Metals ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 108
Author(s):  
Alfonso Ruiz-Pineda ◽  
Alicia Aguilar-Corona ◽  
Constantin Alberto Hernández-Bocanegra ◽  
José Ángel Ramos-Banderas ◽  
Gildardo Solorio-Díaz ◽  
...  

In this work, the fluid dynamics and heat transfer of two hydraulic nozzles used in the secondary cooling of the conventional slab continuous casting machine were analyzed. Impingement density maps, the jet opening angle and heat flux associated with different operating conditions (impingement distance, pressure) were experimentally determined. The opening angle and impingement density footprint were found to vary considerably in shape and magnitude with varying operating pressure and distances. Finally, it was found that when short operating distances are used, a greater heat extraction gradient occurs in the major axis of the impingement footprint, which promotes edge-cracks in the slab in plant.


2022 ◽  
Vol 0 (0) ◽  
Author(s):  
Ganesh N. Patil ◽  
Nirmala Gnanasundaram

Abstract Ethyl acetate (EtAc) reactive distillation (RD) configurations often use atmospheric pressure, and this operating pressure can be reduced further to conserve energy based on the condenser cooling water temperature. Using the Aspen Plus simulator, two proposed configurations, RD column with stripper and pressure swing reactive distillation (PSRD), were simulated at lower operating pressure. The impact of RD column operating pressure on total energy usage and total annual cost (TAC) was studied. All design parameters were optimized using sequential iterative optimization procedures and sensitivity analysis to minimize the energy cost while maintaining the required product purity at 99.99%. The simulation results showed that the RD column with a stripper is better than PSRD with a saving of 23.17% in TAC and 31.53% in the specific cost of EtAc per kg. Compared to literature results, the proposed configurations have lower reboiler duty requirements and lower cost per kg of EtAc.


2022 ◽  
pp. 28-30
Author(s):  

Consensus water chemistry controls for the six types of steam generator systems are presented in Tables 1 through 7. The tabulated information is categorized according to operating pressure ranges because this is the prime factor that dictates the type of internal water chemistry employed, the normal cycles of feedwater concentration, the silica volatility, and the carryover tendency. The difference between steam and water densities decreases with increasing pressure and temperature; therefore, separating the steam/water phases completely in the boiler drum becomes increasingly difficult to achieve. Since the tendency to carryover is greater at higher operating pressures, it is necessary to maintain lower boiler water contaminant concentrations to meet the same steam purity target.


2021 ◽  
Vol 25 (6) ◽  
pp. 66-70
Author(s):  
Sung-Soo Park ◽  
Sang-Chan Park ◽  
Ji-Hoon Yoon ◽  
Sung-Hoon Seol ◽  
Chang-Hyo Son ◽  
...  

Fermentation ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 15
Author(s):  
Alessio Siciliano ◽  
Carlo Limonti ◽  
Giulia Maria Curcio

Anaerobic digestion (AD) represents an advantageous solution for the treatment and valorization of organic waste and wastewater. To be suitable for energy purposes, biogas generated in AD must be subjected to proper upgrading treatments aimed at the removal of carbon dioxide and other undesirable gases. Pressurized anaerobic digestion (PDA) has gained increasing interest in recent years, as it allows the generation of a high-quality biogas with a low CO2 content. However, high pressures can cause some negative impacts on the AD process, which could be accentuated by feedstock characteristics. Until now, few studies have focused on the application of PAD to the treatment of real waste. The present work investigated, for the first time, the performance of the pressurized anaerobic digestion of raw compost leachate. The study was conducted in a lab-scale pressurized CSTR reactor, working in semi-continuous mode. Operating pressures from the atmospheric value to 4 bar were tested at organic loading rate (OLR) values of 20 and 30 kgCOD/m3d. In response to the rise in operating pressure, for both OLR values tested, a decrease of CO2 content in biogas was observed, whereas the CH4 fraction increased to values around 75% at 4 bar. Despite this positive effect, the pressure growth caused a decline in COD removal from 88 to 62% in tests with OLR = 20 kgCOD/m3d. At OLR = 30 kgCOD/m3d, an overload condition was observed, which induced abatements of about 56%, regardless of the applied pressure. With both OLR values, biogas productions and specific methane yields decreased largely when the pressure was brought from atmospheric value to just 1 bar. The values went from 0.33 to 0.27 LCH4/gCODremoved at 20kgCOD/m3d, and from 0.27 to 0.18 LCH4/gCODremoved at 30 kgCOD/m3d. Therefore, as the pressure increased, although there was an enhanced biogas quality, the overall amount of methane was lowered. The pressured conditions did not cause substantial modification in the characteristics of digestates.


Water ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 44
Author(s):  
Ihab Shigidi ◽  
Ali E. Anqi ◽  
Abubakar Elkhaleefa ◽  
Azam Mohamed ◽  
Ismat H. Ali ◽  
...  

Reverse osmosis technique was applied in removing hexavalent chromium ions from artificial wastewater. Different operating conditions were studied to monitor the separation process using commercial Reverse Osmosis BW30XFR membrane. Different concentrations of hexavalent chromium; 5, 30, and 100 ppm were tested. Samples were subjected to incrementally increasing operating pressure; 10, 30, and 45 bar and flow rates; 2.2, 3.4, and 4.5 L/min under various temperatures; 25, 35, 45, and 55 °C. Collected permeate and concentrations were measured after each experiment using a UV spectrophotometer. Results obtained presented a higher rejection percentage at lower feed concentrations with a value up to 99.8% for 5 ppm in comparison to 94.3% for 30 ppm and 77.2% for 100 ppm concentration due to concentration polarization; however, it showed no effect of increasing operating flow rates. Moreover, the increase in feed temperature from 25 to 55 °C had positively increased permeate flux to more than 300 times. The permeate flux at 25 °C is recorded for all tested samples in the range of 30 to 158 kg/h·m2, this range has risen at 55 °C under the same conditions to the range of 70 to 226 kg/h·m2, indicating alteration within the membrane pore size due to temperature increase and high applied pressure concluding high sensitivity of polymeric membranes towards changing permeate flow rate with increasing temperatures.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8596
Author(s):  
Hyeok Kim ◽  
Geonhwi Kim ◽  
Jaeyeon Kim ◽  
Dasol Kim ◽  
Obeen Kwon ◽  
...  

Polymer electrolyte membrane fuel cells were analyzed to investigate changes in the structure of the flow field and operating conditions. The cell performance, which was controlled by adjusting the width of the cathodic channel, improved as the backpressure increases. With the anodic and cathodic flow channels mismatched, the maximum power densities at 3.0 bar for a narrow cathodic channel were 1115 and 1024 mW/cm2, and those for a wide cathodic channel were 959 and 868 mW/cm2, respectively. The diffusion characteristics were investigated using the non-dimensional numbers Re (Reynolds), Sc (Schmidt), and Sh (Sherwood) to confirm the improvement of mass transport. The narrower the channel or the higher the operating pressure, the larger Re was and the smaller Sc and Sh became. In particular, the wider the anodic channel, the larger the value of Sh.


Author(s):  
B. Krishna Kanth ◽  
C. Ramana ◽  
S. Joseph Reddy ◽  
L. Eadukondalu ◽  
B. Ravindra Reddy

The electrostatic induction mechanism, which superimposes charges on pesticide spray droplets, creates an impact on deposition and wraparound effect on leaf surfaces Smaller droplets have a higher capability to charge accumulation over the surface of the droplet as compared with larger droplets. This paper studied the effect of nozzle type (flat fan, hollow cone, and full cone nozzle), orifice area (1 and 1.5 mm2), and operating pressure (3-5kg cm-2) on spray droplet characteristics on soil bin. Water-sensitive papers were analysed by image analysis software to get the droplet characteristics.   The smallest droplets of a hollow cone, flat fan, and full cone were 130, 142, and 279.76 µm respectively produced at 5kg cm-2 and orifice opening 1 mm2.  With an increase of pressure droplet size and relative span was decreased for all selective nozzle. From the selected nozzles, the lowest relative span of 0.89 was found with a hollow cone nozzle at 5 kg cm-2 pressure and orifice size of 1 mm2. Among all the selected nozzles hollow cone nozzle produced the smallest droplet sizes and lowest relative span for all selected parameters.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8395
Author(s):  
Ulf Hummel ◽  
Peter Radgen ◽  
Sercan Ülker ◽  
Ralph Schelle

The compressed air electric ratio (CAER) describes the ratio of the real electric power demand to the nominal mechanical power of an air compressor. The CAER is an important indicator as the electric power demand of air compressors varies throughout its operation dependent on compressor technology, pressure ratio, and free air delivery. The nameplate power of the compressor drive motor is not sufficient for evaluating the electric power demand; therefore, the CAER plays an important role in assessing the electric operating power demand. In this paper, results from measurements of fixed speed and variable speed (VFD) compressors are presented with the analysis of key influencing factors of the CAER. The data show that the pressure ratio of operating pressure to the maximum design outlet pressure has the largest impact on the CAER. For VFD compressors, the CAER is represented as a linear function dependent on the respective load. Fixed and variable speed compressors’ CAERs are always dependent on the load condition. In idle condition, the CAER was measured to be 0.2. In full load condition with a pressure ratio of 0.6, the CAER averages at a value of 0.87, meaning a 90 kW compressor at 0.6 pressure ratio draws 78.3 kW electric power.


2021 ◽  
Author(s):  
Sujet Phodapol ◽  
Tachadol Suthisomboon ◽  
Pong Kosanunt ◽  
Ravipas Vongasemjit ◽  
Petch Janbanjong ◽  
...  

Abstract Passive and active hybrid pipeline inspection gauges (PIGs) have been used for in-pipe inspection. While a passive PIG cannot control its speed, the hybrid version can achieve this by using an integrated valve specifically designed and embedded in the PIG. This study proposes a generic new method for speed adaptation in PIGs (called MC-PIG) by introducing a generic, modular, controllable, external valve unit add-on for attaching to existing conventional (passive) PIGs with minimal change. The MC-PIG method is based on the principle of morphological computation with closed-loop control. It is achieved by regulating/computing the PIG's morphology (i.e., a modular rotary valve unit add-on) to control bypass flow. Adjustment of the valve angle can affect the flow rate passing through the PIG, resulting in speed regulation ability. We use numerical simulation with computational fluid dynamics (CFD) to investigate and analyze the speed of a simulated PIG with the valve unit adjusted by proportional-integral (PI) control under various in-pipe pressure conditions. Our simulation experiments are performed under different operating conditions in three pipe sizes (16″, 18″, and 22″ in diameter) to manifest the speed adaptation of the PIG with the modular valve unit add-on and PI control. Our results show that the PIG can effectively perform real-time adaptation (i.e., adjusting its valve angle) to maintain the desired speed. The valve design can be adjusted from 5 degrees (closed valve, resulting in high moving speed) to a maximum of 45 degrees (fully open valve, resulting in low moving speed). The speed of the PIG can be regulated from 0.59 m/s to 3.88 m/s in a 16″ pipe at 4.38 m/s (in-pipe fluid velocity), 2500 kPa (operating pressure), and 62 °C (operating temperature). Finally, the MC-PIG method is validated using a 3D-printed prototype in a 6″ pipe. Through the investigation, we observed that two factors influence speed adaptation; the pressure drop coefficient and friction of the PIG and pipeline. In conclusion, the results from the simulation and prototype show close characteristics with an acceptable error.