Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 471
Author(s):  
Yu He ◽  
Xinhui Zhang ◽  
Wenhao Wu ◽  
Jun Zhang ◽  
Wenyuan Bai ◽  
...  

A flexible grounding system is a system in which the neutral point of the power supply is grounded via the arc suppression coil in parallel with a low-resistance resistor. When operating normally or a temporary ground fault occurs, the arc suppression coil is used for grounding, whereas the small resistance is switched on when a permanent ground fault occurs. At present, the problem of low protection sensitivity when a high-resistance ground fault occurs in a flexible grounding system has not been solved yet. According to the characteristics of low waveform similarity between the faulty line and the non-faulty line when a single-phase grounding fault occurred, a new faulty line selection method based on a combination of Dynamic Time Warping (DTW) distance and the transient projection method is proposed in this paper. Firstly, the fault transient signal is extracted by a digital filter as a basis for faulty line selection. Secondly, the transient zero-sequence current of each line is projected onto the busbar transient zero-sequence voltage, and the projected DTW distance of each line is calculated. Finally, according to the calculation formula of waveform comprehensive similarity coefficient, the Comprehensive DTW (CDTW) distance is obtained, and the top three CDTW distance values are selected to determine the faulty line. If the maximum value is greater than the sum of the other two CDTW distance values, the line corresponding to the maximum value is judged as the faulty line; otherwise, it is judged as a busbar fault. The simulation results based on MATLAB/Simulink and field data test show that the method can accurately determine the faulty line under diverse fault conditions.


2021 ◽  
Vol 2076 (1) ◽  
pp. 012095
Author(s):  
Meijie Liu ◽  
Degui Ji ◽  
Zhen Meng

Abstract In this paper, to accurately compensate the arc suppression coil, the structure of the transformer is improved. Here, a fixed inductive element is connected in series with the short-circuit winding, which combines with the leakage inductance of the original transformer to form a new short circuit impedance. The improved transformer reduces the manufacturing cost and difficulty of the controllable inductor, reduces the requirements for the winding of the reactor, and makes the manufacturing easier.


Author(s):  
Dong Fu ◽  
Yi Wang ◽  
Jinghua Zhou ◽  
Chenyang Liu ◽  
Zixuan Zhai ◽  
...  

2021 ◽  
Author(s):  
P. Vančata ◽  
I. Matuljak ◽  
X. Tomáš

2021 ◽  
Author(s):  
D. Hardman ◽  
Y. Mavrocostanti ◽  
J. Sleep ◽  
N. Murdoch