetration depth from the cortical surface was smaller than 2 cm. The halo figure-8 assembly and halo circular assembly coils induced the highest EFs for caudate, putamen, and hippocampus.Generalized induced EF maps of deep regions show target regions despite inter-individual difference. This is the first study that visualizes generalized target regions during dTMS and provides a method for making informed decisions during dTMS interventions in clinical practice.


2016 ◽  
Vol 1 (1) ◽  
pp. 4
Author(s):  
Marymol Koshy ◽  
Bushra Johari ◽  
Mohd Farhan Hamdan ◽  
Mohammad Hanafiah

Hypertrophic cardiomyopathy (HCM) is a global disease affecting people of various ethnic origins and both genders. HCM is a genetic disorder with a wide range of symptoms, including the catastrophic presentation of sudden cardiac death. Proper diagnosis and treatment of this disorder can relieve symptoms and prolong life. Non-invasive imaging is essential in diagnosing HCM. We present a review to deliberate the potential use of cardiac magnetic resonance (CMR) imaging in HCM assessment and also identify the risk factors entailed with risk stratification of HCM based on Magnetic Resonance Imaging (MRI).


The Analyst ◽  
2016 ◽  
Vol 141 (5) ◽  
pp. 1587-1610 ◽  
Author(s):  
Zou Xiaobo ◽  
Huang Xiaowei ◽  
Malcolm Povey

The main food quality traits of interest using non-invasive sensing techniques are sensory characteristics, chemical composition, physicochemical properties, health-protecting properties, nutritional characteristics and safety. A wide range of non-invasive sensing techniques, from optical, acoustical, electrical, to nuclear magnetic, X-ray, biosensor, microwave and terahertz, are organized according to physical principle.


Sign in / Sign up

Export Citation Format

Share Document