survivorship analysis
Recently Published Documents


TOTAL DOCUMENTS

169
(FIVE YEARS 26)

H-INDEX

41
(FIVE YEARS 2)

Author(s):  
Antonio Clemente ◽  
Luca Cavagnaro ◽  
Antonio Russo ◽  
Francesco Chiarlone ◽  
Alessandro Massè ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yoon Joo Cho ◽  
Jong-Beom Park ◽  
Dong-Gune Chang ◽  
Hong Jin Kim

Abstract Background Interspinous devices have been introduced as alternatives to decompression or fusion in surgery for degenerative lumbar diseases. This study aimed to investigate 15-year survivorship and risk factors for reoperation of a Device for Intervertebral Assisted Motion (DIAM) in surgery for 1-level lumbar disc herniation (LDH). Methods A total of 94 patients (54 men and 40 women) underwent discectomy and DIAM implantation for 1-level LDH, with a mean follow-up of 12.9 years (range, 6.3–15.3 years). The mean age was 46.2 years (range, 21–65 years). Sixty-two patients underwent DIAM implantation for L4–5, 27 for L5–6, and 5 for L3–4. Reoperations due to any reason associated with DIAM implantation level or adjacent levels were defined as failure and used as the end point of determining survivorship. Results During the 15-year follow-up, 8 patients (4 men and 4 women) underwent reoperation due to recurrence of LDH at the DIAM implantation level, a reoperation rate of 8.5%. The mean time to reoperation was 6.5 years (range, 0.8–13.9 years). Kaplan-Meier analysis showed a cumulative survival rate of the DIAM implantation of 97% at 5 years, 93% at 10 years, and 92% at 15 years after surgery; the cumulative reoperation rate of the DIAM implantation was 3% at 5 years, 7% at 10 years, and 8% at 15 years after surgery. Mean survival time was predicted to be 14.5 years (95% CI, 13.97–15.07). The log-rank test and Cox proportional hazard model showed that age, sex, and location did not significantly affect the reoperation rate of DIAM implantation. Conclusions Our results showed that DIAM implantation significantly decreased reoperation rate for LDH in the 15-year survivorship analysis. We suggest that DIAM implantation could be considered a useful intermediate step procedure for LDH surgery. To the best of our knowledge, this is the longest follow-up study in which surgical outcomes of interspinous device surgery were reported.


2021 ◽  
Vol 87 (3) ◽  
pp. 393-399
Author(s):  
Fernando Almeida ◽  
Silvia Gállego ◽  
Francisco Argüelles ◽  
Antonio Silvestre

This study investigates the clinical and radiological results of a tapered femoral stem (Corail®) and uncemented threaded acetabular cups (Tropic®) and in addition an analysis of the complications and retrieved implants was conducted. Between January 1990 and September 1998, 301 total hips arthroplasties in 268 patients were implanted. 78 patients (87 hips) had died and 9 patients (12 hips) had been lost to follow-up, leaving at the time of the latest follow-up 180 patients (202 hips). The mean age at surgery was 56,1 (27-75) years. Of the 154 unrevised hips, the median Harris and Merle d´Aubigne and Postel hip scores were 83,3 points and 15,3 points respectively at the latest follow-up. The median follow-up time was 16.9 years (10,4-25). No femoral component was revised for aseptic loosening ; osteolysis was observed in the 9,5% of the implants (13 stems). 48 hips (23%) were revised and 27 cups (56,2%) needed revision surgery because of massive polyethylene wear. Pelvic osteolysis was found out in 80 cups (58,8%). 87 hips (63,9%) showed signs of a progressive wear of the liner, more than 2mm in 48 hips. Kaplan-Meier survivorship analysis at 15 years follow-up was 81.2% with revision for any reason (85.8% for mechanical or radiographic loosening). High rates of polyethylene wear and the high prevalence of pelvic osteolysis are serious matters in these types of implants with high rates of revision at 15 years follow-up so we decided to abandon the concept of a threaded cup design in favor of a press-fit acetabular cup.


2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Ng Jonathan Patrick ◽  
Lau Lawrence Chun Man ◽  
Chau Wai-Wang ◽  
Ong Michael Tim-Yun ◽  
Cheung Kin Wing ◽  
...  

Abstract Background The literature comparing the long-term outcomes and survivorship of computer navigation-assisted and conventional total knee replacement (TKR) is sparse. Moreover, of the available comparative studies with follow-up duration of more than 10 years, the results seem to be conflicting. The purpose of this long-term study was to compare the clinical and radiological outcomes, and implant survivorship, of TKR performed with and without computer navigation. Methods We retrospectively compared the results of 49 computer-navigated TKRs and 139 conventional TKRs. The mean age of the patients was 67.9 (range 52–81) years for the navigation group and 67.1 (range 50–80) years for the conventional TKR group. The mean duration of follow-up for the conventional and navigation TKR groups was 12.9 and 13.2 years, respectively. Clinical and radiographic follow-up examinations of the patients were performed at 2 weeks, 1 month, 3 months and 6 months post-operatively, and at 1-year intervals thereafter. Results There were no significant differences in the post-operative Knee Society knee and function score between the two groups. The mean overall deviation from neutral alignment and the radiological outliers were significantly higher in the conventional TKR group. The overall survival rates at 17 years were 92.9% for the navigation group and 95.6% for the conventional TKR group (p = 0.62). Conclusions Navigated TKR resulted in fewer radiological outliers; however, this did not translate to better long-term functional outcomes or implant survival.


2021 ◽  
pp. 112070002110401
Author(s):  
David Yeroushalmi ◽  
Vivek Singh ◽  
Nolan Maher ◽  
Jonathan A Gabor ◽  
Joseph D Zuckerman ◽  
...  

Introduction: Third-generation hemispheric, titanium porous-coated (HTPC) acetabular cups have been shown to achieve good biologic fixation through enhanced porous ingrowth surfaces. They also allow for a wide range of bearing options, including polyethylene, dual-mobility, and ceramic liners. The purpose of the study is to review the mid-term clinical outcomes an HTPC acetabular cup with a minimum of 7-year follow-up. Methods: A retrospective, observational study was conducted on all consecutive patients who underwent total hip arthroplasty (THA) with an HTCP acetabular cup at an urban, tertiary referral centre. Descriptive statistics were used describe baseline patient characteristics. Outcomes collected included postoperative complications, survival free of reoperations, and presence of osteolysis at latest imaging follow-up. Implant survival was analysed using the Kaplan-Meier method. Results: 118 cases (114 primary, 4 revision) underwent THA with the HTCP acetabular cup at an average follow-up of 8.16 ± 0.85 years (range 7.02–10.28 years). Mean patient age at the time of surgery was 61.29 ± 12.04 years. All cases utilised a high-molecular-weight polyethylene (HMWPE) liner. None of the acetabular cups showed loosening or migration at the latest follow-up. There were 2 revisions in our study, 1 for abductor mechanism disruption and 1 due to surgical site infection where the acetabular cup was revised. Kaplan-Meier survivorship analysis for all-cause revision at 7 and 10-year follow-up showed a survival rate of 99.1% (95% confidence interval, 94.1–99.9%). Survivorship analysis for aseptic acetabular revision at 10-year follow-up showed a survival rate of 100%. Conclusions: At long-term follow-up, no radiologic and minimal clinical complications were identified in this series. The HTPC acetabular cup system, used in conjunction with a HMWPE liner, demonstrates excellent outcomes and survivorship when compared to earlier mid-term studies published in the literature.


2021 ◽  
Vol 90 ◽  
pp. 135-139
Author(s):  
Peter G. Passias ◽  
Haddy Alas ◽  
Nicholas Kummer ◽  
Oscar Krol ◽  
Lara Passfall ◽  
...  

2021 ◽  
Vol 11 (8) ◽  
pp. 753
Author(s):  
Cyrus Anthony Pumilia ◽  
Lennart Schroeder ◽  
Nana O. Sarpong ◽  
Gregory Martin

Customized unicompartmental knee arthroplasty (C-UKA) utilizes implants manufactured on an individual patient basis, derived from pre-operative computed tomography images in an effort to more closely approximate the natural anatomy of the knee. The outcomes from 349 medial and lateral fixed-bearing C-UKA were reviewed. Implant survivorship analysis was conducted via retrospective chart review, and follow-up analysis was conducted via a single postoperative phone call or email. The rate of follow-up was 69% (242 knees). The average age at surgery was 71.1 years and the average body mass index was 28.8 kg/m2. Seven revision arthroplasties (2.1%) had knowingly been performed at an average of 1.9 years postoperatively (range: 0.1–3.9 years), resulting in an implant survivorship of 97.9% at an average follow-up of 4.2 years (range: 0.1–8.7) and 97.9% at an average of 4.8 years (range: 2.0–8.7) when knees with less than two years of follow-up were excluded. The reasons for revision were implant loosening (one knee), infection (two knees), progression of osteoarthritis (two knees), and unknown reasons (two knees). The average KOOS, JR. interval score was 84 (SD: 14.4). Of those able to be contacted for follow-up analysis, 67% were “very satisfied,” 26% were “satisfied,” 4% were “neutral,” 2% were “dissatisfied,” and 1% were “very dissatisfied.” When asked if the knee felt “natural,” 60% responded with “always,” 35% responded with “sometimes,” and 5% responded with “never.” After analyzing a large cohort of C-UKA, we found favorable rates of survivorship, satisfaction, and patient-reported functional outcomes.


Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3895
Author(s):  
Marica Baldoni ◽  
Alessandra Nardi ◽  
Flavio De Angelis ◽  
Olga Rickards ◽  
Cristina Martínez-Labarga

The present research investigates the relationship between dietary habits and mortality patterns in the Roman Imperial and Medieval periods. The reconstructions of population dynamics and subsistence strategies provide a fascinating source of information for understanding our history. This is particularly true given that the changes in social, economic, political, and religious aspects related to the transition from the Roman period to the Middle Ages have been widely discussed. We analyzed the isotopic and mortality patterns of 616 individuals from 18 archeological sites (the Medieval Latium sites of Colonna, Santa Severa, Allumiere, Cencelle, and 14 Medieval and Imperial funerary contexts from Rome) to compile a survivorship analysis. A semi-parametric approach was applied, suggesting variations in mortality patterns between sexes in the Roman period. Nitrogen isotopic signatures influenced mortality in both periods, showing a quadratic and a linear effect for Roman Imperial and Medieval populations, respectively. No influence of carbon isotopic signatures has been detected for Roman Imperial populations. Conversely, increased mortality risk for rising carbon isotopic values was observed in Medieval samples.


2021 ◽  
pp. 175857322110241
Author(s):  
Aparna I Viswanath ◽  
Adam C Watts

Background Restoring the radial head as a stabiliser of the elbow is considered important in cases where there is an associated bony or ligamentous injury. A variety of radial head prostheses are available. There are no reports of the survivorship of a short-stem press-fit radial head prostheses with pyrocarbon bearing. Patients and methods With institutional review board approval, a retrospective case-note analysis was performed of a consecutive single-surgeon case series of the Integra LifeScience pyrocarbon radial head prostheses (Carbon Modular Radial Head) from October 2010 to October 2019 in a tertiary referral centre. The series was divided into acute trauma and salvage cohorts. Kaplan–Meier survivorship analysis was conducted. Results 36 patients were included, 23 (64%) for acute injuries and 13 (36%) for failed initial treatment. Of the acute injuries, 20 (87%) had a Wrightington type-C elbow fracture-dislocation. Reoperation was performed in 4 (11%) patients; 10 (28%) had possible loosening on radiographs. The implant survival rate was 94% at shortest follow-up of 17 months (mean 70 months). Discussion Treatment of complex radial head fractures using a pyrocarbon-bearing, anatomic press-fit design provides satisfactory short-term survivorship in this case series. The implant should be used with caution in salvage cases, due to higher rates of loosening seen in this cohort.


2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 158-164 ◽  
Author(s):  
Nicholas M. Hernandez ◽  
Zoe W. Hinton ◽  
Christine J. Wu ◽  
Sean P. Ryan ◽  
Michael P. Bolognesi

Aims Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. Because there are few studies evaluating mid-term outcomes with a sufficient cohort, the purpose of this study was to evaluate tibial cone survival and complications in revision TKAs with tibial cones at minimum follow-up of five years. Methods A retrospective review was completed from September 2006 to March 2015, evaluating 67 revision TKAs (64 patients) that received one specific porous tibial cone during revision TKA. The final cohort was composed of 62 knees (59 patients) with five years of clinical follow-up or reoperation. The mean clinical follow-up of the TKAs with minimum five-year clinical follow-up was 7.6 years (5.0 to 13.3). Survivorship analysis was performed with the endpoints of tibial cone revision for aseptic loosening, tibial cone revision for any reason, and reoperation. We also evaluated periprosthetic joint infection (PJI), risk factors for failure, and performed a radiological review. Results The rate of cone revision for aseptic loosening was 6.5%, with an eight-year survival of 95%. Significant bone loss (Anderson Orthopaedic Research Institute grade 3) was associated with cone revision for aseptic loosening (p = 0.002). The rate of cone revision for any reason was 17.7%, with an eight-year survival of 84%. Sixteen percent of knees developed PJI following revision. A pre-revision diagnosis of reimplantation as part of a two-stage exchange protocol for infection was associated with both PJI (p < 0.001) and tibial cone revision (p = 0.001). Conclusion Mid-term results of tibial cones showed a survivorship free of cone revision for aseptic loosening of 95%. Patients with significant bone loss were more likely to have re-revision for tibial cone failure. Infection was common, and patients receiving cones at reimplantation were more likely to develop PJI and undergo cone revision. Cite this article: Bone Joint J 2021;103-B(6 Supple A):158–164.


Sign in / Sign up

Export Citation Format

Share Document