organ motion
Recently Published Documents


TOTAL DOCUMENTS

409
(FIVE YEARS 36)

H-INDEX

41
(FIVE YEARS 2)

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Raffaella Lucchini ◽  
Denis Panizza ◽  
Riccardo Ray Colciago ◽  
Veronica Vernier ◽  
Martina Camilla Daniotti ◽  
...  

Abstract Purpose/objectives To report preliminary data on treatment outcome and compliance to dose-intensified organ sparing SBRT for prostate cancer using a novel electromagnetic transmitter-based tracking system (RayPilot® System) to account for intra-fractional organ motion. Material/methods Thirteen patients with intermediate unfavorable (9) and selected high-risk (4) prostate cancer underwent dose-escalated SBRT in 4 or 5 fractions (BED1.5 = 279 Gy and 253 Gy, respectively). The VMAT treatment consisted in two 6FFF or 10FFF full arcs optimized to have the 95% isodose covering at least 95% of the PTV (2 mm isotropic expansion of the CTV). Whenever the real-time tracking registered a displacement that exceeded 2 mm during the setup and/or the beam delivery, the treatment was interrupted and the prostate motion was promptly corrected. The incidence of treatment-related genitourinary (GU) and gastrointestinal (GI) toxicity, patient QoL and PSA outcomes were computed from the start of treatment to the last follow-up date. Results All patients completed the treatment in the expected time (10.2 +/− 4.2 minutes) and their compliance to the procedure was excellent. No clinically significant acute Grade 2 or higher GI (rectal) and GU side effects were observed within 90 days from the treatment completion. The median IPSS increased from 8 at baseline to 12 one-month after treatment and settled to 6 at 3 months. EPIC-26 scores in the urinary domain decreased from a median baseline of 86 pre-treatment to 79 at one-month and returned to baseline at a later timepoint (median score of 85 at 3 months). EPIC-26 scores in the bowel domains did not show significant changes within 3 months following RT. The prostate was found within 1 mm from its initial position in 78% of the beam-on time, between 1 and 2 mm in 20%, and exceeded 2 mm only in 2%, after correction for motion which was performed in 45% of the fractions, either during setup or beam delivery. Conclusions Our preliminary findings show that dose intensified SBRT for unfavorable prostate tumors does not come at the cost of an increased toxicity, provided that a reliable technique for real time prostate monitoring is ensured. Fast FFF beams contributed to reduce intra-fractional motion. These observations need to be confirmed on a larger scale and a longer follow up.


2021 ◽  
Vol 161 ◽  
pp. S1673-S1674
Author(s):  
P. Marolt ◽  
R. Hudej ◽  
B. Šegedin ◽  
H.B. Zobec Logar ◽  
M. Kobav

2021 ◽  
Vol 161 ◽  
pp. S1263
Author(s):  
S. Ding ◽  
H. Liu ◽  
B. Wang ◽  
Y. Li ◽  
B. Liu ◽  
...  

2021 ◽  
Vol 161 ◽  
pp. S1284-S1285
Author(s):  
F. La Fauci ◽  
G. Marvaso ◽  
M. Augugliaro ◽  
S. Comi ◽  
M. Pepa ◽  
...  

2021 ◽  
Vol 161 ◽  
pp. S171-S173
Author(s):  
E.R. Gunwhy ◽  
Z. van Kesteren ◽  
M.J. Parkes ◽  
M.F. Stevens ◽  
J.G. van den Aardweg ◽  
...  

2021 ◽  
Vol 161 ◽  
pp. S1478-S1479
Author(s):  
B. Knäusl ◽  
F. Lebbink ◽  
P. Fossati ◽  
E. Engwall ◽  
T. Madar ◽  
...  
Keyword(s):  

2021 ◽  
Vol 161 ◽  
pp. S1275-S1276
Author(s):  
K. Busch ◽  
A.G. Andersen ◽  
J.B. Petersen ◽  
S.E. Petersen ◽  
H.S. Rønde ◽  
...  
Keyword(s):  

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Annarita Perillo ◽  
Valeria Landoni ◽  
Alessia Farneti ◽  
Giuseppe Sanguineti

Abstract Purpose The purpose of this study is to evaluate inter- and intra-fraction organ motion as well as to quantify clinical target volume (CTV) to planning target volume (PTV) margins to be adopted in the stereotactic treatment of early stage glottic cancer. Methods and materials Stereotactic body radiotherapy (SBRT) to 36 Gy in 3 fractions was administered to 23 patients with early glottic cancer T1N0M0. Patients were irradiated with a volumetric intensity modulated arc technique delivered with 6 MV FFF energy. Each patient underwent a pre-treatment cone beam computed tomography (CBCT) to correct the setup based on the thyroid cartilage position. Imaging was repeated if displacement exceeded 2 mm in any direction. CBCT imaging was also performed after each treatment arc as well as at the end of the delivery. Swallowing was allowed only during the beam-off time between arcs. CBCT images were reviewed to evaluate inter- and intra-fraction organ motion. The relationships between selected treatment characteristics, both beam-on and delivery times as well as organ motion were investigated. Results For the population systematic (Ʃ) and random (σ) inter-fraction errors were 0.9, 1.3 and 0.6 mm and 1.1, 1.3 and 0.7 mm in the left-right (X), cranio-caudal (Y) and antero-posterior (Z) directions, respectively. From the analysis of CBCT images acquired after treatment, systematic (Ʃ) and random (σ) intra-fraction errors resulted 0.7, 1.6 and 0.7 mm and 1.0, 1.5 and 0.6 mm in the X, Y and Z directions, respectively. Margins calculated from the intra-fraction errors were 2.4, 5.1 and 2.2 mm in the X, Y and Z directions respectively. A statistically significant difference was found for the displacement in the Z direction between patients irradiated with > 2 arcs versus ≤ 2 arcs, (MW test, p = 0.038). When analyzing mean data from CBCT images for the whole treatment, a significant correlation was found between the time of delivery and the three dimensional displacement vector (r = 0.489, p = 0.055), the displacement in the Y direction (r = 0.553, p = 0.026) and the subsequent margins to be adopted (r = 0.626, p = 0.009). Finally, displacements and the subsequent margins to be adopted in Y direction were significantly greater for treatments with more than 2 arcs (MW test p = 0.037 and p = 0.019, respectively). Conclusions In the setting of controlled swallowing during treatment delivery, intra-fraction motion still needs to be taken into account when planning with estimated CTV to PTV margins of 3, 5 and 3 mm in the X, Y and Z directions, respectively. Selected treatments may require additional margins.


Sign in / Sign up

Export Citation Format

Share Document