scholarly journals Biochemical Interactions Between Polymeric Resins Used for Occlusal Splints and Saliva A pilot study comparing the CAD/CAM technology and the conventional approach

2019 ◽  
Vol 56 (2) ◽  
pp. 409-412 ◽  
Author(s):  
Marina Melescanu-Imre ◽  
Mihaela Pantea ◽  
Alexandra Totan ◽  
Ana Maria Cristina Tancu ◽  
Maria Greabu ◽  
...  

The CAD/CAM technology has been successfully integrated in clinical and laboratory aspects of dental medicine. The present in vitro study focuses on the biochemical interactions between saliva and three types of polymeric resins for occlusal splints. Dental material samples were produced from 3D printed, milled and self-cured resins and were incubated with saliva samples from 20 healthy volunteers. The results showed that the 3D printed and milled polymeric resins did not produce any significant changes in oxidative stress parameters (uric acid, TAC, GGT, OXSR-1) or inflammatory markers (IL-2, IL-6). On the other hand, the self-cured acrylic resin produced a significant decrease in the salivary TAC and uric acid, the most important antioxidants in saliva, affecting the capacity of saliva to protect the oral environment against oxidative stress.

2020 ◽  
Vol 71 (1) ◽  
pp. 405-410
Author(s):  
Kamel Earar ◽  
Alexandru Andrei Iliescu ◽  
Gabriela Popa ◽  
Andrei Iliescu ◽  
Ioana Rudnic ◽  
...  

CAD/CAM procedures are increasingly used to the manufacturing of 3D-designed PMMA interim dental crowns. The aim of this in vitro study was to compare the internal fit of interim PMMA crowns fabricated by subtractive versus additive CAD/CAM procedures. Starting from a Co-Cr CAD/CAM master abutment model, 20 standardized dental models of dental stone were done by double impression technique. Subsequently two groups of interim PMMA interim crowns, each of them having 10 specimens, were CAM obtained either by milling or 3D printing, using Exocad software package, milling machine Rolland DWX-50, and the 3D printer MoonRay S 100 respectively. An electronic digital caliper Powerfix Profi+ was used for measurements of the chrome cobalt abutment and crowns inner diameter in 4 directions (mesial-distal gingival, buccal-lingual gingival, mesial-distal occlusal, and buccal-lingual occlusal). The null hypothesis that the internal dimensional accuracy of interim PMMA crowns fabricated by DLP additive method would not be different compared to those obtained by milling procedure was rejected since the printed PMMA interim crowns were more accurate. This study concluded that the milled PMMA interim crowns show larger internal dimensional variations than the 3D printed ones. However, the fit variation among interim crowns fabricated by both procedures was statistically non significant, so that both CAM technologies may be equally used in manufacturing process.


2020 ◽  
Vol 75 (6) ◽  
pp. 303-310
Author(s):  
George P Babiolakis ◽  
C Peter Owen

INTRODUCTION: No studies on the marginal gap or internal fit of crowns have reported the effect of non-axial seating which may often occur inadvertently clinically. AIM: Therefore this in vitro study sought to investigate the off-axis seating of CAD/CAM crowns and its effect on the marginal gap and internal fit. METHOD: A standardised crown preparation on a typodont tooth was used to design and mill 30 crowns with a flat occlusal surface. Ten Zirconia (Dentsply Sirona, Germany), 10 Enamic (Vita, Austria), and 10 Brilliant Crios (Coltene, Switzerland) crowns were milled, Ave of each milled with a luting space of 100µm, and Ave of 200µm. The marginal gap was measured in two and three dimensions after luting with silicone on a 3D-printed metal replica. Seating occurred axially, at 5° buccally and 5° lingually. The silicone was used to calculate the internal fit RESULTS: Axial seating with a 100 µm luting space obtained the smallest marginal gap, irrespective of material or luting space. 3D measurements were larger than 2D measurements, but not significantly. The maximum off-axis gap was 117µm, on the opposite side to which pressure was applied. CONCLUSIONS: Care must be taken clinically to ensure that luting takes place in an axial direction only.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed Othman ◽  
Steven Hartman ◽  
Dragan Ströbele ◽  
Jassin Arnold ◽  
von See

Abstract Background The purpose of the presented investigation is to evaluate the resulting torque on loaded 3D printed springs using different coil thickness and length. Methods Specimens were designed and printed using the 3D printer MAX (Asiga, Sydney, Australia) with 3D printable, experimental, flexible material (Code:BM2008, GC, Tokyo, Japan). The specimens were divided into three groups according to spring coil design. Control group (n = 18), length group (n = 19) and thickness group (n = 22). Groups were tested using a Sauter Machine for torque calculation (DB, Grindelwald, Switzerland) in conjunction with a universal testing machine (Zwick Z010, Ulm, Germany) for clock-wise and anti-clockwise testing. Statistical analysis was performed using the Steel–Dwass test to compare median values of the three groups in both testing directions (p < 0.001). Results The highest torque value was determined in the thickness group for both clockwise and anti-clockwise testing directions, achieving 44.00 N/mm and 39.62 N/mm respectively. The length group ranged from 21.65 to 11.04 N/mm in clockwise direction and from 18.04 to 11.38 N/mm in counter-clockwise testing. The control group ranged from 22.72 to 17.18 N/mm in the clock-wise direction while in the anti-clock wise testing it ranged from 21.34 to 16.02 N/mm. Conclusions The amount of torque produced from the computer aided designing/computer aided manufacturing (CAD/CAM) springs is being affected by diameter more than the length design parameter in comparison to the control group. The values of the thickness group are significantly higher than those of the length group (P < 0.001).


2019 ◽  
Vol 56 (3) ◽  
pp. 529-533
Author(s):  
Mihaela Pantea ◽  
Diana Andreea Ighigeanu ◽  
Alexandra Totan ◽  
Maria Greabu ◽  
Daniela Miricescu ◽  
...  

This in vitro study analyses the biochemical interaction between saliva and three types of dental composite resins (a direct resin, an indirect resin and a dual-cure resin used for cementation of indirect dental restorations). The resin samples were obtained following a specific protocol and in line with the producers� recommendations; the resin samples were incubated with saliva samples collected from 19 healthy volunteers. The obtained results showed that the tested composite resins did not produce significant changes in oxidative stress parameters that were analysed (albumin, uric acid, GGT / gamma glutamyl transferase, OXSR-1 / oxidative stress responsive kinase 1) and do not influence the inflammatory salivary status reflected by the levels of IL-6 - an inflammatory marker.


Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4103
Author(s):  
Maite Aretxabaleta ◽  
Alexey Unkovskiy ◽  
Bernd Koos ◽  
Sebastian Spintzyk ◽  
Alexander B. Xepapadeas

Different approaches for digital workflows have already been presented for their use in palatal plates for newborns and infants. However, there is no evidence on the accuracy of CAD/CAM manufactured orthodontic appliances for this kind of application. This study evaluates trueness and precision provided by different CAM technologies and materials for these appliances. Samples of a standard palatal stimulation plate were manufactured using stereolithography (SLA), direct light processing (DLP) and subtractive manufacturing (SM). The effect of material (for SM) and layer thickness (for DLP) were also investigated. Specimens were digitized with a laboratory scanner (D2000, 3Shape) and analyzed with a 3D inspection software (Geomagic Control X, 3D systems). For quantitative analysis, differences between 3D datasets were measured using root mean square (RMS) error values for trueness and precision. For qualitative analysis, color maps were generated to detect locations of deviations within each sample. SM showed higher trueness and precision than AM technologies. Reducing layer thickness in DLP did not significantly increase accuracy, but prolonged manufacturing time. All materials and technologies met the clinically acceptable range and are appropriate for their use. DLP with 100 µm layer thickness showed the highest efficiency, obtaining high trueness and precision within the lowest manufacturing time.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2021 ◽  
Vol 10 (3) ◽  
pp. 391
Author(s):  
Rani D’haese ◽  
Tom Vrombaut ◽  
Geert Hommez ◽  
Hugo De Bruyn ◽  
Stefan Vandeweghe

Purpose: The aim of this in vitro study is to evaluate the accuracy of implant position using mucosal supported surgical guides, produced by a desktop 3D printer. Methods: Ninety implants (Bone Level Roxolid, 4.1 mm × 10 mm, Straumann, Villerat, Switzerland) were placed in fifteen mandibular casts (Bonemodels, Castellón de la Plana, Spain). A mucosa-supported guide was designed and printed for each of the fifteen casts. After placement of the implants, the location was assessed by scanning the cast and scan bodies with an intra-oral scanner (Primescan®, Dentsply Sirona, York, PA, USA). Two comparisons were performed: one with the mucosa as a reference, and one where only the implants were aligned. Angular, coronal and apical deviations were measured. Results: The mean implant angular deviation for tissue and implant alignment were 3.25° (SD 1.69°) and 2.39° (SD 1.42°) respectively, the coronal deviation 0.82 mm (SD 0.43 mm) and 0.45 mm (SD 0.31 mm) and the apical deviation 0.99 mm (SD 0.45 mm) and 0.71 mm (SD 0.43 mm). All three variables were significantly different between the tissue and implant alignment (p < 0.001). Conclusion: Based on the results of this study, we conclude that guided implant surgery using desktop 3D printed mucosa-supported guides has a clinically acceptable level of accuracy. The resilience of the mucosa has a negative effect on the guide stability and increases the deviation in implant position.