speech perception in noise
Recently Published Documents


TOTAL DOCUMENTS

259
(FIVE YEARS 75)

H-INDEX

31
(FIVE YEARS 4)

2022 ◽  
Vol 12 ◽  
Author(s):  
Yuan Chen ◽  
Lena L. N. Wong ◽  
Shaina Shing Chan ◽  
Joannie Yu

Chinese-speaking older adults usually do not perceive a hearing problem until audiometric thresholds exceed 45 dB HL, and the audiometric thresholds of the average hearing-aid (HA) user often exceed 60 dB HL. The purpose of this study was to examine the relationships between cognitive and hearing functions (measured as audiometric or speech reception thresholds) in older Chinese adults with HAs and with untreated hearing loss (HL). Participants were 49 Chinese older adults who used HAs and had moderate to severe HL (HA group), and 46 older Chinese who had mild to moderately severe HL but did not use HAs (untreated; or UT group). Multiple linear regression analysis was employed to evaluate how well age, education level, audiometric thresholds, and speech perception in noise were related to performance on general cognitive function, working memory, executive function, attention, and verbal learning tests. Results showed that speech perception in noise alone accounted for 13–25% of the variance in general cognitive function, working memory, and executive function in the UT group, and 9–21% of the variance in general cognitive function and verbal learning in the HA group (i.e., medium effect sizes). Audiometric thresholds did not explain any proportion of the variance in cognitive functioning in the HA or UT group. Thus, speech perception in noise accounts for more variance in cognitive performance than audiometric thresholds, and is significantly associated with different cognitive functions in older Chinese adults with HAs and with untreated HL.


Author(s):  
Elahe Nasiri ◽  
Hamid Jalilvand ◽  
Nasrin Yazdani ◽  
Alireza Akbarzadeh Baghban

Background and Aim: Noise tolerance and performance in noisy environments are influential factors of hearing aid use in people with hearing loss. One of the causes of hearing loss is Meniere’s disease (MD), which affects speech perception in noise. Acceptable noise level (ANL) is a test that measures the maximum tolerated background noise level (BNL) while listening to the running speech. Since the effect of MD on ANL needs further study, the present study aims to examine the ANL test results in people with unilateral MD, and compare the results between the two ears. Methods: This cross sectional study conducted on 33 individuals with unilateral MD (21 females and 12 males) aged 32–60 years who had the disease for at least one year, who participated in this study. Their most comfortable level (MCL), BNL, and ANL in both ears were then evaluated. Results: The mean MCL and BNL were significantly different between the two ears, where they were higher in the affected ear than in the contralateral ear. There was also a significant difference in the ANL results between the two ears. In the affected ear, a statistically significant relationship was reported between the ANL and the average hearing thresholds at frequencies of 250, 500, and 1000 Hz. Conclusion: MD affects the ANL in the affected ear and causes a deterioration in its level and speech perception in noise.


2021 ◽  
Vol 12 ◽  
Author(s):  
Beula M. Magimairaj ◽  
Naveen K. Nagaraj ◽  
Craig A. Champlin ◽  
Linda K. Thibodeau ◽  
Diane F. Loeb ◽  
...  

We examined the relative contribution of auditory processing abilities (tone perception and speech perception in noise) after controlling for short-term memory capacity and vocabulary, to narrative language comprehension in children with developmental language disorder. Two hundred and sixteen children with developmental language disorder, ages 6 to 9 years (Mean = 7; 6), were administered multiple measures. The dependent variable was children's score on the narrative comprehension scale of the Test of Narrative Language. Predictors were auditory processing abilities, phonological short-term memory capacity, and language (vocabulary) factors, with age, speech perception in quiet, and non-verbal IQ as covariates. Results showed that narrative comprehension was positively correlated with the majority of the predictors. Regression analysis suggested that speech perception in noise contributed uniquely to narrative comprehension in children with developmental language disorder, over and above all other predictors; however, tone perception tasks failed to explain unique variance. The relative importance of speech perception in noise over tone-perception measures for language comprehension reinforces the need for the assessment and management of listening in noise deficits and makes a compelling case for the functional implications of complex listening situations for children with developmental language disorder.


2021 ◽  
pp. 1-11
Author(s):  
Chandni Jain ◽  
Vipin Ghosh Pushpoth Gangadharan ◽  
Chetak Kadabasal Basavaraja ◽  
Aishwarya Lakshmi

Purpose This study evaluated the peripheral hearing and central auditory processing abilities in Indian adolescent girls with iron deficiency anemia (IDA). Method The participants consisted of 75 adolescent girls with IDA, 50 adolescent girls without IDA, and 50 adolescent boys without IDA. Participants underwent a test battery to evaluate auditory processing and peripheral hearing assessment. In this study, central auditory processing abilities were assessed using Speech Perception in Noise test in Kannada (SPIN-K) and quick speech perception in noise tests in Kannada, dichotic consonant–vowel test, gap detection threshold (GDT), and auditory digit sequencing and auditory digit span tests. Results Results showed that the hearing thresholds at extremely low and high frequencies (250 and 8000 Hz), although within clinically normal limits, were poorer in girls with IDA than in the control groups. Also, girls with IDA performed poorly in SPIN-K of the right ear, GDT, and auditory backward digit span tests. Conclusion These subtle auditory deficiencies may be attributed to the compromised blood supply to the central auditory nervous system, as observed in the current study.


PLoS ONE ◽  
2021 ◽  
Vol 16 (10) ◽  
pp. e0257447
Author(s):  
Jeroen P. M. Peters ◽  
Jan A. A. van Heteren ◽  
Anne W. Wendrich ◽  
Gijsbert A. van Zanten ◽  
Wilko Grolman ◽  
...  

Single-sided deafness (SSD) leads to difficulties with speech perception in noise, sound localisation, and sometimes tinnitus. Current treatments (Contralateral Routing of Sound hearing aids (CROS) and Bone Conduction Devices (BCD)) do not sufficiently overcome these problems. Cochlear implants (CIs) may help. Our aim was to evaluate these treatments in a Randomised Controlled Trial (RCT). Adult SSD patients were randomised using a web-based randomisation tool into one of three groups: CI; trial period of ‘first BCD, then CROS’; trial period of ‘first CROS, then BCD’. After these trial periods, patients opted for BCD, CROS, or No treatment. The primary outcome was speech perception in noise (directed from the front (S0N0)). Secondary outcomes were speech perception in noise with speech directed to the poor ear and noise to the better ear (SpeNbe) and vice versa (SbeNpe), sound localisation, tinnitus burden, and disease-specific quality of life (QoL). We described results at baseline (unaided situation) and 3 and 6 months after device activation. 120 patients were randomised. Seven patients did not receive the allocated intervention. The number of patients per group after allocation was: CI (n = 28), BCD (n = 25), CROS (n = 34), and No treatment (n = 26). In S0N0, the CI group performed significantly better when compared to baseline, and when compared to the other groups. In SpeNbe, there was an advantage for all treatment groups compared to baseline. However, in SbeNpe, BCD and CROS groups performed worse compared to baseline, whereas the CI group improved. Only in the CI group sound localisation improved and tinnitus burden decreased. In general, all treatment groups improved on disease-specific QoL compared to baseline. This RCT demonstrates that cochlear implantation for SSD leads to improved speech perception in noise, sound localisation, tinnitus burden, and QoL after 3 and 6 months of follow-up. For most outcome measures, CI outperformed BCD and CROS. Trial registration: Netherlands Trial Register (www.trialregister.nl): NTR4580, CINGLE-trial.


2021 ◽  
Vol 25 (4) ◽  
pp. 171-177
Author(s):  
Subin Kim ◽  
Sungwha You ◽  
Myoung Eun Sohn ◽  
Woojae Han ◽  
Jae-Hyun Seo ◽  
...  

Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice.Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test.Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants’ qualitative reports than the K-SPIN test.Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.


Sign in / Sign up

Export Citation Format

Share Document