Improvement of Thermomechanical Fatigue Life in Nitrogen Alloyed 316 Stainless Steel

2005 ◽  
Vol 475-479 ◽  
pp. 1429-1432 ◽  
Author(s):  
Dae Whan Kim ◽  
Chang Hee Han ◽  
Woo Seog Ryu

Fatigue tests of type 316 and 316LN stainless steel were conducted at RT and 600ı, 0.8~1.5% strain range for low cycle fatigue (LCF), 300~600ı, 0% strain range for thermal fatigue (TF) and 300~600ı, 2% strain range, in-phase or out-of-phase for thermomechanical fatigue (TMF). LCF, TF, and TMF lives were increased but saturation stresses were decreased with the addition of nitrogen. The higher temperature was the lower TF life at a same temperature change. The minimum temperature change for TF failure was more than 100ı. TMF life was higher at inphase condition than at out-of-phase condition. Fracture mode was transgranular for LCF and outof- phase of TMF and almost transgranular and small intergranular for TF and in-phase TMF.

Author(s):  
Yuichi Fukuta ◽  
Yuichiro Nomura ◽  
Seiji Asada

NUREG/CR-6909 of USA and JSME of Japan proposed new rules for evaluating environmental effects in fatigue analyses of reactors components. These rules were established from a lot of fatigue data with polished specimens under simple loading condition. The effects of surface finish or complex loading condition were reported in some papers, but these data were obtained with the simple shaped specimens. In order to evaluate the effects of surface finish and loading condition and to confirm the applicability of the proposed rules to actual components, Low Cycle Fatigue tests are performed in PWR environment with the specimens cut from 316 austenitic stainless steel welded piping. The pipes are machined to have three levels of surface finish condition and the load pattern simulating the thermal stress is applied to specimens. In this study, the effect of surface finish on fatigue life is included to be small for 316 austenitic stainless steel welded piping. Considering the insensitive region in the current evaluation rule, predicted accuracy is increased and possibility of improving the current rule is indicated.


2014 ◽  
Vol 598 ◽  
pp. 160-167 ◽  
Author(s):  
Stanisław Mroziński ◽  
Michał Piotrowski

In this paper there have been presented the results of low-cycle fatigue tests of steel P91 samples in the conditions of isothermal fixed amplitude loads as well as loads with a temperature change. Fixed amplitude isothermal loads were conducted on five levels of full strain and in two temperatures T1=20°C and T2=600°C. In the paper there has been found a significant influence of the sequence of temperature changes on the cyclic properties after the temperature change and on the fatigue life. The conducted experimental verification of the Palmgren-Miner hypothesis proved its influence on the temperature changes during the tests.


Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4070
Author(s):  
Andrea Karen Persons ◽  
John E. Ball ◽  
Charles Freeman ◽  
David M. Macias ◽  
Chartrisa LaShan Simpson ◽  
...  

Standards for the fatigue testing of wearable sensing technologies are lacking. The majority of published fatigue tests for wearable sensors are performed on proof-of-concept stretch sensors fabricated from a variety of materials. Due to their flexibility and stretchability, polymers are often used in the fabrication of wearable sensors. Other materials, including textiles, carbon nanotubes, graphene, and conductive metals or inks, may be used in conjunction with polymers to fabricate wearable sensors. Depending on the combination of the materials used, the fatigue behaviors of wearable sensors can vary. Additionally, fatigue testing methodologies for the sensors also vary, with most tests focusing only on the low-cycle fatigue (LCF) regime, and few sensors are cycled until failure or runout are achieved. Fatigue life predictions of wearable sensors are also lacking. These issues make direct comparisons of wearable sensors difficult. To facilitate direct comparisons of wearable sensors and to move proof-of-concept sensors from “bench to bedside,” fatigue testing standards should be established. Further, both high-cycle fatigue (HCF) and failure data are needed to determine the appropriateness in the use, modification, development, and validation of fatigue life prediction models and to further the understanding of how cracks initiate and propagate in wearable sensing technologies.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6741
Author(s):  
Grzegorz Junak ◽  
Anżelina Marek ◽  
Michał Paduchowicz

This paper presents the results of tests conducted on the HR6W (23Cr-45Ni-6W-Nb-Ti-B) alloy under low-cycle fatigue at room temperature and at 650 °C. Fatigue tests were carried out at constant values of the total strain ranges. The alloy under low-cycle fatigue showed cyclic strengthening both at room temperature and at 650 °C. The degree of HR6W strengthening described by coefficient n’ was higher at higher temperatures. At the same time, its fatigue life Nf at room temperature was, depending on the range of total strain adopted in the tests, several times higher than observed at 650 °C.


Author(s):  
Takamoto Itoh

This study discusses multiaxial low cycle fatigue life of notched specimen under proportional and non-proportional loadings at room temperature. Strain controlled multiaxial low cycle fatigue tests were carried out using smooth and circumferentially notched round-bar specimens of type 316 stainless steel. Four kinds of notched specimens were employed of which elastic stress concentration factors, Kt, are 1.5, 2.5, 4.2 and 6.0. The strain paths include proportional and non-proportional loadings. The former employed a push-pull straining or a reversed torsion straining. The latter was achieved by strain path where axial and shear strains has 90 degree phase difference but their amplitudes is the same based on von Mises’ criterion. The notch dependency of multiaxial low cycle fatigue life and the life estimation are discussed. The lives depend on both Kt and strain path. The strain parameter for the life estimation is also discussed with the non-proportional strain parameter proposed by the author with introducing Kt. The proposed parameter gives a satisfactory correlation with multiaxial low cycle fatigue life of notched specimen of type 316 stainless steel under proportional and non-proportional loadings.


2021 ◽  
Vol 1035 ◽  
pp. 292-296
Author(s):  
Zi Chao Peng ◽  
Jun Ying Sheng ◽  
Xu Qing Wang ◽  
Yue Tang

Low cycle fatigue (LCF) properties of a powder metallurgy(PM) nickel base superalloy FGH720Li were systematically studied in this work, including smooth LCF and notched LCF tested at various temperatures and different stress. The relationship between the fatigue life and applied stress was analyzed both for smooth fatigue and notch fatigue tests. The effects of loading frequency and stress ratio on LCF behavior were also studied. As an important influencing factor of the fatigue life in powder metallurgy superalloy, the effect of inclusions on LCF life was also investigated. The results showed that the fatigue properties of FGH720Li alloy was excellent, when tested at the temperature of 450°C and applied stress of 1230MPa, the fatigue life could exceed 5×104 cycles. When tested at 650°C and 1150MPa, the average fatigue life was still beyond 2×105 cycles.