Comparative Study on Filter Methods of Medical Ultrasound Images

2011 ◽  
Vol 341-342 ◽  
pp. 467-471
Author(s):  
Run Xia Ma ◽  
Xu Ming Zhang ◽  
Ming Yue Ding ◽  
Qi Liu

This paper presents a comparative study on six despeckling methods such as modified hybrid median filter, gabor filter, speckle reducing anisotropic diffusion, homomorphic filter, non-local mean filter and squeeze box filter. We select eight objective evaluation parameters, such as signal-to-ratio, contrast signal–to–noise ratio, figure of merit, least absolute error, peak signal-to-noise ratio, edge protection factor, quantitative parameters of despeckling, signal-to-minimum mean square error ratio, to quantify the performance of these filters. The comparative study will provide a good guidance for selecting a suitable filter in the ultrasound image processing.

2021 ◽  
Vol 11 (1) ◽  
pp. 399-410
Author(s):  
Kaitheri Thacharedath Dilna ◽  
Duraisamy Jude Hemanth

Abstract Ultrasonography is an extensively used medical imaging technique for multiple reasons. It works on the basic theory of echoes from the tissues under consideration. However, the occurrence of signal dependent noise such as speckle destroys utility of ultrasound images. Speckle noise is subject to the composition of image tissue and parameters of image. It reduces the effectiveness of many image processing steps and decreases human perception of fine details form ultrasound images. In many medical image processing methods, despeckling is used as the preprocessing step before segmentation and feature extraction. Many speckle reduction filters are proposed but while combining many techniques some speckle diagnostic information should be preserved. Removal of speckle noise from ultrasound image by preserving edges and added features is a great challenging task in ultrasound image restoration. This paper aims at a comprehensive description and comparison of reduction of speckle noise of ultrasound fibroid image. Many filters are applied on ultrasound scanned images and the performance is marked in terms of some statistical measures. Even though several despeckling filters are there for speckle reduction, all are not good for ultrasound scanned images. A comparison of quality measures such as mean square error, peak signal-to-noise ratio, and signal-to-noise ratio is done in ultrasound images in despeckling.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Wangyan Jin ◽  
Ling Dai ◽  
Liuyan Ge ◽  
Xuhua Huang ◽  
Guanhua Xu ◽  
...  

This study aimed to analyze the application of ultrasound images of lung recruitment (LR) nursing treatment guided by positive-end expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS). An ultrasound image enhancement algorithm (UIEA) wavelet transform (WT) was constructed, and the soft threshold (ST) and adjacent region average (ARA) were introduced for simulation comparison. In addition, the signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), and running time were undertaken as the evaluation indexes. The WT algorithm was applied to the ultrasound images of 85 ARDS patients before and after PEEP recruitment. The mean artery pressure (MAP), heart rate (HR), and central venous pressure (CVP), peak inspiratory pressure (Ppeak), mean inspiratory pressure (Pmean), dynamic lung compliance (DLC), PCO2, and PaO2/FiO2 of the patients were recorded before and after the LR. The results showed that the signal-to-noise ratio (SNR) (19.67 ± 3.15 dB) and PSNR (23.08 ± 2.08 dB) of the images enhanced by the WT algorithm were much higher than those of ST (13.88 ± 2.74 dB and 14.62 ± 1.76 dB, respectively) and ARA (14.96 ± 3.06 dB and 15.11 ± 1.94 dB, respectively), while the running time was in adverse ( P < 0.05 ); the HR and CVP of patients after LR nursing treatment were increased greatly, while the MAP was in the opposite case ( P < 0.05 ); after LR nursing treatment, Ppeak, Pmean, DLC, PCO2, and PaO2/FiO2 of the patient were significantly greater than those before the LR, and the difference was statistically significant ( P < 0.05 ). In short, the WT algorithm not only enhanced the quality of ultrasound images but also shortened the running time and improved the processing efficiency. PEEP LR nursing treatment could effectively improve the vascular patency, cardiac ejection capacity, and DLC in patients with ARDS, thereby increasing the airway pressure and maintaining the unobstructed expiration.


Microscopy ◽  
2020 ◽  
Vol 69 (1) ◽  
pp. 31-36
Author(s):  
Ji-Youn Kim ◽  
Youngjin Lee

Abstract This study aimed to develop and evaluate an improved median filter (IMF) with an adaptive mask size for light microscope (LM) images. We acquired images of the mouse first molar using a LM at 100× magnification. The images obtained using our proposed IMF were compared with those from a conventional median filter. Several parameters such as the contrast-to-noise ratio, coefficient of variation, no-reference assessments and peak signal-to-noise ratio were employed to evaluate the image quality quantitatively. The results demonstrated that the proposed IMF could effectively de-noise the LM images and preserve the image details, achieving a better performance than the conventional median filter.


2021 ◽  
Vol 16 (3) ◽  
pp. 24-27
Author(s):  
E. Obi ◽  
B.O. Sadiq ◽  
O.S . Zakariyya ◽  
A. Theresa

Multiple-input multiple-output (MIMO) systems are increasingly becoming popular due to their ability to multiply data rates without any expansion in the bandwidth. This is critical in this era of high-data rate applications but limited bandwidth. MIMO detectors play an important role in ensuring effective communication in such systems and as such the performance of the following are compared in this paper with respect to symbol error rate (SER) versus signal-to-noise ratio (SNR): maximum likelihood (ML), zero forcing (ZF), minimum mean square error (MMSE) and vertical Bell laboratories layered space time (VBLAST). Results showed that the ML has the best performance as it has the least Symbol Error Rate (SER) for all values of Signal to Noise Ratio (SNR) as it was 91.9% better than MMSE, 99.6% better than VBLAST and 99.8% better than ZF at 20db for a 2x2 antenna configuration., it can also be deduced that the performance increased with increase in number of antenna for all detectors except the V-BLAST detector.


2021 ◽  
Author(s):  
Ping Gong

This dissertation describes ultrasound algorithms developed for synthetic transmit aperture (STA) imaging during the transmission and the image reconstruction stages. Images generated using these algorithms demonstrate image quality enhancement both theoretically and experimentally. The advanced algorithms also improve the application of STA imaging. Due to the single element transmission pattern, the low signal-to-noise ratio is a major limitation for STA imaging. A delay-encoded transmission scheme (DE-STA) was designed in this dissertation to encode all the transmissions. The decoded RF signals were equivalent to the standard STA signals, but with a higher SNR. Improved image qualities were observed under DE-STA transmission in terms of lateral resolution (+28%), peak-signal-to-noise ratio (PSNR, +7 dB) and target contrast-to-noise ratio (CNR, +360%) compared to those acquired with the standard STA mode. The stability of DE-STA was analyzed and verified under various noise levels by the special distribution of the singular values of the encoding matrix through singular value decomposition (SVD) (i.e. all the singular values were the same except for the first one and the last one). A more efficient decoding process was also derived based on pseudo-inversion (PI) and the computation complexity was reduced by 2/3. Speckle and undesired sidelobe signals can reduce the lesion CNR and detectability in ultrasound images. Typically, the CNR can be increased by spatial compounding (SC) or frequency compounding (FC) during reconstruction. We proposed methods to implement a 2-dimentional (2-D) aperture domain filter in the SC/FC processes, referred to as filtered spatial compounding (FSC) and filtered frequency compounding (FFC), for synthetic transmit aperture (STA) imaging. Both techniques reduced the sidelobe interference and provided improved lesion CNR. Consequently, the lesion signal-to-noise ratio (lSNR) in FSC and FFC increased (up to +130%), compared to that in the standard delay-and-sum (DAS) method. This dissertation investigates all these proposed advanced ultrasound algorithms, with the end goal of implementing these methods in STA imaging to extend its application in clinic.


Author(s):  
A.V. Akhmametieva ◽  
A.A. Baraniuk

Copyright protection of digital content is a rather actual problem of humanity in the 21st century. Misuses of multimedia content is very common, and their number is growing with each passing day. One type of copyright protection is the embedding of digital watermark (DW) in the content. In this paper a new method of embedding digital watermark into image using discrete cosine transform, lifting wavelet transform (LWT) with maternal wavelet "Dobeshi-8" and singular coefficients decomposition is proposed. Embedding is performed into the first singular number of the low frequency wavelet transform region. As a digital watermark, we will use a grayscale image normalized to a range from zero to ten to provide a high peak signal-to-noise ratio (PSNR). The research analyzed the developed method: the method of embedding and detecting information was tested for its resistance to various types of attacks, namely: application of noise overlay (Gauss and pulse noise, "salt and pepper"), "unsharp" filter and median filter, and compression attack (with quality coefficients for a complete container from 60 to 100). As a result of the conducted testing, it was established that the method is quite resistant to all the attacks, except for the "unsharp" filtering (the resulting performance is not satisfactory). The method showed good results in peak signal-to-noise ratio - the average PSNR value is 50.5 dB, as well as high rates of similarity between the embedded DW and the extracted one - from 77% to 97.6% while saving the full container in a lossless format, and up to 53, 05 dB and 91.96% while saving the image in a lossless format (JPEG).


2016 ◽  
Vol 7 (2) ◽  
pp. 657
Author(s):  
Hanifah Rahmi Fajrin

Kanker payudara merupakan pembunuh nomor satu pada wanita di seluruh dunia. Sejauh ini, deteksi dari kanker payudara hanya menggunakan mata telanjang dan berdasarkan jam terbang (pengalaman) dari dokter dan radiologis. Terdapat beberapa kelemahan dalam menganalisis mammogram payudara guna mendeteksi keberadaan kanker payudara. Hal ini bisa diakibatkan oleh sel kanker yang tertutup oleh noise, kontras citra yang rendah dan faktor manusiawi lainnya seperti : kelelahan, mood, dan lainnya. Untuk meminimalisir hal tersebut dibutuhkan suatu metode yang dapat membantu dokter dalam menganalisis citra mammogram payudara. Pada penelitian ini, dilakukan suatu proses yang bertujuan untuk meningkatkan kualitas mammogram agar lebih memudahkan dokter dalam mendiagnosis kelainan pada payudara. Citra yang diolah merupakan citra mammogram yang tidak dipangkas dan tidak disegmentasi pada bagian Region of Interest (ROI), melainkan keseluruhan citra payudara setelah dihilangkan background yang berlebihan. Tahapan pada proses peningkatan kuliatas citra mammogram ini (pra pengolahan) terdiri dari : menghilangkan label atau artifak yang ditemukan pada mammogram, meng-crop citra pada bagian payudara saja (menghilangkan background), memperbaiki kontras citra dengan membandingkan beberapa metode yaitu: CLAHE, Non Subsampled Contourlet Transform (NSCT), Contras Stretching (CS) dan selanjutnya dilakukan smoothing dengan menggunakan filter median. Kinerja dari setiap metode dihitung dengan mencari nilai Mean Square Error (MSE) dan Peak Signal to Noise Ratio (PSNR) citra. Dari nilai MSE dan PSNR yang didapatkan, ditemukan nilai MSE dan PSNR terbaik pada metode NSCT dengan nilai 50.20878 db 31.75332 db. Kata kunci: CLAHE, NSCT, CS, median filter.


Sign in / Sign up

Export Citation Format

Share Document