scholarly journals Clinical Outcomes Following Revision Total Knee Arthroplasty: Minimum 2-Year Follow-up

2021 ◽  
Vol 13 ◽  
Author(s):  
Jonathan Quinn ◽  
Peter Jones ◽  
Ray Randle
2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Takashi Hoshino ◽  
Toshifumi Watanabe ◽  
Yusuke Nakagawa ◽  
Hiroki Katagiri ◽  
Nobutake Ozeki ◽  
...  

Abstract Purpose This study assessed the clinical outcomes of periprosthetic joint infection patients who underwent two-stage revision total knee arthroplasty with antibiotic-loaded cement spacers fabricated using a handmade silicone mold. Materials and methods This study included seven patients (average age 77 years, average follow-up time 54 months) who underwent surgery at our hospital between 2009 and 2013. Clinical outcomes including knee scores, function scores, knee range of motion, and walking ability at the final observation, period from the primary total knee arthroplasty to implant removal, period from implant removal to revision total knee arthroplasty, and follow-up period after revision total knee arthroplasty were investigated. Results At the final follow-up, the average knee range of motion was 99°, with no significant differences at each stage; average knee and function scores were 84 and 77, respectively. With cement spacers, five patients were able to walk with a t-cane. No recurrence of infection was observed. Conclusions The clinical outcomes of the current case series demonstrated good knee function with preserved walking ability, without any recurrence of periprosthetic joint infection. This study suggests that using a handmade silicone mold could be an effective option for periprosthetic joint infection after a total knee arthroplasty.


Author(s):  
Jung-Won Lim ◽  
Yong-Beom Park ◽  
Dong-Hoon Lee ◽  
Han-Jun Lee

AbstractThis study aimed to evaluate whether manipulation under anesthesia (MUA) affect clinical outcome including range of motion (ROM) and patient satisfaction after total knee arthroplasty (TKA). It is hypothesized that MUA improves clinical outcomes and patient satisfaction after primary TKA. This retrospective study analyzed 97 patients who underwent staged bilateral primary TKA. MUA of knee flexion more than 120 degrees was performed a week after index surgery just before operation of the opposite site. The first knees with MUA were classified as the MUA group and the second knees without MUA as the control group. ROM, Knee Society Knee Score, Knee Society Functional Score, Western Ontario and McMaster Universities (WOMAC) score, and patient satisfaction were assessed. Postoperative flexion was significantly greater in the MUA group during 6 months follow-up (6 weeks: 111.6 vs. 99.8 degrees, p < 0.001; 3 months: 115.9 vs. 110.2 degrees, p = 0.001; 6 months: 120.2 vs. 117.0 degrees, p = 0.019). Clinical outcomes also showed similar results with knee flexion during 2 years follow-up. Patient satisfaction was significantly high in the MUA group during 12 months (3 months: 80.2 vs. 71.5, p < 0.001; 6 months: 85.8 vs. 79.8, p < 0.001; 12 months: 86.1 vs. 83.9, p < 0.001; 24 months: 86.6 vs. 85.5, p = 0.013). MUA yielded improvement of clinical outcomes including ROM, and patient satisfaction, especially in the early period after TKA. MUA in the first knee could be taken into account to obtain early recovery and to improve patient satisfaction in staged bilateral TKA.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.


2019 ◽  
Vol 34 (12) ◽  
pp. 3018-3022 ◽  
Author(s):  
Hussein Abdelaziz ◽  
Rodrigo Jaramillo ◽  
Thorsten Gehrke ◽  
Malte Ohlmeier ◽  
Mustafa Citak

2019 ◽  
Vol 34 (10) ◽  
pp. 2439-2443 ◽  
Author(s):  
Kevin M. Denehy ◽  
Sarag Abhari ◽  
Viktor E. Krebs ◽  
Carlos A. Higuera-Rueda ◽  
Linsen T. Samuel ◽  
...  

2020 ◽  
Vol 33 (09) ◽  
pp. 862-865
Author(s):  
John M. Tarazi ◽  
Hytham S. Salem ◽  
Joseph O. Ehiorobo ◽  
Nipun Sodhi ◽  
Michael A. Mont ◽  
...  

Abstract Background Newer generation cementless total knee arthroplasty (TKA) designs have provided stronger osteointegration between the implant and bone. Despite excellent survivorship and outcomes with cemented TKAs, areas of concern within the bone–cement interface remain a concern and necessitate studies on alternative constructs. This study assesses: (1) implant survivorship; (2) clinical outcomes; and (3) complications with radiographic outcomes at a 5-year minimum follow-up of cementless highly porous titanium-coated baseplates in TKAs. Methods Part of this study has been reported. We retrospectively reviewed a prospectively collected database at a single high-volume institution between July 1, 2013 and June 30, 2014 for patients who underwent a primary TKA using cementless highly porous titanium-coated baseplate implants. Patients were evaluated clinically at postoperative follow-up visits at a minimum of 5 years. To calculate the survivorship, Kaplan–Meier analysis was performed to determine all-cause, aseptic, and septic implant survivorship at each final follow-up for all patients. Results A total of 228 TKAs were performed and followed for a minimum of 5 years (range, 5–6 years). As of the latest follow-up, one case of septic loosening of the patellar button and one case of patellar dislodgment secondary to physical manipulation were recorded and revised. Overall, the cohort displayed implant survivorship of 99.5% at 5-year minimum follow-up. Improvements were seen in both Knee Society pain and function scores and were 37 points (range, 17–60 points) and 28 points (range, 15–47 points), respectively. The mean improvement in flexion was 17.8 (range, –20 to 40 degrees) and mean improvement in extension was –5.5 (range, –30 to 5 degrees). Discussion Cementless TKAs serve as strong alternative choice to cemented TKAs. Although cemented fixation is commonly known as the gold standard, results of this study confirm the findings of previous investigations on the survivorship of cementless TKA implants. Therefore, patients who undergo primary TKA with a cementless tritanium baseplate can expect excellent clinical outcomes at a 5-year minimum follow-up.


Sign in / Sign up

Export Citation Format

Share Document