infant incubators
Recently Published Documents


TOTAL DOCUMENTS

53
(FIVE YEARS 3)

H-INDEX

9
(FIVE YEARS 1)

2019 ◽  
Vol 21 (3) ◽  
pp. 211
Author(s):  
Nurdina Gita Pratiwi ◽  
Siddiq Wahyu Hidayat ◽  
Wuwus Ardiatna ◽  
Chery Chaen Putri

<p>Infant incubator is one of the most important medical devices for newborn survival, especially preterm. However, aside from its benefits, some irregularities can be found on the devices that could lead to infant mortality, such as temperature deviations. The problem can be minimized by testing the infant incubator temperature parameter in accordance with IEC 60601-2-19 standard. However, there are various types of temperature sensors for related tests. Therefore K-Type and T-Type Thermocouples are compared in order to provide recommendations for infant incubator testing. The measurement technique used were referred to the instructions stated in IEC 60601-2-19 sub-clause Stability (with tolerance ±0.5<sup>o</sup>C) and sub-clause Uniformity (with tolerance ±0.8<sup>o</sup>C). For K-type thermocouples, the highest stability results at 32<sup>o</sup>C is -0.2<sup>o</sup>C and at 36<sup>o</sup>C is -0.4<sup>o</sup>C, while the highest uniformity results at 32<sup>o</sup>C is -0.1<sup>o</sup>C and at 36<sup>o</sup>C is -1.6<sup>o</sup>C, with the uncertainty of 1.7<sup>o</sup>C. For T-type thermocouples, the highest stability results at 32<sup>o</sup>C is 0.4<sup>o</sup>C and at 36<sup>o</sup>C is -0.4<sup>o</sup>C, while the highest uniformity results at 32<sup>o</sup>C is 0.7<sup>o</sup>C and at 36<sup>o</sup>C is 0.8<sup>o</sup>C, with the uncertainty of 0.3<sup>o</sup>C. The results of the independent t-test showed a different average, where the T-type thermocouples was higher than the K-type thermocouples. In other words, T-type thermocouples could be recommended for infant incubators testing.</p>


2019 ◽  
pp. 483-490 ◽  
Author(s):  
Lemana Spahić ◽  
Emina Kurta ◽  
Sabahudin Ćordić ◽  
Merjem Bećirović ◽  
Lejla Gurbeta ◽  
...  

2019 ◽  
Vol 67 (3) ◽  
pp. 168-179
Author(s):  
Lichuan Liu ◽  
Lilin Du ◽  
Ajit Kolla ◽  
Sen M. Kuo

This research proposes to develop a wireless communication integrated hybrid active noise control (ANC) system for infant incubators. The integrated ANC system will reduce the level of noise in the infant's ear and provide two-way wireless communication between infant and his/her parents/caregivers both inside and outside the Neonatal Intensive Care Unit (NICU). The proposed system will use the ANC technique to reduce the harmful noise. The wireless communication system will be used to reduce stress and improve bonding and language development. The real-time experiments show that the proposed system can significantly reduce the noise exposure to the infants who are placed in infant incubators. Consequently, a reduction in the health risk produced by high-level noise in NICU and improved bonding opportunities for infants and their parents will be seen.


2018 ◽  
Vol 20 (1) ◽  
pp. 29-33
Author(s):  
Ukurta Tarigan ◽  
Rosnani Ginting

A Newborns need special attention because it takes time to adapt to the outside world. In accordance with the standard post-neonatal procedures, newborns should be incorporated into the incubator within a certain period of time according to the infant's health level. Infant incubator as a medical device used to care for newborns, often get complaints from doctors and child nurses. The complaint indicates consumer dissatisfaction with infant incubator products in the hospital. Broadly speaking, complaints against infant incubators lie in inappropriate designs. To overcome these complaints the researchers apply the method of Kano to determine the satisfaction frome every technical characteristics. Through the mapping can be seen that from the seven attributes that become the question, there are two attributes that are in the category of Attractive namely "Additional Functions on Infant Incubator the Place Tube Oxygen" and "Size Door Holes is 15 cm". There is one attribute that is in the One Dimensional category that is "Infant Incubator Price Rp 10.000.000". While the four attributes are in the category Must be "Infant Incubator Dimension 70 cm x 50 cm x 40 cm", "The distance of the floor from the base of the compartment 100 cm", "Compartment infant incubator materials are Acrylic" and "The position of the controller on the infant incubator is in top right side ".


2017 ◽  
Vol 25 (2) ◽  
pp. 237-250 ◽  
Author(s):  
Almir Badnjevic ◽  
Lejla Gurbeta ◽  
Elvira Ruiz Jimenez ◽  
Ernesto Iadanza

2016 ◽  
Vol 3 ◽  
pp. 46-65
Author(s):  
Nikole Darnell ◽  
Kathryn Hampshire ◽  
Amory Orchard

Today, Coney Island is known for family fun andentertainment. But few people realize that at onetime it was home to the first infant incubators in thenation. By examining the history of these incubators, putting children on display without their directconsent, and the psychology of cute, the authorsdelve into the darker side of Coney Island’s history.


2013 ◽  
Vol 102 (16) ◽  
pp. 161913 ◽  
Author(s):  
Kazuki Tajima ◽  
Mika Shimoike ◽  
Heng Li ◽  
Masumi Inagaki ◽  
Hitomi Izumi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document