loading conditions
Recently Published Documents


TOTAL DOCUMENTS

3817
(FIVE YEARS 859)

H-INDEX

73
(FIVE YEARS 10)

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 509
Author(s):  
Housseme Ben Boubaker ◽  
Pascal Laheurte ◽  
Gael Le Coz ◽  
Seyyed-Saeid Biriaie ◽  
Paul Didier ◽  
...  

In order to simulate micromachining of Ti-Nb medical devices produced in situ by selective laser melting, it is necessary to use constitutive models that allow one to reproduce accurately the material behavior under extreme loading conditions. The identification of these models is often performed using experimental tension or compression data. In this work, compression tests are conducted to investigate the impact of the loading conditions and the laser-based powder bed fusion (LB-PBF) building directions on the mechanical behavior of β-Ti42Nb alloy. Compression tests are performed under two strain rates (1 s−1 and 10 s−1) and four temperatures (298 K, 673 K, 873 K and 1073 K). Two LB-PBF building directions are used for manufacturing the compression specimens. Therefore, different metallographic analyses (i.e., optical microscopy (OM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), electron backscatter diffraction (EBSD) and X-ray diffraction) have been carried out on the deformed specimens to gain insight into the impact of the loading conditions on microstucture alterations. According to the results, whatever the loading conditions are, specimens manufactured with a building direction of 45∘ exhibit higher flow stress than those produced with a building direction of 90∘, highlighting the anisotropy of the as-LB-PBFed alloy. Additionally, the deformed alloy exhibits at room temperature a yielding strength of 1180 ± 40 MPa and a micro-hardness of 310 ± 7 HV0.1. Experimental observations demonstrated two strain localization modes: a highly deformed region corresponding to the localization of the plastic deformation in the central region of specimens and perpendicular to the compression direction and an adiabatic shear band oriented with an angle of ±45 with respect to same direction.


2022 ◽  
Vol 12 (2) ◽  
pp. 604
Author(s):  
Zhengdong Li ◽  
Donghua Zou ◽  
Jianhua Zhang ◽  
Kaijun Ma ◽  
Yijiu Chen

This study aimed to systematically simulate the responses of pelvic fracture under impact and run-over to clarify the effects of boundary and loading conditions on the pelvic fracture mechanism and provide complementary quantitative evidence for forensic practice. Based on the THUMS finite element model, we have validated the simulation performance of the model by a real postmortem human pelvis side impact experiment. A total of 54 simulations with two injury manners (impact and run-over), seven loading directions (0°, 30°, 60°, 90°, 270°, 300°, 330°), and six loading velocities (10, 20, 30, 40, 50, and 60 km/h) were conducted. Criteria of effective strain, Von-Mises stress, contact force, and self-designed normalized eccentricity were used to evaluate the biomechanism of pelvic fracture. Based on our simulation results, it’s challenging to distinguish impact from run-over only rely on certain characteristic fractures. Loads on the front and back were less likely to cause pelvic fractures. In the 30°, 60°, 300° load directions, the overall deformation caused a “diagonal” pelvic fracture. The higher is the velocity (kinetic energy), the more severe is the pelvic fracture. The contact force will predict the risk of fracture. In addition, our self-designed eccentricity will distinguish the injury manner of impact and run-over under the 90° loads. The “biomechanical fingerprints” based on logistic regression of all biomechanical variables have an AUC of 0.941 in discriminating the injury manners. Our study may provide simulation evidence and new methods for the forensic community to improve the forensic identification ability of injury manners.


Materials ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 333
Author(s):  
Anna Skic ◽  
Iwona Puzio ◽  
Grzegorz Tymicki ◽  
Paweł Kołodziej ◽  
Marta Pawłowska-Olszewska ◽  
...  

The investigations on the response of bone tissue under different loading conditions are important from clinical and engineering points of view. In this paper, the influence of nesfatin-1 administration on rat humerus mechanical properties was analyzed. The classical three-point bending and impact tests were carried out for three rat bone groups: control (SHO), the humerus of animals under the conditions of established osteopenia (OVX), and bones of rats receiving nesfatin-1 after ovariectomy (NES). The experiments proved that the bone strength parameters measured under various mechanical loading conditions increased after the nesfatin-1 administration. The OVX bones were most susceptible to deformation and had the smallest fracture toughness. The SEM images of humerus fracture surface in this group showed that ovariectomized rats had a much looser bone structure compared to the SHO and NES females. Loosening of the bone structure was also confirmed by the densitometric and qualitative EDS analysis, showing a decrease in the OVX bones’ mineral content. The samples of the NES group were characterized by the largest values of maximum force obtained under both quasi-static and impact conditions. The energies absorbed during the impact and the critical energy for fracture (from the three-point bending test) were similar for the SHO and NES groups. Statistically significant differences were observed between the mean Fi max values of all analyzed sample groups. The obtained results suggest that the impact test was more sensitive than the classical quasi-static three-point bending one. Hence, Fi max could be used as a parameter to predict bone fracture toughness.


Sign in / Sign up

Export Citation Format

Share Document