Numerical Study of Stiffened Steel Plate Shear Wall with Opening under Horizontal and Vertical Loads

2014 ◽  
Vol 501-504 ◽  
pp. 563-567
Author(s):  
Zong Jing Li ◽  
Gan Ping Shu

When steel plate shear walls (SPSWs) are fitted into a long-span truss system, horizontal and vertical deformation should both be considered to evaluate the seismic performance of the structure. Numerical analysis is conducted to study the seismic performance of stiffened steel plate shear wall with opening subject to horizontal and vertical loading respectively based on a project. Results of the analysis indicate that stress distribution and deformation patterns of SPSW with opening are quite similar under horizontal and vertical loading. Stiffeners around the opening should be stretched to full height or width of the SPSW and strengthened by using larger thickness or width. The grids at the four corners of the opening are recommended to be further strengthened by additional stiffeners. SPSW with opening exhibits good hysteretic performance and energy dissipation in both loading directions.

2015 ◽  
Vol 2015 ◽  
pp. 1-16 ◽  
Author(s):  
Jin-yu Lu ◽  
Lu-nan Yan ◽  
Yi Tang ◽  
Heng-hua Wang

To determine the force mechanism for the steel plate shear wall with slits, the pushover analysis method was used in this study. An estimated equation for the lateral bearing capacity which considered the effect of edge stiffener was proposed. A simplified elastic-plastic analytical model for the stiffened steel slit wall composed of beam elements was presented, where the effects of edge stiffeners were taken into account. The wall-frame analysis model was established, and the geometric parameters were defined. Pushover analysis of two specimens was carried out, and the analysis was validated by comparing the results from the experiment, the shell element model, and a simplified model. The simplified model provided a good prediction of the lateral stiffness and the strength of the steel slit wall, with less than 10% error compared with the experimental results. The mutual effects of the bearing wall and the frame were also predicted correctly. In the end, the seismic performance evaluation of a steel slit wall-frame structure was presented. The results showed that the steel slit wall could prevent the beams and columns from being damaged by an earthquake and that the steel slit wall was an efficient energy dissipation component.


2014 ◽  
Vol 638-640 ◽  
pp. 287-291
Author(s):  
Hai Xia Zhang ◽  
Qi Peng ◽  
Li Xuan Zhao

Shear wall is the main component that resists the lateral force for high-rise buildings. With the rapid development of high-rise buildings, especially the super high-rise buildings, requirements for seismic performance of shear walls have become more sophisticated. This introduction summarizes the commonly used in embedded development and existing problems of steel plate shear wall, which are stiffened steel plate shear wall, non-stiffened steel plate shear wall, composite steel plate shear wall, preventing buckling of steel plate shear wall and low yield point steel plate shear wall.


2013 ◽  
Vol 831 ◽  
pp. 149-152
Author(s):  
Kang Min Lee ◽  
Keun Yeong Oh ◽  
Rui Li ◽  
Liu Yi Chen ◽  
Woo Seok Kim

In the last several decades, coupled shear wall have become recognized as efficient lateral load resisting systems for high-rise structures, increasingly. Coupled shear walls give considerable lateral stiffness and strength as well as providing an architecturally practical structural system. In this paper, in order to observe seismic performance of coupled steel plate shear wall, models of previous study was verified, and coupled shear wall with steel plate was carried out with various parametric analysis. Parametric analysis was performed with various width of bay. As a result, model that aspect ratio of steel plate was close to 1 was the most structurally safe.


2018 ◽  
Vol 7 (4.5) ◽  
pp. 182
Author(s):  
Deepna U ◽  
Arjun S Menon ◽  
S Balamurugan

The consequences of lateral loads like earthquake loads, wind loads and blast forces are achieving utmost concern nowadays. Imparting sufficient strength and stability in counter to the lateral loads is one of the major challenges faced by every designer. Therefore Proper understanding of the Seismic performance of different types of shear walls is necessary for structural engineers so as to safeguard the structure against lateral loads. The present paper describes the comparison of the seismic performance of high rise buildings and optimizing the thickness of RCC shear wall, Steel Plate Shear Wall (SPSW) and composite shear wall for (G+20) stories. The design and analysis of the  building with RCC shear wall, steel plate shear wall and composite shear wall is carried out using software ETABS. Effect of varying thickness of shear panels and comparison of the results of story drift and story shear is presented.  


2018 ◽  
Vol 2018 ◽  
pp. 1-18
Author(s):  
Min Gan ◽  
Yu Yu ◽  
Liren Li ◽  
Xisheng Lu

Four test pieces with different steel plate center-to-center distances and reinforcement ratios are subjected to low-cycle repeat quasistatic loading to optimize properties as failure mode, hysteretic curve, skeleton curve, energy dissipation parameters, strength parameters, and seismic performance of high-strength concrete low-rise shear walls. The embedded steel plates are shown to effectively restrict wall crack propagation, enhance the overall steel ratio, and improve the failure mode of the wall while reducing the degree of brittle failure. Under the same conditions, increasing the spacing between the steel plates in the steel plate concrete shear wall can effectively preserve the horizontal bearing capacity of the shear wall under an ultimate load. The embedded steel plates perform better than concealed bracing in delaying stiffness degeneration in the low-rise shear walls, thus safeguarding their long-term bearing capacity. The results presented here may provide a workable basis for shear wall design optimization.


2021 ◽  
Vol 11 (1) ◽  
pp. 6043-6063
Author(s):  
Ali Jafarian ◽  
Seyed Babak Jafarian

Considering the increase in the current construction process and the future needs of Iran, the necessity to use high-rise buildings for reduction in urbanization costs and optimal use of land will be inevitable in the future. The performance of steel plate shear wall system as a modern global system, which has an effective application in high-rise buildings and also brings economic benefits compared to previous systems, is evaluated in this study. Steel Plate Shear Walls (SPSW) are a new type of system resistant to wind and earthquake lateral loads, which dates back to the 1970s. In this research, eight samples of shear wall with various stiffening arrangements and sections with ST37 and ST52 alloys are modeled. To evaluate the nonlinear dynamic analysis, the samples are subjected to the San Fernando earthquake force and are modeled and analyzed by ABAQUS software based on the finite element theory. The results of analyzing the samples indicate better performance of the system with stiffener in both vertical and horizontal directions. Also, the use of sections with ST52 alloy has improved the performance of the shear wall by approximately 40%.


2018 ◽  
Vol 4 (11) ◽  
pp. 2667
Author(s):  
Hayder Fadhil ◽  
Amer Ibrahim ◽  
Mohammed Mahmood

Corrugated steel plate shear wall (CSPSW) is one of the lateral resistance systems which consists mainly of steel frame (beam and column) with vertical or horizontal corrugated steel plate connected to the frame by weld, bolts or both. This type of steel shear wall characterized by low cost and short construction time with high strength, ductility, initial stiffness and excellent ability to dissipate energy. The aim of this paper is to evaluate the effect of corrugation angle and its direction on the performance of CSPSW under cyclic loading. The Finite element analysis was employed to achieve the research aim. The FE models were validated with experimental data available in the literature. Results reveal that the corrugation angle has a clear influence on initial stiffness, strength, ductility, and energy dissipation of CSPSW. The optimum performance of CSPSW can be obtained with angles of 30o for CSPSW with vertical corrugation and 20o for CSPSW with horizontal corrugation. The use of CSPSW with vertical corrugation provides higher strength, stiffness, and ductility compared to CSPSW with horizontal corrugation. Therefore, it is recommended to use CSPSW with vertical corrugation.