scholarly journals Competitive Binding of Bilirubin and Fatty Acid on Serum Albumin Affects Wear of UHMWPE

Lubricants ◽  
2020 ◽  
Vol 8 (5) ◽  
pp. 53
Author(s):  
Spencer Fullam ◽  
Jade He ◽  
Caroline S. Scholl ◽  
Thomas M. Schmid ◽  
Markus A. Wimmer

Total Joint Replacement (TJR) devices undergo standardized wear testing in mechanical simulators while submerged in a proteinaceous testing solution to mimic the environmental conditions of artificial joints in the human body. Typically, bovine calf serum is used to provide the required protein content. However, due to lot-to-lot variability, an undesirable variance in testing outcome is observed. Based on an earlier finding that yellowish-orange serum color saturation is associated with wear rate, we examined potential sources of this variability, by running a comparative wear test with bilirubin; hemin; and a fatty acid, oleic acid, in the lubricant. All these compounds readily bind to albumin, the most abundant protein in bovine serum. Ultrahigh molecular weight polyethylene (UHMWPE) pins were articulated against CoCrMo discs in a pin-on-disc tribometer, and the UHMWPE wear rates were compared between lubricants. We found that the addition of bilirubin increased wear by 121%, while hemin had a much weaker, insignificant effect. When added at the same molar ratio as bilirubin, the fatty acid tended to reduce wear. Additionally, there was a significant interaction with respect to bilirubin and hemin in that UHMWPE wear rate decreased with increasing fatty acid concentration. We believe the conformational change in albumin by binding bilirubin makes it more likely to form molecular bridges between UHMWPE and the metal counterface, thus increasing adhesive wear. However, fatty acids compete for binding sites on albumin, and can prevent this conformational change. Hence, the protein is stabilized, and the chance for albumin to form bridges is lowered. Ultimately, UHMWPE wear rate is driven by the competitive binding of bilirubin and fatty acid to albumin.

2003 ◽  
Vol 125 (3) ◽  
pp. 638-642 ◽  
Author(s):  
Vesa Saikko

In the wear testing of prosthetic joints, the optimal lubricant protein concentration is disputed. The effect of protein concentration of calf serum based lubricant on the wear of ultra-high molecular weight polyethylene against CoCr was studied with a 12-station, circularly translating pin-on-disk device. The wear factor first steeply increased with increasing concentration, reached a peak at 10–20 mg/ml, and then slowly decreased. Below 20 mg/ml, the wear mechanisms were not entirely representative of clinical wear. Above this value, the morphology of the UHMWPE wear surface resembled that of retrieved cups. The results indicated that the concentration should not be below 20 mg/ml. The scope of this recommendation is discussed.


Author(s):  
S L Smith ◽  
D Dowson ◽  
A A J Goldsmith

It has been found that a remarkable reduction in the wear of metal-on-metal hip joints can be achieved by simply increasing the diameter of the joint. A tribological evaluation of metal-on-metal joints of 16, 22,225, 28 and 36 mm diameter was conducted in 25 per cent bovine serum using a hip joint simulator. The joints were subject to dynamic motion and loading cycles simulating walking for both lubrication and wear studies. For each size of joint in the lubrication study, an electrical resistivity technique was used to detect the extent of surface separation through a complete walking cycle. Wear of each size of joint was measured gravimetrically in wear tests of at least 2 × 106 cycles duration. Joints of 16 and 22.225mm diameter showed no surface separation in the lubrication study. This suggested that wear would be proportional to the sliding distance and hence joint size in this boundary lubrication regime. A 28 mm diameter joint showed only limited evidence of surface separation suggesting that these joints were operating in a mixed lubrication regime. A 36 mm diameter joint showed surface separation for considerable parts of each walking cycle and hence evidence of the formation of a protective lubricating film. Wear testing of 16 and 22.225mm diameter metal-on-metal joints gave mean wear rates of 4.85 and 6.30mm3/106 cycles respectively. The ratio of these wear rates, 0.77, is approximately the same as the joint diameters ratio, 16/22.225 or 0.72, as expected from simple wear theory for dry or boundary lubrication conditions. No bedding-in was observed with these smaller diameter joints. For the 28 mm diameter joint, from 0 to 2 × 106 cycles, the mean wear rate was 1.62 mm3/106 cycles as the joints bedded-in. Following bedding-in, from 2.0 × 106 to 4.7 × 106 cycles, the wear rate was 0.54mm3/106 cycles. As reported previously by Goldsmith in 2000 [1], the mean steady state wear rate of the 36 mm diameter joints was lower than those of all the other diameters at 0.07 mm3/106 cycles. For a range of joints of various diameters, subjected to identical test conditions, mean wear rates differed by almost two orders of magnitude. This study has demonstrated that the application of sound tribological principles to prosthetic design can reduce the wear of metal-on-metal joints, using currently available materials, to a negligible level.


Author(s):  
V Saikko

Until recently, wear studies of orthopaedic biomaterials have suffered from inadequate testing capacity and high standard deviation (SD) of results. In the present article, the previously validated 100-station hip wear simulator, the SuperCTPOD, is evaluated with regard to its capability of producing statistically significant differences in mean wear rates. SuperCTPOD wear tests were done for 38 different types of polyethylene pins against polished CoCr discs with diluted calf serum lubrication. A total of 200 pins were worn in two consecutive tests of 6 weeks, duration each. The sample size varied from four to six. The mean wear rates of the samples ranged from 0.52 to 77.1 mg per one million cycles. On the average, the SD of the wear rate was 4.2 per cent of the mean value (range 1–8.5 per cent). A difference in the mean wear rates below 5 per cent was large enough to be statistically significant ( p <0.05) in 21 comparisons between two samples, the lowest statistically significant mean difference being 3.2 per cent. In conclusion, the high capacity and the low SD of the wear rate make the SuperCTPOD wear test system unparalleled in efficiency. The observations regarding the effect of crosslinking and molecular weight on polyethylene wear resistance were in agreement with studies published earlier.


2011 ◽  
Vol 325 ◽  
pp. 339-344 ◽  
Author(s):  
Jim N. Boland ◽  
Xing S. Li ◽  
D. Hay ◽  
Colin M. MacRae ◽  
S. Elbracht ◽  
...  

Variability in the abrasive wear of PCD coatings on cemented WC substrates has been investigated. Six samples of PCD coated carbides were tested in a wear testing rig. The PCD coated element was used to turn an industry standard vitrified bonded corundum grinding wheel. The wear rate was measured as the weight loss of the cutting element per cubic metre of grinding wheel machined during the test. Two grades of cutting elements were observed. One grade had wear rates between 6 and 7.3 g/m³ but of the three poor quality samples, only one valid test was made realising wear rate of ~7,800 g/m³. The microstructures of the samples were studied using SEM, X-ray imaging, neutron diffraction and XRD. SEM images revealed differences in the volume percentage of diamonds in the two grades and the XRD scans highlighted the variable distribution of the diamond phase in the coating. Estimates of the residual stresses in a good and poor quality samples indicated significantly higher compressive stresses in the good quality versus poor quality coating. These results have revealed two extremes in the wear rates of these PCD coated carbides. It is suggested that the difference in diamond content between the two grades is not sufficient to account for the 3 orders-of-magnitude difference in the observed wear rates. However, the presence of intrusive veins of carbide material in the coatings, especially around the curved cutting tip, suggested that the macroscopic defects observed in the x-ray and SEM images were the major cause of the high wear rates in the poor quality sample.


1999 ◽  
Author(s):  
Jeff A. Sprague ◽  
Willard L. Sauer

Abstract The effect of adding a second axis of motion was investigated for pin-on-disk wear testing of ultra-high-molecular-weight polyethylene (UHMWPE) for orthopaedic implant applications. In addition to linear reciprocation of the UHMWPE or metal disk, axial rotation of the metal or UHMWPE pin was conducted. The added rotation reproduces the cross-shear on the UHMWPE surface that is generated in clinically relevant wear simulator tests and in vivo. The wear rates that result from the multi-axis pin-on-disk tests are significantly higher (one to two orders of magnitude) than those seen in the linear-only tests. This supports the findings of other researchers (Bragdon et al., 1996; McKellop, 1995; Walker et al., 1996; Wang et al. 1997) in that the application of nonlinear motion increases the wear of UHMWPE substantially. This is further validated by the comparison of a hip simulator wear test conducted with three axes of motion — rotation, flexion, and abduction — to a test conducted with two axes of motion — rotation and flexion. The absence of the abduction eliminated a significant degree of nonlinear motion (cross-shear) and, consequently, the wear rate was significantly lower than that seen in the test with abduction.


2007 ◽  
Vol 7 (2) ◽  
pp. 165-173 ◽  
Author(s):  
Jeremy J. Rawlinson ◽  
Karan P. Punga ◽  
Kirk L. Gunsallus ◽  
Donald L. Bartel ◽  
Timothy M. Wright

Object. An understanding of the wear potential of total disc replacements (TDRs) is critical as these new devices are increasingly introduced into clinical practice. The authors analyzed the wear potential of a ProDisc-L implant using an adaptive finite element (FE) technique in a computational simulation representing a physical wear test. Methods. The framework for calculating abrasive wear, first validated using a model of a total hip replacement (THR), was then used to model the ProDisc-L polyethylene component that is fixed to the inferior endplate and articulates with the rigid superior endplate. Proposed standards for spine wear testing protocols specified the inputs of flexion–extension (6/−3°), lateral bending (± 2°), axial twist (± 1.5°), and axial load (200–1750 N or 600–2000 N) applied to the model through 10 million simulation cycles. The model was calibrated with a wear coefficient determined from an experimental wear test. Implicit FE analyses were then performed for variations in coefficient of friction, polyethylene elastic modulus, radial clearance, and polyethylene component thickness to investigate their effects on wear. Results. Using the initial loading protocol (single-peaked axial load profile of 300–1750 N) from the experimental wear test, the polyethylene wear rate was 9.82 mg per million cycles. When a double-peaked loading profile (600–2000 N) was applied, the wear rate increased to 11.77 mg per million cycles. Parametric design variations produced only small changes in wear rates for this simulation. Conclusions. The chosen design variables had little effect on the resultant wear rates. The comparable wear rate for the THR validation analysis was 16.17 mg per million cycles, indicating that, using this framework, the wear potential of the TDR was equivalent to, if not better, than the THR using joint-specific loading standards.


Author(s):  
T Schwenke ◽  
C Kaddick ◽  
E Schneider ◽  
M A Wimmer

Wear of total knee replacements is determined gravimetrically in simulator studies. A mix of bovine serum, distilled water, and additives is intended to replicate the lubrication conditions in vivo. Weight gain due to fluid absorption during testing is corrected using a load soak station. In this study, three sets of ultrahigh molecular weight polyethylene tibial plateau were tested against highly polished titanium condyles. Test 1 was performed in two different institutions on the same simulator according to the standard ISO 14243-1, using two testing lubricants. Test 2 and test 3 repeated both previous test sections. The wear and load soak rates changed significantly with the lubricant. The wear rate decreased from 16.9 to 7.9 mg weight loss per million cycles when switching from fluid A to fluid B. The weight gain of the load soak specimen submersed in fluid A was 6.1 mg after 5 × 106 cycles, compared with 31.6 mg for the implant in fluid B after the same time period. Both lubricants were mixed in accordance with ISO 14243 ( Implants for surgery - wear of total knee-joint prostheses), suggesting that calf serum should be diluted to 25 ± 2 per cent with deionized water and a protein mass concentration of not less than 17 g/1. The main differences were the type and amount of additives that chemically stabilize the lubricant throughout the test. The results suggest that wear rates can only be compared if exactly the same testing conditions are applied. An agreement on detailed lubricant specifications is desirable.


2016 ◽  
Vol 841 ◽  
pp. 15-20
Author(s):  
Gheorghe Matache ◽  
Alexandru Paraschiv ◽  
Cristian Puscasu

The wear behaviour of thick molybdenum coatings deposited by electric arc thermal spray on steel support was investigated by micro-abrasion, a relatively recent introduced method for small scale wear testing. The wear mechanisms and wear rates without coatings penetration were investigated with respect of time corresponding to primary and secondary wear stages. The micro-abrasion of Mo coatings using SiC abrasive slurry have been discussed and wear scar characteristics were evaluated based on the experimentally results. The worn surfaces of the tested specimen were examined by SEM and the specific wear rate was calculated from experimental data. For the testing durations used it was identified the change from grooving to rolling wear corresponding to the transition of wear mode from two-body to three body-abrasion.


1981 ◽  
Vol 10 (3) ◽  
pp. 137-142 ◽  
Author(s):  
R W Treharne ◽  
R W Young ◽  
S R Young

This paper describes a new method for testing total knee prostheses under simulated in vivo conditions. Previous knee simulator work has been summarized and described. The major variables of testing are also described in detail. The results of wear testing five types of knee prostheses were that the wear rate was nearly an inverse relationship with contact area— knees with a higher contact area had lower wear rates.


2020 ◽  
Vol 23 (4) ◽  
pp. 40-43
Author(s):  
Hadia Kadhim Judran ◽  

Two types of alloy (Steel and Kovar) were prepared and machined as half ring. Wear testing system was used to determine the wear rate of specimens without any lubrication, and after modified wear testing system which was used to test the specimen under lubricant condition. The wear rate wasdetermined by using weighing method and then calculated. The results shows the values of wear rate of kovar specimens are higher than the values of wear rate for steel specimens in both two cases with and without lubrication. The result of wear rates wereplotted as function of sliding time at a fixed normal load.