Nuclear instrumentation � Housed scintillators � Test methods of light output and intrinsic resolution

2021 ◽  
2016 ◽  
Vol 675-676 ◽  
pp. 764-767
Author(s):  
Akapong Phunpueok ◽  
Voranuch Thongpool ◽  
Wuttichai Chaiphaksa

The study of photon interactions with matter is very important in many fields such as scientific, industry, medical imaging, biological applications, dosimetry, and radiation shielding for their potential use in radiation physics. Scintillating materials become a main part in detection and spectroscopy of high energy photons. The goal of this work is to study an interaction of 662 keV γ-rays with scintillating materials, namely the LYSO(Ce) and BGO crystals. The light output, energy resolution, intrinsic resolution, and photo-fraction of both crystals with the same size of 5x5x3 mm3 were measured using photomultiplier tube (PMT) readout. The result showed that the light yield of the LYSO(Ce) crystal is much more better than that of the BGO crystal, while its photo-fraction is worse than that of the BGO crystal.


Author(s):  
R. Levi-Setti ◽  
J. M. Chabala ◽  
Y. L. Wang

We have shown the feasibility of 20 nm lateral resolution in both topographic and elemental imaging using probes of this size from a liquid metal ion source (LMIS) scanning ion microprobe (SIM). This performance, which approaches the intrinsic resolution limits of secondary ion mass spectrometry (SIMS), was attained by limiting the size of the beam defining aperture (5μm) to subtend a semiangle at the source of 0.16 mr. The ensuing probe current, in our chromatic-aberration limited optical system, was 1.6 pA with Ga+ or In+ sources. Although unique applications of such low current probes have been demonstrated,) the stringent alignment requirements which they imposed made their routine use impractical. For instance, the occasional tendency of the LMIS to shift its emission pattern caused severe misalignment problems.


2001 ◽  
Vol 120 (5) ◽  
pp. A586-A587
Author(s):  
L BEST ◽  
S JO ◽  
V VANZANTEN ◽  
D HALDANE ◽  
V LOO ◽  
...  

1990 ◽  
Vol 64 (03) ◽  
pp. 478-484 ◽  
Author(s):  
Thomas Exner ◽  
Douglas A Triplett ◽  
David A Taberner ◽  
Margaret A Howard ◽  
E Nigel Harris

SummarySix lyophilized plasma samples were sent to 20 “expert” laboratories for assessment of lupus anticoagulant (LA). Four samples contained pooled LA of graded potency mixed with aged normal plasma. One contained LA plus cephalin phospholipid and one contained a nonspecific venom anticoagulant. Sixteen methods were used overall with some participants using up to 8 methods. Results were scored in regard to the known potencies of LA in the samples and other known induced defects.Activated partial thromboplastin time (APTT) tests used by most participants for preliminary screening were relatively sensitive, but non-specific. Platelet or phospholipid neutralization procedures (PNP) appeared to be sensitive and specific but showed a non-linear response to increased LA content. Kaolin clotting time (KCT) tests showed the most sensitive response to increased LA content but the weaker LA were not scored as abnormal by most laboratories as the samples may have contained platelet fragments. Other commonly used tests such as the tissue thromboplastin inhibition (TTI) test and the dilute Russell’s viper venom test (DRVVT) were carried out somewhat inconsistently. The variability in performance of tests in different laboratories indicates that standardization of methodology is urgently required.Generally it seemed that most clotting tests were “bypassed” by the addition of phospholipid to a known LA-positive sample in apparently direct proportion to their sensitivity. Sample preparation, especially prevention of contamination with activated platelets is a vital preliminary part in the assay of LA.