scholarly journals Experience of mAndibular reconstruction using a metal plate with condylar head for 4 hemimandibulectomy patients and estimation its post operative function.

1989 ◽  
Vol 35 (7) ◽  
pp. 1909-1916
Author(s):  
Kuniko SUZUKI ◽  
Fumiaki SAITOU ◽  
Masashi SUGISAKI ◽  
Haruyasu TANABE
2019 ◽  
Vol 77 (6) ◽  
pp. 1286-1292 ◽  
Author(s):  
Wei Wang ◽  
Xiao-feng Shan ◽  
Jie Liang ◽  
Shang Xie ◽  
Jie Zhang ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Jie Chen ◽  
Ruipu Zhang ◽  
Ye Liang ◽  
Yujie Ma ◽  
Saiwen Song ◽  
...  

BackgroundComputer-assisted and template-guided mandibular reconstruction provides higher accuracy and less variation than conventional freehand surgeries. The combined osteotomy and reconstruction pre-shaped plate position (CORPPP) technique is a reliable choice for mandibular reconstruction. This study aimed to evaluate the accuracy of CORPPP-guided fibular flap mandibular reconstruction and analyze the possible causes of the deviations.Patients and MethodsFrom June 2015 to December 2016, 28 patients underwent fibular flap mandibular reconstruction. Virtual planning and personalized CORPPP-guided templates were applied in 15 patients while 13 patients received conventional freehand surgeries. Deviations during mandibulectomy and fibular osteotomy, and overall and triaxial deviation of the corresponding mandibular anatomical landmarks were measured by superimposing the pre- and postoperative virtual models.ResultsThe deviation of the resection line and resection angle was 1.23 ± 0.98 mm and 4.11° ± 2.60°. The actual length of fibula segments was longer than the designed length in 7 cases (mean: 0.35 ± 0.32 mm) and shorter in 22 cases (mean: 1.53 ± 1.19 mm). In patients without ramus reconstruction, deviations of the ipsilateral condylar head point (Co.), gonion point (Go.), and coracoid process point (Cor.) were 6.71 ± 3.42 mm, 5.38 ± 1.71 mm, and 11.05 ± 3.24 mm in the freehand group and 1.73 ± 1.13 mm, 1.86 ± 0.96 mm, and 2.54 ± 0.50 mm in the CORPPP group, respectively, with significant statistical differences (p < 0.05). In patients with ramus reconstruction, deviations of ipsilateral Co. and Go. were 9.79 ± 4.74 mm vs. 3.57 ± 1.62 mm (p < 0.05), and 15.17 ± 6.53 mm vs. 4.36 ± 1.68 mm (p < 0.05) in the freehand group and CORPPP group, respectively.ConclusionMandibular reconstructions employing virtual planning and personalized CORPPP-guided templates show significantly higher predictability, convenience, and accuracy of mandibular reconstruction compared with conventional freehand surgeries. However, more clinical cases were required for further dimensional deviation analysis. The application and exploration of clinical practice would also continuously improve the design of templates.


1986 ◽  
Vol 56 (9) ◽  
pp. 701-706 ◽  
Author(s):  
Patrick J. Gullane ◽  
Thomas E. Havas ◽  
Howard H. Holmes

2020 ◽  
Vol 8 (9) ◽  
pp. e3088
Author(s):  
Ryo Yamochi ◽  
Toshiaki Numajiri ◽  
Hiroko Nakamura ◽  
Daiki Morita ◽  
Yoshihiro Sowa

1991 ◽  
Vol 24 (6) ◽  
pp. 1391-1418 ◽  
Author(s):  
Daniel B. Kuriloff ◽  
Michael J. Sullivan

1994 ◽  
Vol 21 (1) ◽  
pp. 37-44 ◽  
Author(s):  
Saleh M. Shenaq ◽  
Michael J.A. Klebuc

2001 ◽  
Vol 40 (02) ◽  
pp. 51-58 ◽  
Author(s):  
H. Schliephake ◽  
van den Hoff ◽  
W. H. Knapp ◽  
G. Berding

Summary Aim: Determination of the range of regional blood flow and fluoride influx during normal incorporation of revascularized fibula grafts used for mandibular reconstruction. Evaluation, if healing complications are preceded by typical deviations of these parameters from the normal range. Assessment of the potential influence of using “scaled population-derived” instead of “individually measured” input functions in quantitative analysis. Methods: Dynamic F-l 8-PET images and arterialized venous blood samples were obtained in 11 patients early and late after surgery. Based on kinetic modeling regional blood flow (K1) and fluoride influx (Kmlf) were determined. Results: In uncomplicated cases, early postoperative graft K1 - but not Kmlf -exceeded that of vertebrae as reference region. Kmn values obtained in graft necrosis (n = 2) were below the ranges of values observed in uncomplicated healing (0.01 13-0.0745 ml/min/ml) as well as that of the reference region (0.0154-0.0748). Knf values in mobile non-union were in the lower range - and those in rigid non-union in the upper range of values obtained in stable union (0.021 1-0.0694). If scaled population-derived instead of measured input functions were used for quantification, mean deviations of 23 ± 17% in K1 and 12 ± 16% in Kmlf were observed. Conclusions: Normal healing of predominantly cortical bone transplants is characterized by relatively low osteoblastic activity together with increased perfusion. It may be anticipated that transplant necrosis can be identified by showing markedly reduced F− influx. In case that measured input functions are not available, quantification with scaled population-derived input functions is appropriate if expected differences in quantitative parameters exceed 70%.


2013 ◽  
Vol 51 (7) ◽  
pp. 535-545 ◽  
Author(s):  
Kwang-Seok Lee ◽  
Su-Eun Lee ◽  
Jung Su Kim ◽  
Min Jung Kim ◽  
Dong Hyun Bae ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document