Evaluation of a skin stapler for belt-loop gastropexy in dogs

1999 ◽  
Vol 35 (5) ◽  
pp. 440-444 ◽  
Author(s):  
BR Coolman ◽  
S Manfra Marretta ◽  
GJ Pijanowski ◽  
SL Coolman

A new method for attachment of a belt-loop gastropexy using disposable, stainless steel skin staples was compared with a traditional hand-sewn belt-loop gastropexy technique in 24 fresh dog cadavers. Mean gastropexy times were 212 seconds for the stapled technique and 435 seconds for the hand-sewn technique. The stapled belt-loop gastropexy was significantly faster than the hand-sewn technique (P less than 0.001). There was no statistically significant difference in the mean maximum tensile strength between the two attachment methods. This study provides a basis for clinical evaluation of the stapled belt-loop gastropexy technique in dogs.

2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


2021 ◽  
Author(s):  
Rabia Adanur-Atmaca ◽  
Serpil Çokakoğlu ◽  
Fırat Öztürk

ABSTRACT Objectives To evaluate the effects of different lingual retainers on periodontal health and stability of mandibular anterior teeth at the 1-year follow-up. Materials and Methods One hundred thirty-two patients were randomly allocated to four groups using different lingual retainers: group 1, 0.016 × 0.022-in dead-soft wire; group 2, 0.0215-in 5-strand stainless steel wire; group 3, 0.014 × 0.014-in computer-aided design/computer-aided manufacturing nitinol retainer (Memotain); group 4, connected bonding pads. Plaque, gingival, and calculus indexes were used to evaluate periodontal health, and Little's irregularity index, intercanine width, and arch length measurements were performed to evaluate stability. All measurements were performed at each time point (debonding and 3, 6, 9, and 12 months). Results The mean value of the gingival index obtained in group 3 was lower than the mean value for all other groups. The mean value of the calculus index was the lowest in group 3, and there was a significant difference between group 3 and groups 1 and 2. No differences were found among the groups in terms of plaque index, intercanine width, and arch length. The least irregularity was obtained in groups 2 and 3. There were no significant differences between these groups and groups 1 and 4. Conclusions Gingival inflammation and calculus accumulation were the lowest in group 3 (Memotain). The irregularity for Memotain and stainless steel retainers was less than or the other groups. However, no clinically significant worsening of periodontal health or relapse were seen in any groups after 1 year.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Amanpreet Singh Natt ◽  
Amandeep Kaur Sekhon ◽  
Sudhir Munjal ◽  
Rohit Duggal ◽  
Anup Holla ◽  
...  

Aim. To compare and evaluate the static frictional resistance offered by the four different types of ligation methods in both dry and wet conditions and at different durations when immersed in artificial saliva.Material and Methods. Alastik Easy to Tie modules, Super Slick Mini Stix elastomeric modules, Power “O” modules, and 0.009″Stainless Steel ligatures were used to compare the static friction using maxillary canine and premolar Preadjusted Edgewise brackets with 0.022″× 0.028″slot and 0.019″× 0.025″stainless steel wires.Results. The mean frictional resistance for Alastik modules was the lowest and that of Stainless Steel ligatures was found to be highest among the four groups compared and the difference among the four groups was statistically significant (P<0.005). The mean static frictional resistance in all groups under dry conditions was lower than that under wet conditions. No statistical significant differences were found when the groups were compared at different time periods of immersion in artificial saliva.Conclusion. This study concludes that the Alastik modules showed the lowest mean static frictional forces compared to any other ligation method, though no significant difference was found for different time periods of immersion in the artificial saliva.


2020 ◽  
Vol 14 (1) ◽  
pp. 704-710
Author(s):  
Mojdeh Mehdizadeh ◽  
Mohammad Bagher Tavakoli ◽  
Farida Ghazanfari Moghaddam

Purpose: To assess the efficacy of metal sheets with different thicknesses on reducing the radiation behind the photostimulable phosphor plate (PSP) during intraoral periapical examinations. Materials and Methods: In this study, a phantom head was used to investigate the effect of using metal sheets of aluminum, stainless steel, and copper with three thicknesses of 0.5, 0.75 and 1mm on reducing the radiation behind PSP. Images were acquired at 66 kVp 8 mA, and 0.16 s using the long-cone paralleling technique. The images were saved and exported to DICOM format without any post-processing. Then, they were transferred to an image processing software (Mimics, Materialize, Leuven, Belgium), and their mean gray values (MGV) were determined. The acquired data were statically analyzed for accessing the significant difference in groups means using ANOVA, and the means of groups were compared using Tukey’s test procedure. Results: The MGV of the second PSP differed significantly from those PSPs slotted with various metals (p<0.001). The MGV for lead and stainless steel at 0.5 mm thickness was insignificant (p = 0.852), but differed significantly from other metals. The MGV for PSPs with 0.75 mm stainless steel and 1 mm copper slots were varied significantly from those of all other PSP and metals. The 1 mm copper group was significantly different from all other groups (p<0.001). Conclusion: Using the mean gray value of the PSP, the use of various metal sheets of different thicknesses could effectively reduce the radiation behind the PSPs during periapical radiographs.


2019 ◽  
Vol 26 (08) ◽  
pp. 1359-1364
Author(s):  
Sara Jamil ◽  
Rizwan Jouhar ◽  
Dinaz Gandhi ◽  
Tayyaba Tahira ◽  
Jamshed Shaikh

Endodontic Pain if occurs after few hours or days after the treatment indicates a poor pathosis and a bad prognosis in long term, due to this a newer generation of instruments for canal treatment has been introduced from Ni-Ti alloy which has even better ability to shape narrow and curved root canals, without causing aberration. To compare the mean postoperative pain score after manual SS (stainless steel) K-files and mechanical Ni-Ti rotary path files in patients with irreversible pulpitis. Study Design: Randomized controlled trial. Setting: Department of Operative Dentistry, Altamash Institute of Dental Medicine, Karachi. Period: 6 months from 01-10-2017 to 30-03-2018. Materials and Methods: Total 60 patients of irreversible pulpitis with moderate pain score ≥5 were included and divided equally in manual stainless-steel k-files and mechanical Ni-Ti rotary path files groups. Treatment was started with local anesthesia. Patients were recalled after 24 hours and the level of postoperative pain was examined. T-test was applied to compare the outcome in both groups. Stratification was done using t-test and P value ≤0.05 was significantly considered. Results: The mean pre-treatment VAS in group-A and group-B was 7.16±1.44 and 7.86±1.38 respectively. Mean post-treatment VAS in group-A and group-B was 2.33±1.02 and 1.10±0.66 respectively. A significant difference between the pre and post op pain was noted between the two groups, when compared after 24hours by using VAS. Conclusion: Mean post-operative pain score was significantly less with NiTi rotary path files as compare to manual stainless steel K-files.


2016 ◽  
Vol 17 (9) ◽  
pp. 734-739
Author(s):  
Mohammed E Sayed ◽  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Mohamed S Mohamed

ABSTRACT Aim The aim of this study was to evaluate the effect of intermixing brands of addition silicone impression materials on the dimensional accuracy of stone models using two-step putty-wash technique. Materials and methods Two common brands of addition silicone impression material (Express and Aquasil) were used in this study. A total of 40 impressions of a stainless steel model simulating a three-unit bridge were made, 10 impressions for each group. Accuracy was assessed by measuring two dimensions (inter-abutment and intra-abutment) on stone models obtained from impressions of the stainless steel model. Each sample was measured thrice and the mean value was calculated. The data were analyzed using analysis of variance (ANOVA) and Scheffe's post hoc test. Results The results indicated that each of the inter-abutment and intra-abutment dimensions of the stone models was significantly higher than those for the stainless steel model (p < 0.001). However, there was no statistically significant difference in each of the inter-abutment and intra-abutment dimensions of the stone models among the four tested groups (p < 0.05). Conclusion The results obtained were statistically analyzed and the values of the inter-abutment and intra-abutment dimensions were all within the clinically acceptable range. Clinical significance Intermixing brands of additional silicone impression materials evaluated in this study did not affect the dimensional accuracy of obtained stone casts. This will help to minimize the wastage of materials due to lack of either light or putty consistency of the same brand of additional silicone impression material. How to cite this article Sayed ME, Al-Makramani BMA, Al-Sanabani FA, Mohamed MS. Effect of Intermixing Brands on the Dimensional Accuracy of Master Cast using Putty-wash Impression Technique. J Contemp Dent Pract 2016;17(9):734-739.


2013 ◽  
Vol 749 ◽  
pp. 173-179 ◽  
Author(s):  
Dan Hu ◽  
Shu Lin Li ◽  
Sheng Lu

In this paper, the effects of different TIG welding parameters on corrosion resistance of 321austenitic stainless steel welding joint were studied. Intergranular corrosion, stress-strain curves of SSRT and the fracture surface of the welding joint were investigated by means of intergranular corrosion test, SCC test and SEM. The results showed that the intergranular corrosion cracks did not occur for all joints welded in the range of TIG welding current of 130A~190A. In pure water at room temperature, strain rate at the range of 1×10-5 s-1~1×10-6 s-1 had little effect on the maximum tensile strength of the material under the same welding conditions and the time of joint fracture increased as the strain rate decreased. At strain rate of 1×10-6 s-1, the maximum tensile strength of the joint welded in the current of 130A and 150A decreased significantly in the dyeing assistant and presented stress corrosion sensitivity. Joints welded in the current of 170A and 190A, showed excellent resistance to stress corrosion. Through the analysis of the fracture surface of joints, the joint welded in current of 130A presented a tendency to brittle fracture, while the joints in the current of 170 A and190 A were characterized with ductile fracture.


2020 ◽  
Vol 45 (10) ◽  
pp. 1051-1054
Author(s):  
Abby Choke ◽  
Wong Yoke Rung ◽  
Duncan A. McGrouther ◽  
Hamid Rahmatullah Bin Abd Razak

We tested the tensile strength of the proximal juncture of tendon grafts with Pulvertaft tendon repairs in 18 cadaveric digital flexor tendons. These tendons were divided into three groups of six: single, two, or three weaves. Each of the interlacing weaves was secured with eight anchoring sutures. The specimens were loaded in a biomechanical tester until failure. The ultimate tensile strength did not show any significant differences across all three groups with statistical power of 0.77. The mean tendon elongation before repair failure showed significant difference at 10 mm (standard deviation (SD) 2), 16 mm (SD 3), and 15 mm (SD 3), respectively. All specimens failed by intra-tendinous pull-out of the weaves. We conclude that the two-weave Pulvertaft construct demonstrated comparable tensile strength to three weaves and tendon elongation was similar when two or three weaves were used.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Hooman Khorshidi ◽  
Saeed Raoofi ◽  
Rafat Bagheri ◽  
Hodasadat Banihashemi

Objectives. The mechanical properties of membranes are important factors in the success of treatment and clinical handling. The goal of this study was to compare the mechanical properties of early leukocyte- and platelet-rich fibrin (L-PRF) versus PRGF/Endoret membrane.Materials and Methods.In this experimental study, membranes were obtained from 10 healthy male volunteers. After obtaining 20 cc venous blood from each volunteer, 10 cc was used to prepare early L-PRF (group 1) and the rest was used to get a membrane by PRGF-Endoret system (group 2). Tensile loads were applied to specimens using universal testing machine. Tensile strength, stiffness, and toughness of the two groups of membranes were calculated and compared by pairedt-test.Results. The mean tensile strength and toughness were higher in group 1 with a significant difference (P<0.05). The mean stiffness in group 1 was also higher but not statistically significant (P>0.05).Conclusions.The results showed that early L-PRF membranes had stronger mechanical properties than membranes produced by PRGF-Endoret system. Early L-PRF membranes might have easier clinical handling and could be a more proper scaffold in periodontal regenerative procedures. The real results of the current L-PRF should be in fact much higher than what is reported here.


Sign in / Sign up

Export Citation Format

Share Document