scholarly journals Design and Simulation Study of the Induction Heated Injection Mold with Sliders

Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7476
Author(s):  
Paweł Muszyński ◽  
Przemysław Poszwa ◽  
Krzysztof Mrozek ◽  
Michał Zielinski ◽  
Piotr Dalewski ◽  
...  

In order to increase the quality of the products manufactured by injection molding, RTC technology can be used to achieve higher mold temperatures. As a result, the path of the injected melt can be extended, allowing the production of parts with more complex shapes and greater length. Induction heating allows heating only selected forming surfaces of the mold which increases the speed and efficiency of the process. This paper presents the concept of a detachable inductor integrated with sliders to enable the application of this technology in an injection mold with sliders, along with the theoretical model used to perform the tests. First, the effect of the magnetic concentrator shape on the process was analyzed. This was followed by a simulation study of the influence of process parameters: heating time, frequency, and electric current. An extensive analysis of the test results of the temperature distribution on the insert allowed for the selection of parameter sets that would enable obtaining the desired surface temperature without a major increase in process time. The results of simulation studies confirm the possible applications and present the range of parameters for obtaining the optimal process.

2019 ◽  
Vol 9 (01) ◽  
pp. 47-54
Author(s):  
Rabbai San Arif ◽  
Yuli Fitrisia ◽  
Agus Urip Ari Wibowo

Voice over Internet Protocol (VoIP) is a telecommunications technology that is able to pass the communication service in Internet Protocol networks so as to allow communicating between users in an IP network. However VoIP technology still has weakness in the Quality of Service (QoS). VOPI weaknesses is affected by the selection of the physical servers used. In this research, VoIP is configured on Linux operating system with Asterisk as VoIP application server and integrated on a Raspberry Pi by using wired and wireless network as the transmission medium. Because of depletion of IPv4 capacity that can be used on the network, it needs to be applied to VoIP system using the IPv6 network protocol with supports devices. The test results by using a wired transmission medium that has obtained are the average delay is 117.851 ms, jitter is 5.796 ms, packet loss is 0.38%, throughput is 962.861 kbps, 8.33% of CPU usage and 59.33% of memory usage. The analysis shows that the wired transmission media is better than the wireless transmission media and wireless-wired.


Author(s):  
H Eyigor ◽  
E A Cetinkaya ◽  
D T Coban ◽  
G Ozturk ◽  
Ö Erdem

Abstract Objective External dacryocystorhinostomy is thought to cause mucociliary dysfunction by damaging the mucosa, in turn affecting ciliary activity and mucus quality. This study investigated the effect of external dacryocystorhinostomy on sinonasal function. Methods Patients scheduled for unilateral external dacryocystorhinostomy who underwent endoscopic nasal examination and paranasal sinus computed tomography were included in this study. A saccharine test was performed on the planned surgical side and the mucociliary clearance time was determined. The sinonasal quality of life was measured in all patients, pre-operatively and at six months post-operatively, using the Sino-Nasal Outcome Test-22. The Lund–Kennedy endoscopic score was also determined in all patients, both pre- and post-operatively. Results The study comprised 28 patients (22 females and 6 males). A statistically significant difference was found between the pre- and post-operative saccharine test results (p = 0.006), but not between the pre- and post-operative Sino-Nasal Outcome Test-22 scores (p > 0.05). Conclusion This study is one of only a few to investigate the effect of external dacryocystorhinostomy on sinonasal function. The results showed that external dacryocystorhinostomy impairs mucociliary clearance. The surgical procedure is well tolerated and does not significantly change nasal symptom scores.


2021 ◽  
pp. 004051752110308
Author(s):  
Yang Liu ◽  
Zhong Xiang ◽  
Xiangqin Zhou ◽  
Zhenyu Wu ◽  
Xudong Hu

Friction between the tow and tool surface normally happens during the tow production, fabric weaving, and application process and has an important influence on the quality of the woven fabric. Based on this fact, this paper studied the influence of tension and relative velocity on the three kinds of untwisted-glass-fiber tow-on-roller friction with a Capstan-based test setup. Furthermore, an improved nonlinear friction model taking both tension and velocity into account was proposed. According to statistical test results, firstly, the friction coefficient was found to be positively correlated with tension and relative velocity. Secondly, tension and velocity were complementary on the tow-on-roller friction behavior, with neither being superior to the other. Thirdly, an improved model was found to present well the nonlinear characteristics between friction coefficient and tension and velocity, and predicational results of the model were found to agree well with the observations from Capstan tests.


2008 ◽  
Vol 54 (11) ◽  
pp. 1872-1882 ◽  
Author(s):  
Eva Nagy ◽  
Joseph Watine ◽  
Peter S Bunting ◽  
Rita Onody ◽  
Wytze P Oosterhuis ◽  
...  

Abstract Background: Although the methodological quality of therapeutic guidelines (GLs) has been criticized, little is known regarding the quality of GLs that make diagnostic recommendations. Therefore, we assessed the methodological quality of GLs providing diagnostic recommendations for managing diabetes mellitus (DM) and explored several reasons for differences in quality across these GLs. Methods: After systematic searches of published and electronic resources dated between 1999 and 2007, 26 DM GLs, published in English, were selected and scored for methodological quality using the AGREE Instrument. Subgroup analyses were performed based on the source, scope, length, origin, and date and type of publication of GLs. Using a checklist, we collected laboratory-specific items within GLs thought to be important for interpretation of test results. Results: The 26 diagnostic GLs had significant shortcomings in methodological quality according to the AGREE criteria. GLs from agencies that had clear procedures for GL development, were longer than 50 pages, or were published in electronic databases were of higher quality. Diagnostic GLs contained more preanalytical or analytical information than combined (i.e., diagnostic and therapeutic) recommendations, but the overall quality was not significantly different. The quality of GLs did not show much improvement over the time period investigated. Conclusions: The methodological shortcomings of diagnostic GLs in DM raise questions regarding the validity of recommendations in these documents that may affect their implementation in practice. Our results suggest the need for standardization of GL terminology and for higher-quality, systematically developed recommendations based on explicit guideline development and reporting standards in laboratory medicine.