da vinci xi
Recently Published Documents


TOTAL DOCUMENTS

163
(FIVE YEARS 89)

H-INDEX

12
(FIVE YEARS 3)

Author(s):  
Georgios Gitas ◽  
I. Alkatout ◽  
L. Proppe ◽  
L. Hanker ◽  
L. Allahqoli ◽  
...  

Abstract Introduction Da-Vinci-Xi is the most recent device used in gynecologic robotic surgery. The aim of the present study was to compare the long-term satisfaction of patients who had undergone conventional laparoscopic hysterectomy or robotic assisted laparoscopic hysterectomy using the Da-Vinci-Xi surgical system. Methods All hysterectomies performed at the University Hospital of Luebeck from 2018 to 2019 were reviewed. Postoperative outcomes were compared between women who had undergone total hysterectomy with da Vinci Xi (n = 42) or conventional laparoscopy (n = 97). Postoperative outcomes included pain, elimination of complaints after surgery, bladder function, sexual function, satisfaction with the cosmetic outcome, positive experiences after robotic surgery, and satisfaction with the surgeon’s preoperative explanation. Obese patients were evaluated separately in a subgroup analysis. Results Both groups had similar baseline characteristics and complication rates. Preoperative complaints subsided after surgery in a little more than 90% of patients. No significant differences were noted between groups in this regard (p = 0.262), or with reference to postoperative pain after one week (p = 0.866) and one month (p = 0.580), stress incontinence (p = 0.343), sexual function (p = 0.766) and the cosmetic outcome of the abdominal incisions (p = 0.273). The majority of patients who had undergone robotic surgery (96.8%) would be willing to undergo the procedure again if necessary. The subgroup analysis of obese patients revealed no significant differences. Conclusion The Da-Vinci-Xi device did not improve the long-term surgical satisfaction of normal-weight or obese patients who underwent hysterectomy compared with patients who underwent conventional laparoscopy performed by experienced laparoscopic surgeons.


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Kun-Yang Lei ◽  
Wen-Jie Xie ◽  
Sheng-Qiang Fu ◽  
Ming Ma ◽  
Ting Sun

Abstract Background To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. Methods We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci Si or Xi surgical systems in our hospital from June 2019 to June 2020. Of the 175 patients, 82 underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Xi surgery system, and 93 patients underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Si surgical system. The perioperative outcomes, short-term efficacy and costs were compared between the two groups. Results The anesthesia time, operation time, docking time, indwelling catheter time and postoperative bed rest time in the Xi group were shorter than those in the Si group (respectively, 268.8 min vs. 219.3 min, P = 0.001; 228.2 min vs. 259.6 min, P < 0.001; 7.4 min vs. 12.7 min, P < 0.001; 8.6 d vs. 9.7 d, P = 0.036; 2.2 d vs. 2.6 d, P = 0.002). However, the total cost of hospitalization and the cost of intraoperative consumables in the Xi group were higher than those in the Si group (84,740.7 vs. 76,739.1 ¥, P = 0.003; 13,199.4 vs. 10,823.0 ¥, P = 0.019). Conclusions Although the cost of robot-assisted radical prostatectomy is higher, compared with the Si system, the Xi system has better perioperative outcomes and can provide similar short-term efficacy and oncology outcomes.


Head & Neck ◽  
2021 ◽  
Author(s):  
Jeroen Meulemans ◽  
Margaux Vanermen ◽  
Ann Goeleven ◽  
Paul Clement ◽  
Sandra Nuyts ◽  
...  

Author(s):  
Gregorio Di Franco ◽  
Valentina Lorenzoni ◽  
Matteo Palmeri ◽  
Niccolò Furbetta ◽  
Simone Guadagni ◽  
...  

Medicina ◽  
2021 ◽  
Vol 57 (10) ◽  
pp. 1130
Author(s):  
Hye Rim Shin ◽  
Keunchul Lee ◽  
Hyeong Won Yu ◽  
Su-jin Kim ◽  
Young Jun Chai ◽  
...  

Background and Objectives: Robotic thyroidectomy via the bilateral axillo-breast approach (BABA), first introduced in Korea in 2008, has become a standard method of thyroid removal worldwide. The introduction of robotic surgical systems has enabled more patients to benefit from BABA robotic thyroidectomy, with good postoperative and excellent cosmetic results. To date, no studies have compared the benefits of the four currently available da Vinci robotic systems (S, Si, X, and Xi) for BABA robotic thyroidectomy. To determine the da Vinci model most suitable for BABA robotic thyroidectomy, the present study compared the perioperative outcomes in patients who underwent BABA robotic thyroidectomy using the four da Vinci models. Materials and Methods: This retrospective study evaluated outcomes in patients (n = 750) who underwent BABA robotic thyroidectomy using the four da Vinci systems from 2013 to 2019. The clinicopathologic data, including operation time, were compared. Substudy A compared the da Vinci models S and Si from 2013 to 2017, and substudy B compared models Si, X, and Xi from 2018 to 2019. Results: Substudy A, comparing the da Vinci S and Si systems, found no statistically significant differences between the two groups, whereas substudy B found that operation time was shorter in patients who underwent BABA robotic thyroidectomy with the da Vinci Xi system than with the Si and X systems. Conclusions: The da Vinci model Xi system can benefit patients undergoing BABA robotic thyroidectomy by shortening the operation time.


2021 ◽  
Vol 50 (8) ◽  
pp. 102131
Author(s):  
Enrica Bentivegna ◽  
Meriem Koual ◽  
Huyên-Thu Nguyen-Xuan ◽  
Laurent Plait ◽  
Stéphanie Seidler ◽  
...  
Keyword(s):  
Da Vinci ◽  

Author(s):  
Min Sun ◽  
Weisi Li ◽  
Cheng Zhang ◽  
Shuangxi Li ◽  
Fayong Zhou ◽  
...  

Sign in / Sign up