scholarly journals Rancang Bangun Alat Penyimpanan ASI Dilengkapi Indikator Kadaluarsa Berbasis Arduino Uno

Lontara ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 133-138
Author(s):  
Risnawaty Alyah ◽  
St. Fatimang Fatimang

Breast milk storage is a tool used to store breast milk by cooling it using a certain temperature. Its function is to maintain the durability of breast milk so that the content in breast milk remains stable. Breast milk heater is a device that is used to warm breast milk by heating it to the temperature of the human body in general. Its function is to warm breast milk when it is cooled. Breast milk storage has a storage time of 24 hours with a temperature of 15°C, while the heating process uses a temperature of 37°C according to the temperature of the human body in general. In this research, the module uses the LM35 sensor as a hot room temperature sensor and a cold room temperature sensor. The temperature measurement detected by the LM35 is measured using a thermometer. The temperature data was taken 6 times. Based on the results of the analysis of measurements on breast milk storage at a temperature of 15°C, it has a standard deviation of 0.148, an error of 1.33% and an uncertainty of 0.013. And the results of the measurement analysis on heating breast milk with a temperature of 37°C have a standard deviation of 0.034, an error of -0.27% and an uncertainty of 0.06.

Author(s):  
Ari Ramadhani

Abstract - Automatic system have grown widespread across all sector so do water heater. Traditionally, heating water is done by utilizing fire as heat source. As the growing of technology, the heating process could be done by manipulating electrical energy by convert it to heat. Electrical energy is flown to a metal rod that contact directly with the water which increase the water temperature. On some case, appropiate water temperature is needed. Altough, a thermometer is needed to read the actual temperature as a feedback value for the system and a system that can control the electricity current flow through the heater that the heat produced is linear to the current flow. With implementing microcontroller as a process node for generating PWM signal, this problem can be solved. Also, Labview is needed as an interface for monitoring and bursting an output which have been processed by Proportional, Integral, and Devivative (PID) controller to producing accurate and stable heat. Based on the results of testing, the system is able to provide a rapid response to any changes that occur, both changes in set-point and changes in water temperature (actual value). Another test is done by comparing the temperature value detected by the temperature sensor in this device with an external digital thermometer placed in the same place, and from some of the tests the temperature value detected by the temperature sensor in this device has a difference of ± 0.19 ℃ with a digital thermometer. Keyword : Water Heater, Thermometer, Microcontroller, LabView, PID.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1700
Author(s):  
Anca Mihaela Vasile (Dragan) ◽  
Alina Negut ◽  
Adrian Tache ◽  
Gheorghe Brezeanu

An EEPROM (electrically erasable programmable read-only memory) reprogrammable fuse for trimming a digital temperature sensor is designed in a 0.18-µm CMOS EEPROM. The fuse uses EEPROM memory cells, which allow multiple programming cycles by modifying the stored data on the digital trim codes applied to the thermal sensor. By reprogramming the fuse, the temperature sensor can be adjusted with an increased trim variation in order to achieve higher accuracy. Experimental results for the trimmed digital sensor showed a +1.5/−1.0 ℃ inaccuracy in the temperature range of −20 to 125 ℃ for 25 trimmed DTS samples at 1.8 V by one-point calibration. Furthermore, an average mean of 0.40 ℃ and a standard deviation of 0.70 ℃ temperature error were obtained in the same temperature range for power supply voltages from 1.7 to 1.9 V. Thus, the digital sensor exhibits similar performances for the entire power supply range of 1.7 to 3.6 V.


RSC Advances ◽  
2021 ◽  
Vol 11 (41) ◽  
pp. 25731-25737
Author(s):  
Maria Cristina Righetti ◽  
Maria Laura Di Lorenzo ◽  
Patrizia Cinelli ◽  
Massimo Gazzano

At room temperature and at the human body temperature, all the amorphous fraction is mobile in poly(butylene succinate).


1977 ◽  
Vol 4 (2) ◽  
pp. 153-160 ◽  
Author(s):  
T. O'D. Hanley ◽  
B. Michel

Ice formation under controlled conditions was studied in a cold room using a cylindrical steel tank 120 cm in diameter and 76 cm deep. Paddles turned by a variable speed motor moved the water about the axis of the tank. Twenty-one thermistors were used to record temperatures above and below the surface of the water. Ice was allowed to form with the cold room temperature held at −2 °C, −5 °C, −10 °C, and −20 °C and with water speeds (measured 4 cm from the tank wall) from 0 to 73 cm/s.At zero water speed ice formed first as needles randomly oriented over the surface. With flowing water, border ice width increased linearly with time, but independently of water speed. The rate of increase of the border width w fits the equation dw/dt = (4/9)|Ta|0.68 where Ta is the Celsius air temperature.Frazil was never observed at water speeds less than 24 cm/s, but was always formed at this or greater speeds, regardless of cold room temperature. The volume of slush accumulated was greater at greater water speeds and at colder air temperatures. Observed slush volumes are compared with semiempirical values of the ice mass obtained from theoretical equations. The data suggest that growth of ice crystals began when the water was supercooled by approximately 0.02 °C.


2016 ◽  
Vol 850 ◽  
pp. 191-196 ◽  
Author(s):  
Wei Wang ◽  
Cun Lei Zou ◽  
Ren Geng Li ◽  
Wen Wen ◽  
Hui Jun Kang ◽  
...  

In situ synchrotron X-ray diffraction was used to study a deformed Cu-0.88 Fe-0.24 P alloy during heating process. The measurements were performed at room temperature and also at high temperatures up to 893 K in order to determine the recovery, ageing and recrystallization process. With the increase of temperature, the angles of copper matrix peaks moved left and the FWHM (full width at half maximum) decreased slightly. Fe3P precipitates were first detected at 533 K, reached the maximum at 673 K, and re-dissolved into matrix at 853 K. A dramatic decrease in FWHM was observed accompanied by the precipitation of Fe3P phases, indicating the reduction of lattice distortion of copper matrix.


2017 ◽  
Vol 41 (20) ◽  
pp. 11955-11961 ◽  
Author(s):  
Haoyuan Wang ◽  
Xia Kong ◽  
Shuai Zhao ◽  
Junshi Wu ◽  
Xiyou Li ◽  
...  

High-sensitive, quick-response room-temperature sensor to NO2 and NH3 is developed, based on QLS film of a new amphiphilic tris(phthalocyaninato) europium.


1948 ◽  
Vol 35 (1) ◽  
pp. 39-48 ◽  
Author(s):  
E. D. Smith ◽  
B. H. Ershoff ◽  
R. J. Winzler ◽  
H. J. Deuel

2017 ◽  
Vol 39 (1) ◽  
pp. 83 ◽  
Author(s):  
Andressa Strenske ◽  
Edmar Soares de Vasconcelos ◽  
Vanessa Aline Egewarth ◽  
Neusa Francisca Michelon Herzog ◽  
Marlene De Matos Malavasi

In this experiment, we assessed the germination and vigor of quinoa seeds packed in paper bags and stored at room temperature for 36, 85, 119, 146, 177 and 270 days. The seeds were harvested under experimental conditions in Marechal Candido Rondon, Paraná, during the 2012/13 growing seasons. Four replicates of 100 seeds each were established for each storage time, and the seeds were evaluated, on paper, based on the BOD under the following experimental temperature conditions: alternating temperatures of 20 and 30°C and a constant temperature of 25°C. The seeds from both treatments were subject to seven-hour photoperiods and 25°C under continuous darkness. The germinated seeds were counted daily for eight days after sowing, and we evaluated the percentages of normal and abnormal seedlings and the germination index. The experimental design was completely randomized using a split-plot design. Increasing the storage time decreased the percentage of germinated seeds and seed vigor due to the increased number of abnormal seedlings. Over the 430-day study period, quinoa seed germination completely declined under the experimental conditions. The final number of germinating seeds should be evaluated 7 days after the beginning of the germination test. 


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
T. Nowozin ◽  
D. Bimberg ◽  
K. Daqrouq ◽  
M. N. Ajour ◽  
M. Awedh

The present paper investigates the current status of the storage times in self-organized QDs, surveying a variety of heterostructures advantageous for strong electron and/or hole confinement. Experimental data for the electronic properties, such as localization energies and capture cross-sections, are listed. Based on the theory of thermal emission of carriers from QDs, we extrapolate the values for materials that would increase the storage time at room temperature to more than millions of years. For electron storage, GaSb/AlSb, GaN/AlN, and InAs/AlSb are proposed. For hole storage, GaSb/Al0.9Ga0.1As, GaSb/GaP, and GaSb/AlP are promising candidates.


1995 ◽  
Vol 10 (3) ◽  
pp. 173-177 ◽  
Author(s):  
P. Ballirano ◽  
A. Maras ◽  
R. Caminiti ◽  
C. Sadun

New powder X-ray data for cancrinite [ideally Na8Si6Al6O24 (CO3)2·2 H2O] are reported along with in-situ real-time thermal processes recorded using energy dispersive X-ray diffractometry (EDXD). A completely anhydrous phase is obtained after heating the sample up to 600 °C and quickly cooling it to room temperature, as shown by means of both Rietveld analysis and IR spectroscopy. The anhydrous phase does not show any tendency to re-acquire molecular water. During the heating process, at around 450 °C, a peak splitting is observed, possibly due to a reversible phase transition.


Sign in / Sign up

Export Citation Format

Share Document