body segment parameters
Recently Published Documents


TOTAL DOCUMENTS

71
(FIVE YEARS 8)

H-INDEX

15
(FIVE YEARS 1)

PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0262296
Author(s):  
Pawel Kudzia ◽  
Erika Jackson ◽  
Genevieve Dumas

Body segment parameters are inputs for a range of applications. Participant-specific estimates of body segment parameters are desirable as this requires fewer prior assumptions and can reduce outcome measurement errors. Commonly used methods for estimating participant-specific body segment parameters are either expensive and out of reach (medical imaging), have many underlying assumptions (geometrical modelling) or are based on a specific subset of a population (regression models). Our objective was to develop a participant-specific 3D scanning and body segmentation method that estimates body segment parameters without any assumptions about the geometry of the body, ethnic background, and gender, is low-cost, fast, and can be readily available. Using a Microsoft Kinect Version 2 camera, we developed a 3D surface scanning protocol that enabled the estimation of participant-specific body segment parameters. To evaluate our system, we performed repeated 3D scans of 21 healthy participants (10 male, 11 female). We used open source tools to segment each body scan into 16 segments (head, torso, abdomen, pelvis, left and right hand, forearm, upper arm, foot, shank and thigh) and wrote custom software to estimate each segment’s mass, mass moment of inertia in the three principal orthogonal axes relevant to the center of the segment, longitudinal length, and center of mass. We compared our body segment parameter estimates to those obtained using two comparison methods and found that our system was consistent in estimating total body volume between repeated scans (male p = 0.1194, female p = 0.2240), estimated total body mass without significant differences when compared to our comparison method and a medical scale (male p = 0.8529, female p = 0.6339), and generated consistent and comparable estimates across a range of the body segment parameters of interest. Our work here outlines and provides the code for an inexpensive 3D surface scanning method for estimating a range of participant-specific body segment parameters.


Author(s):  
Osvaldo COSTA MOREIRA ◽  
Cláudia E. PATROCÍNIO DE OLIVEIRA ◽  
Dihogo G. DE MATOS ◽  
Mauro L. MAZINI FILHO ◽  
Sandro FERNANDES DA SILVA ◽  
...  

2021 ◽  
Author(s):  
Pawel Kudzia ◽  
Erika A. Jackson ◽  
Genevieve A. Dumas

Body segment parameters are inputs for a range of applications. The estimation of body segment parameters that are participant-specific is desirable as it requires fewer prior assumptions and can reduce outcome measurement errors. Commonly used methods for estimating participant-specific body segment parameters are either expensive and out of reach (medical imaging), have many underlying assumptions (geometrical modelling) or are based on a specific subset of a population (regression models). Our objective was to develop a participant-specific 3D scanning and body segmentation method that estimates body segment parameters without any assumptions about the geometry of the body, ethnic background, and gender, is low-cost, fast, and can be readily available. Using a Microsoft Kinect camera, we developed a 3D surface scanning protocol that estimated participant-specific body segment parameters. To evaluate our system, we performed repeated 3D scans of 21 healthy participants (10 male, 11 female). We used open-source software to segment each body scan into 16 segments (head, torso, abdomen, pelvis, left and right hand, forearm, upper arm, foot, shank and thigh) and wrote custom software to estimate each segment's mass, mass moment of inertia in the three principal orthogonal axes relevant to the center of the segment, longitudinal length, and center of mass. We compared our body segment parameter estimates to those obtained using two comparison methods and found that our system was consistent in estimating total body volume between repeated scans (male p=0.1194, female p = 0.2240), estimated total body mass without significant differences when compared to our comparison method and a medical scale (male p=0.8529, female p = 0.6339), and generated consistent and comparable estimates across all of the body segment parameters of interest. The work here outlines an inexpensive 3D surface scanning approach for estimating a range of participant-specific body segment parameters.


2021 ◽  
Vol 8 (6) ◽  
pp. 210836
Author(s):  
Samuel J. Coatham ◽  
William I. Sellers ◽  
Thomas A. Püschel

Obtaining accurate values for body segment parameters (BSPs) is fundamental in many biomechanical studies, particularly for gait analysis. Convex hulling, where the smallest-possible convex object that surrounds a set of points is calculated, has been suggested as an effective and time-efficient method to estimate these parameters in extinct animals, where soft tissues are rarely preserved. We investigated the effectiveness of convex hull BSP estimation in a range of extant mammals, to inform the potential future usage of this technique with extinct taxa. Computed tomography scans of both the skeleton and skin of every species investigated were virtually segmented. BSPs (the mass, position of the centre of mass and inertial tensors of each segment) were calculated from the resultant soft tissue segments, while the bone segments were used as the basis for convex hull reconstructions. We performed phylogenetic generalized least squares and ordinary least squares regressions to compare the BSPs calculated from soft tissue segments with those estimated using convex hulls, finding consistent predictive relationships for each body segment. The resultant regression equations can, therefore, be used with confidence in future volumetric reconstruction and biomechanical analyses of mammals, in both extinct and extant species where such data may not be available.


2019 ◽  
Author(s):  
Brock Laschowski ◽  
Reza Sharif Razavian ◽  
John McPhee

AbstractAlthough regenerative actuators can extend the operating durations of robotic lower-limb exoskeletons and prostheses, these energy-efficient powertrains have been exclusively designed and evaluated for continuous level-ground walking.ObjectiveHere we analyzed the lower-limb joint mechanical power during stand-to-sit movements using inverse dynamic simulations to estimate the biomechanical energy available for electrical regeneration.MethodsNine subjects performed 20 sitting and standing movements while lower-limb kinematics and ground reaction forces were measured. Subject-specific body segment parameters were estimated using parameter identification, whereby differences in ground reaction forces and moments between the experimental measurements and inverse dynamic simulations were minimized. Joint mechanical power was calculated from net joint torques and rotational velocities and numerically integrated over time to determine joint biomechanical energy.ResultsThe hip produced the largest peak negative mechanical power (1.8 ± 0.5 W/kg), followed by the knee (0.8 ± 0.3 W/kg) and ankle (0.2 ± 0.1 W/kg). Negative mechanical work from the hip, knee, and ankle joints per stand-to-sit movement were 0.35 ± 0.06 J/kg, 0.15 ± 0.08 J/kg, and 0.02 ± 0.01 J/kg, respectively.Conclusion and SignificanceAssuming an 80-kg person and previously published regenerative actuator efficiencies (i.e., maximum 63%), robotic lower-limb exoskeletons and prostheses could theoretically regenerate ~26 Joules of total electrical energy while sitting down, compared to ~19 Joules per walking stride. Given that these regeneration performance calculations are based on healthy young adults, future research should include seniors and/or rehabilitation patients to better estimate the biomechanical energy available for electrical regeneration among individuals with mobility impairments.


2019 ◽  
Vol 88 ◽  
pp. 38-47 ◽  
Author(s):  
Zachary Merrill ◽  
Subashan Perera ◽  
April Chambers ◽  
Rakié Cham

Author(s):  
Zachary Merrill ◽  
Subashan Perera ◽  
Rakié Cham

Body segment parameters (BSPs) such as segment mass, center of mass, and radius of gyration are used as inputs in static and dynamic ergonomic and biomechanical models used to predict joint and muscle forces, and related risks of musculoskeletal injury. Because these models are sensitive to BSP values, accurate and representative parameters are necessary for injury risk prediction. While previous studies have determined segment parameters in the general population, as well as the impact of age and obesity levels on these parameters, estimated errors in the prediction of BSPs can be as large as 40% (Durkin, 2003). Thus, more precise values are required for attempting to predict injury risk in individuals. This study aims to provide statistical models for predicting torso segment parameters in working adults using whole body dual energy x-ray absorptiometry (DXA) scan data along with a set of anthropometric measurements. The statistical models were developed on a training subset of the study population, and validated on a testing subset. When comparing the model predictions to the actual BSPs of the testing subset, the predictions were, on average, within 5% of the calculated parameters, while previously developed predictions (de Leva, 1996) had average errors of up to 30%, indicating that the new statistical models greatly increase the accuracy in predicting BSPs.


Sign in / Sign up

Export Citation Format

Share Document