scholarly journals Evaluation of 11 DNA Automated Extraction Protocols for the Detection of the 5 Mains Candida Species from Artificially Spiked Blood

2021 ◽  
Vol 7 (3) ◽  
pp. 228
Author(s):  
Estelle Menu ◽  
Jordi Landier ◽  
Elsa Prudent ◽  
Stéphane Ranque ◽  
Coralie L’Ollivier

The molecular detection of Candida plays an important role in the diagnosis of candidaemia, a major cause of morbidity and mortality. The sensitivity of this diagnosis is partly related to the efficiency of yeast DNA extraction. In this monocentric study, we investigated the suitability of 11 recent automated procedures for the extraction of low and high amounts of Candida DNA from spiked blood. The efficacy of the DNA extraction procedures to detect Candida spp. in blood samples ranged from 31.4% to 80.6%. The NucliSENSTM easyMAGTM procedure was the most efficient, for each species and each inoculum. It significantly outperformed the other procedures at the lower Candida inocula mimicking the clinical setting. This study highlighted a heterogeneity in DNA extraction efficacy between the five main Candida species (Candida albicans, Candida glabrata, Candida parapsilosis, Candida tropicalis and Candida krusei). Up to five automated procedures were appropriate for C. krusei DNA extraction, whereas only one method yielded an appropriate detection of low amount of C. tropicalis. In the era of the syndromic approach to bloodstream infection diagnosis, this evaluation of 11 automated DNA extraction methods for the PCR diagnosis of candidaemia, puts the choice of an appropriate method in routine diagnosis within the reach of laboratories.

2020 ◽  
Vol 15 (12) ◽  
pp. 1139-1145
Author(s):  
Aroa Silgado ◽  
Zaira Moure ◽  
Maykon T de Oliveira ◽  
Núria Serre-Delcor ◽  
Fernando Salvador ◽  
...  

Aim: This work aimed to compare the sensitivity of four protocols for the detection of Trypanosoma cruzi DNA in 98 blood samples from chronic Chagas disease patients. Materials & methods: Two DNA extraction (automated and manual) methods and two T. cruzi satellite DNA qPCRs (with a recent design and the usually used set of primers) were analyzed. Results: Both DNA extraction methods and qPCR assays tested in this work gave comparable qualitative results, although the lowest Ct values were obtained when samples were analyzed using the new set of primers for T. cruzi satellite DNA. Conclusion: Our results encourage the implementation of automated DNA extraction systems and the new T. cruzi qPCR for the molecular diagnostics and treatment response monitoring of chronic Chagas disease patients.


2016 ◽  
Vol 52 ◽  
pp. 171-176
Author(s):  
M. Palkina ◽  
O. Metlitska

The aim of the research – adaptation, optimization and using of existing DNA extraction methods from bees’ biological material with the reagent «Chelex-100" under complex economic conditions of native laboratories, which will optimize labour costs and improve the economic performance of DNA extraction protocol. Materials and methods. In order to conduct the research the samples of honey bees’ biological material: queen pupae exuviae, larvae of drone brood, some adult bees’ bodies (head and thorax) were selected. Bowl and drone brood were obtained from the experimental bee hives of Institute of Apiculture nd. a. P. I. Prokopovich of NAAS. DNA extraction from biosamples of Apis mellifera ssp. was carried out using «Chelex-100®» ion exchange resin in different concentrations and combinations. Before setting tests for determination of quantitative and quality indexes, dilution of DNA samples of the probed object was conducted in ratio 1:40. The degree of contamination with protein and polysaccharide fractions (OD 260/230), quantitative content of DNA (OD 260/280) in the extracted tests were conducted using spectrophotometer of «Biospec – nano» at the terms of sample volume in 2 µl and length of optical way in 0,7 mm [7]. Verification of DNA samples from biological material of bees, isolated by «Chelex-100®», was conducted after cold keeping during 24 hours at 20°C using PСR with primaries to the fragment of gene of quantitative trait locus (QTL) Sting-2 of next structure [8]:  3' – CTC GAC GAG ACG ACC AAC TTG – 5’; 3' – AAC CAG AGT ATC GCG AGT GTT AC – 5’ Program of amplification: 94 °C – 5 minutes – 1 cycle; 94 °C – 1 minute, 57°C – 1 minute, 72 °C – 2 minutes – 30 cycles; elongation after 72°C during 2 minutes – 1 cycle. The division of obtained amplicons was conducted by gel electrophoresis at a low current – 7 µÀ, in 1,5 % agarose gel (Sigma ®) in TAE buffer [7]. The results. At the time of optimization of DNA isolation methods, according to existing methods of foreign experts, it was found optimal volume of ion exchange resin solution was in the proposed concentration: instead of 60 µl of solution used 120 µl of «Chelex-100®», time of incubation was also amended from 30 minutes to 180 minutes [9]. The use of the author's combination of method «Chelex-100®» with lysis enzymes, proteinase K and detergents (1M dithiothreitol), as time of incubation was also amended, which was reduced to 180 minutes instead of the proposed 12 hours [10]. Changes in quality characteristics of obtained DNA in samples after reduction in incubation time were not found. Conclusions. The most economical method of DNA isolation from bees’ biological material is 20% solution of «Chelex-100» ion exchange resin with the duration of the incubation period of 180 minutes. It should also be noted that the best results can be obtained from exuviae, selected immediately after the queen’s exit from bowl, that reduces the likelihood of DNA molecules destruction under the influence of nucleases activation, but not later than 12 hours from release using the technology of isolated obtain of queens.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1989
Author(s):  
Laura Téblick ◽  
Severien Van Keer ◽  
Annemie De Smet ◽  
Pierre Van Damme ◽  
Michelle Laeremans ◽  
...  

The potential of first-void (FV) urine as a non-invasive liquid biopsy for detection of human papillomavirus (HPV) DNA and other biomarkers has been increasingly recognized over the past decade. In this study, we investigated whether the volume of this initial urine stream has an impact on the analytical performance of biomarkers. In parallel, we evaluated different DNA extraction protocols and introduced an internal control in the urine preservative. Twenty-five women, diagnosed with high-risk HPV, provided three home-collected FV urine samples using three FV urine collection devices (Colli-Pee) with collector tubes that differ in volume (4, 10, 20 mL). Each collector tube was prefilled with Urine Conservation Medium spiked with phocine herpesvirus 1 (PhHV-1) DNA as internal control. Five different DNA extraction protocols were compared, followed by PCR for GAPDH and PhHV-1 (qPCR), HPV DNA, and HBB (HPV-Risk Assay), and ACTB (methylation-specific qPCR). Results showed limited effects of collection volume on human and HPV DNA endpoints. In contrast, significant variations in yield for human endpoints were observed for different DNA extraction methods (p < 0.05). Additionally, the potential of PhHV-1 as internal control to monitor FV urine collection, storage, and processing was demonstrated.


2018 ◽  
Vol 1 (3) ◽  
pp. 27 ◽  
Author(s):  
Džiuginta Jakočiūnė ◽  
Arshnee Moodley

Bacteriophages (phages) are intensely investigated as non-antibiotic alternatives to circumvent antibiotic resistance development as well as last resort therapeutic options against antibiotic resistant bacteria. As part of gaining a better understanding of phages and to determine if phages harbor putative virulence factors, whole genome sequencing is used, for which good quality phage DNA is needed. Traditional phage DNA extraction methods are tedious and time consuming, requiring specialized equipment e.g., an ultra-centrifuge. Here, we describe a quick and simple method (under four hours) to extract DNA from double stranded DNA (dsDNA) phages at titers above 1.0 × 1010 plaque-forming units (PFU)/mL. This DNA was suitable for library preparation using the Nextera XT kit and sequencing on the Illumina MiSeq platform.


2007 ◽  
Vol 68 (1) ◽  
pp. S80
Author(s):  
Victoriano J. Leon ◽  
Alberto J. Leon ◽  
Juan Luis Garcia

Sign in / Sign up

Export Citation Format

Share Document