tube bundle
Recently Published Documents


TOTAL DOCUMENTS

989
(FIVE YEARS 183)

H-INDEX

30
(FIVE YEARS 5)

2022 ◽  
Vol 168 ◽  
pp. 108894
Author(s):  
Do Yun Kim ◽  
Hee Cheon NO ◽  
Byong Guk Jeon ◽  
Sang Gyu Lim ◽  
Ho Joon Yoon
Keyword(s):  

2022 ◽  
Vol 109 ◽  
pp. 103460
Author(s):  
Henri Dolfen ◽  
Jeroen De Ridder ◽  
Landon Brockmeyer ◽  
Elia Merzari ◽  
Graham Kennedy ◽  
...  

2022 ◽  
Vol 2022 ◽  
pp. 1-17
Author(s):  
Shiqin Ai ◽  
Chao Sun ◽  
Yuechan Liu ◽  
Yuelin Li

The reliability of the heat exchanger tube bundle not only affects the economic efficiency of production but also relates to the normal development of production safety and health. To study the flow-induced vibration of tube bundles, a three-dimensional finite element model of heat exchange tubes and watersheds inside and outside the tubes was established to explore the flow-induced vibration characteristics of tube bundles and analyze the natural frequencies of single-span and multispan heat exchange tubes. Considering the randomness of the effective support between the tube bundle and the support plate of the heat exchanger, the natural frequency and vibration mode of the four-span tube with failure of the tube bundle support are analyzed. On this basis, the vibration caused by the two-way coupling flow between tube and tube outflow is calculated. Finally, the flow-induced vibration characteristics of the five-tube bundle with two different pitch-diameter ratios are analyzed. The calculation results show that the error between the calculated natural frequencies and the theoretical values is less than 3%, and within the allowable error range, the natural frequencies of the same order decrease with the increase of the number of support failures. The vibration frequencies of single-span and multispan tube bundles are consistent with the lift and drag frequencies, the vibration displacement curves show typical Strouhal modes, and the amplitude increases with the increase of fluid velocity. Vibration displacement curves of symmetrical spans of multispan tube bundles are similar in shape and amplitude. With the increase of tube bundle spacing, the vibration characteristics become more obvious.


2022 ◽  
Vol 6 (1) ◽  
pp. 1
Author(s):  
Zhiwei Wu ◽  
Caifu Qian

Baffles with holes in different diameters (or HDD baffles) and conically-corrugated tubes are respectively longitudinal flow baffle and high-efficiency heat exchange tubes proposed by the author. In this paper, vibrations of tube bundles with HDD baffles and fluid flow as well as heat transfer inside conically-corrugated tubes were numerically simulated, and the heat exchanger with conically-corrugated tubes and HDD baffles was tested for the heat transfer efficiency. It is found that compared with the traditional segmental baffles, tube bundle vibrations in heat exchangers, if using the HDD baffles, can be significantly reduced. Regarding heat transfer efficiency, conically-corrugated tubes are much better than smooth tubes and even better than other high-efficiency heat transfer tubes. Compared with the traditional heat exchangers, heat exchangers constructed with conically-corrugated tubes and the HDD baffles can provide better heat transfer efficiency and less tube bundle vibration.


2022 ◽  
Vol 305 ◽  
pp. 117690
Author(s):  
Wandong Zheng ◽  
Hao Yin ◽  
Bojia Li ◽  
Huan Zhang ◽  
Jakub Jurasz ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7754
Author(s):  
Jianwen Zhang ◽  
Yahui Zhao ◽  
Yan Li ◽  
Fan Zhang

The corrosion failure of the high-pressure heat exchanger in a petrochemical enterprise was simulated. A multiphase flow and heat and mass transfer simulation shows that the vortex core with a higher gas phase content and lower temperature is the region of easy crystallization, located on both sides of the center of the tube. The crystallization process occurs in the gas phase. As the reaction progresses, the crystallization range spreads from the tube wall to the center of the tube bundle, and the inner diameter of the tube bundle decreases continuously. In Fluent, a user-defined function, based on the ammonium chloride crystallization reaction, is loaded. The results show that crystallization first occurs in the tube bundles on both sides of the center of the tube and that the corrosion is aggravated by the erosion wall surface of crystal particles at the elbow, which is consistent with the actual corrosion failure location.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7542
Author(s):  
Sebastian Gamisch ◽  
Stefan Gschwander ◽  
Stefan J. Rupitsch

Latent thermal energy storages (LTES) offer a high storage density within a narrow temperature range. Due to the typically low thermal conductivity of the applied phase change materials (PCM), the power of the storages is limited. To increase the power, an efficient heat exchanger with a large heat transfer surface and a higher thermal conductivity is needed. In this article, planar wire cloth heat exchangers are investigated to obtain these properties. They investigated the first time for LTES. Therefore, we developed a finite element method (FEM) model of the heat exchanger and validated it against the experimental characterization of a prototype LTES. As PCM, the commercially available paraffin RT35HC is used. The performance of the wire cloth is compared to tube bundle heat exchanger by a parametric study. The tube diameter, tube distance, wire diameter and heat exchanger distance were varied. In addition, aluminum and stainless steel were investigated as materials for the heat exchanger. In total, 654 variants were simulated. Compared to tube bundle heat exchanger with equal tube arrangement, the wire cloth can increase the mean thermal power by a factor of 4.20 but can also reduce the storage capacity by a minimum factor of 0.85. A Pareto frontier analysis shows that for a free arrangement of parallel tubes, the tube bundle and wire cloth heat exchanger reach similar performance and storage capacities.