ventricular assist devices
Recently Published Documents


TOTAL DOCUMENTS

3812
(FIVE YEARS 1045)

H-INDEX

80
(FIVE YEARS 9)

Author(s):  
Jonathan B. Edelson ◽  
Jonathan J. Edwards ◽  
Hannah Katcoff ◽  
Antara Mondal ◽  
Feiyan Chen ◽  
...  

Background The past decade has seen tremendous growth in patients with ambulatory ventricular assist devices. We sought to identify patients that present to the emergency department (ED) at the highest risk of death. Methods and Results This retrospective analysis of ED encounters from the Nationwide Emergency Department Sample includes 2010 to 2017. Using a random sampling of patient encounters, 80% were assigned to development and 20% to validation cohorts. A risk model was derived from independent predictors of mortality. Each patient encounter was assigned to 1 of 3 groups based on risk score. A total of 44 042 ED ventricular assist device patient encounters were included. The majority of patients were male (73.6%), <65 years old (60.1%), and 29% presented with bleeding, stroke, or device complication. Independent predictors of mortality during the ED visit or subsequent admission included age ≥65 years (odds ratio [OR], 1.8; 95% CI, 1.3–4.6), primary diagnoses (stroke [OR, 19.4; 95% CI, 13.1–28.8], device complication [OR, 10.1; 95% CI, 6.5–16.7], cardiac [OR, 4.0; 95% CI, 2.7–6.1], infection [OR, 5.8; 95% CI, 3.5–8.9]), and blood transfusion (OR, 2.6; 95% CI, 1.8–4.0), whereas history of hypertension was protective (OR, 0.69; 95% CI, 0.5–0.9). The risk score predicted mortality areas under the curve of 0.78 and 0.71 for development and validation. Encounters in the highest risk score strata had a 16‐fold higher mortality compared with the lowest risk group (15.8% versus 1.0%). Conclusions We present a novel risk score and its validation for predicting mortality of patients with ED ventricular assist devices, a high‐risk, and growing, population.


2022 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Alexandra N. Romanova ◽  
Alexander A. Pugovkin ◽  
Maxim V. Denisov ◽  
Ivan A. Ephimov ◽  
Dmitry V. Gusev ◽  
...  

Background: Currently, left ventricular assist devices (LVADs) are a successful surgical treatment for patients with end-stage heart failure on the waiting list or with contraindicated heart transplantation. In Russia, Sputnik 1 LVAD was also successfully introduced into clinical practice as a bridge-to-transplant and a destination therapy device. Development of Sputnik 2 LVAD was aimed at miniaturization to reduce invasiveness, optimize hemocompatibility, and improve versatility for patients of various sizes. Methods: We compared hemolysis level in flow path of the Sputnik LVADs and investigated design aspects influencing other types of blood damage, using predictions of computational fluid dynamics (CFD) and experimental assessment. The investigated operating point was a flow rate of 5 L/min and a pressure head of 100 mm Hg at an impeller rotational speed of 9100 min−1. Results: Mean hemolysis indices predicted with CFD were 0.0090% in the Sputnik 1 and 0.0023% in the Sputnik 2. Averaged values of normalized index of hemolysis obtained experimentally for the Sputnik 1 and the Sputnik 2 were 0.011 ± 0.003 g/100 L and 0.004 ± 0.002 g/100 L, respectively. Conclusions: Obtained results indicate obvious improvements in hemocompatibility and sufficiently satisfy the determined miniaturization aim for the Sputnik 2 LVAD development.


2022 ◽  
Vol 9 (1) ◽  
pp. 18
Author(s):  
Johannes Weichsel ◽  
Benito Baldauf ◽  
Hendrik Bonnemeier ◽  
Ernest W. Lau ◽  
Sven Dittrich ◽  
...  

Ventricular assist devices (VADs) are used to provide mechanical circulatory support to patients with end-stage heart failure. The driveline connecting the external power source to the pump(s) of the intra-corporal VAD breaches the protective skin barrier and provides a track for microbes to invade the interior of the patient’s body. Driveline infection constitutes a major and potentially fatal vulnerability of VAD therapy. Driveline infection cannot traditionally be salvaged and requires the extraction of the entire VAD system. We report here the successful eradication of a VAD driveline infection with a taurolidine-containing antimicrobial solution used for preventing the infection of cardiac implantable electronic devices. If replicated in more cases, the novel treatment concept described here may provide a valuable alternative management strategy of salvage rather than explantation for VAD driveline infection.


Healthcare ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 114
Author(s):  
Dusko Terzic ◽  
Svetozar Putnik ◽  
Emilija Nestorovic ◽  
Vladimir Jovicic ◽  
Dejan Lazovic ◽  
...  

The aim of this study was to examine the incidence and significance of right heart failure (RHF) in the early and late phase of left ventricular assist device (LVAD) implantation with the identification of predictive factors for the development of RHF. This was a prospective observational analytical cohort study. The study included 92 patients who underwent LVAD implantation and for whom all necessary clinical data from the follow-up period were available, as well as unambiguous conclusions by the heart team regarding pathologies, adverse events, and complications. Of the total number of patients, 43.5% died. The median overall survival of patients after LVAD implantation was 22 months. In the entire study population, survival rates were 88.04% at one month, 80.43% at six months, 70.65% at one year, and 61.96% at two years. Preoperative RHF was present in 24 patients, 12 of whom died and 12 survived LVAD implantation. Only two survivors developed early RHF (ERHF) and two late RHF (LRHF). The most significant predictors of ERHF development are brain natriuretic peptide (BNP), pre-surgery RHF, FAC < 20%, prior renal insufficiency, and total duration of ICU stay (HR: 1.002, 0.901, 0.858, 23.554, and 1.005, respectively). RHF following LVAD implantation is an unwanted complication with a negative impact on treatment outcome. The increased risk of fatal outcome in patients with ERHF and LRHF after LVAD implantation results in a need to identify patients at risk of RHF, in order to administer the available preventive and therapeutic methods.


2022 ◽  
Author(s):  
Florim Cuculi ◽  
Philipp Burkart ◽  
Giacomo Cioffi ◽  
Federico Moccetti ◽  
Mehdi Madanchi ◽  
...  

Abstract Objective: To compare the safety and efficacy of manual compression versus use of the MANTA® closure device for access management after Impella® removal on the intensive care unit (ICU).Background: The number of patients treated with percutaneous left ventricular assist devices (pLVAD), namely Impella® and ECMO, for complex cardiac procedures or shock, is growing. However, removal of pLVAD and large bore arteriotomy closure among such patients on the ICU remains challenging, since it is associated with a high risk for bleeding and vascular complications. Methods: Patients included in a prospective registry between 2017 and 2020 were analyzed. Bleeding and vascular access site complications were assessed and adjudicated according to VARC-2 criteria. Results: We analyzed a cohort of 87 consecutive patients, who underwent access closure after Impella® removal on ICU by using either the MANTA® device or manual compression. The cohort´s mean age was 66.1±10.7 years and 76 patients (87%) were recovering from CS. Mean support time was 40 hours (Interquartile range 24–69 hours). MANTA® was used in 31 patients (35.6%) and manual compression was applied in 56 patients (64.4%). Overall access related bleedings were significantly lower in the MANTA® group (6.5% versus 39.3%(odds ratio (OR) 0.10, 95% CI 0.01–0.50; p=0.001), and there was no significant difference in vascular complications between the two groups(p=0.55).Conclusions: Our data suggests that the application of the MANTA® device directly on the ICU is safe. In addition, it seems to reduce access related bleeding without increasing the risk of vascular complications.


Sign in / Sign up

Export Citation Format

Share Document