panel absorber
Recently Published Documents


TOTAL DOCUMENTS

53
(FIVE YEARS 21)

H-INDEX

10
(FIVE YEARS 3)

2021 ◽  
Vol 69 (6) ◽  
pp. 507-517
Author(s):  
Woong-yong Lee ◽  
Jae-chul Kim ◽  
Hee-min Noh

A micro-perforated panel absorber (MPPA) can reduce noise without the use of sound-absorbing materials. It is made of various materials and is poten- tially applicable in a variety of fields. However, the application of MPPAs is limited owing to the narrow absorption band. In a previous study, to enhance the sound- absorption performance of MPPAs, we proposed a parallel arrangement of multi- layer MPPAs. Based on the results of this previous study, we carried out the present study to apply an MPPA to the curve squeal noise of railways. Squeal noise, which occurs at approximately 500 to 5000 Hz, has high-level peaks. We designed and fabricated an MPPAwith the proposed structure according to the characteris- tics of the squeal noise. The noise reduction was analyzed after an MPPA barrier was installed in the field with a curve radius of 120 m. The reduction in noise level was approximately 17 dB(A) on the first floor and approximately 7 dB(A) on the fourth floor of the building. At 630 to 5000 Hz, the noise reduction level was at least approximately 5 dB(A). To analyze the noise absorption effect of the MPPA bar- rier, a simulation was carried out and subsequently verified by comparing the measurement results with the simulation results. In the simulation, the difference in noise reduction level between the MPPA and reflective barrier was analyzed. The noise reduction level of the MPPA barrier was approximately 7.5 dB(A) higher than that of the reflective barrier on the second and third floors of the build- ing at 630 to 5000 Hz. These results support the viability of MPPA application in re- ducing noise from curve squeal noise.


Author(s):  
Mohamed Thalib Mohamed Rafeek ◽  
Vimala Muthu ◽  
Muthu Manokar Athikesavan ◽  
Ravishankar Sathyamurthy ◽  
Abd Elnaby Kabeel

Symmetry ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1188
Author(s):  
Yiu-Yin Lee

This study addresses the frequency–amplitude relationship of a nonlinear symmetric panel absorber mounted on a flexible wall. In many structural–acoustic works, only one flexible panel is considered in their models with symmetric configuration. There are very limited research investigations that focus on two flexible panels coupled with a cavity, particularly for nonlinear structural–acoustic problems. In practice, panel absorbers with symmetric configurations are common and usually mounted on a flexible wall. Thus, it should not be assumed that the wall is rigid. This study is the first work employing the weighted residual elliptic integral method for solving this problem, which involves the nonlinear multi-mode governing equations of two flexible panels coupled with a cavity. The reason for adopting the proposed solution method is that fewer nonlinear algebraic equations are generated. The results obtained from the proposed method and finite element method agree reasonably well with each other. The effects of some parameters such as vibration amplitude, cavity depth and thickness ratio, etc. are also investigated.


Sign in / Sign up

Export Citation Format

Share Document