Abstract Background:To evaluate Inferior vena cava (IVC) filter retrieval practices over a 9-year period at an academic hospital with a prospectively maintained IVC filter registry. Method:An IVC filter registry was maintained prospectively within our institution. We reviewed cases between August 2011 and June 2020, following filter status, retrieval plans, and eventual retrieval date. The validity of the database was cross referenced with a Picture Archiving and Communication System and patient records. Results:343 patients had IVC filters inserted. Three filter types were used, Celect (Cook Medical) in 189, Gunther Tulip (GT) (Cook Medical) in 65, ALN (ALN) in 89. 196 filters were retrieved, 108 were made permanent, 36 died before retrieval, and 3 were yet to be retrieved. Retrieval rates were 92.5% overall (86% for GT, 93% for Celect and 94.5% for ALN). The mean dwell time for successful retrieval was 59 days with the majority of insertions (85%) removed in under 100 days. Failed initial retrieval occurred in 23 patients, 10 (43%) were retrieved at second attempt, 13/23 filters remained in-situ and were deemed permanent after discussion with the patient and referring team. Conclusion:The removal of IVC filters, when indication for insertion has past, is no longer the sole responsibility of the referring physician but also the responsibility of the Interventionalist. Our retrieval rates of 92.5% of eligible IVC filters highlights the value of maintaining a prospective IVC filter registry.


Author(s):  
Micheal T. Ayad ◽  
David L. Gillespie
Keyword(s):  

2021 ◽  
Vol 34 (3) ◽  
pp. 128-134
Author(s):  
Fabricio Vassallo ◽  
Luciano Santos ◽  
Betina Reseck Walker ◽  
Rodrigo França ◽  
Christina Madeira ◽  
...  

Percutaneous procedures through femoral access in patients with inferior vena cava (IVC) filter may be at risk of complications. We evaluated the feasibility and safety of left atrial appendage closure (LAAC) through femoral access in patients previously implanted with IVC filter. We described the WatchmanTM device implantation in two patients with formal contraindication for oral anticoagulation. First patient had a GreenfieldTM filter and the second one an OpteaseTM filter, and in this patient an attempt to withdrawal the filter immediately before the LAAC procedure failed. A femoral approach was performed in both patients using a 14 Fr sheath. Before crossing IVC filters, venographies did not detect any thrombus. All steps of IVC filter crossing were performed under fluoroscopic guidance. No immediate or intrahospital complications related to the procedure occurred. Herein, we presented two cases of successful LAAC closure with Watchman device in patients with two different kinds of IVC filters.


2021 ◽  
Vol 50 (1) ◽  
pp. 201-201
Author(s):  
Vedica Sharma ◽  
Anna Prishchepova ◽  
Vinaya Sermadevi ◽  
Chakradhar Venkata ◽  
Michael Plisco
Keyword(s):  

2021 ◽  
Vol 5 ◽  
pp. 19
Author(s):  
Brice Burke ◽  
Osama Abdul-Rahim ◽  
Kendyl Burke ◽  
Zeiad Hussain

Although the use of inferior vena cava (IVC) filters has expanded, complications have led to the recommendation to remove all unnecessary filters. Several techniques exist to aid in retrieving irretrievable IVC filters. The balloon-assisted retrieval technique has previously been described to aid in cases of an embedded hook. This report describes an alternative use of the balloon-assisted technique, specifically to aid in the retrieval of Greenfield IVC filters in cases of strut perforation of the cava wall. This technique was successfully performed in six out of six attempted cases with no associated complications.


2021 ◽  
Vol 206 (Supplement 3) ◽  
Author(s):  
Aeen Asghar ◽  
David Strauss ◽  
Randall Lee ◽  
Henry Hirsch ◽  
Eric Choi ◽  
...  
Keyword(s):  

Author(s):  
Ingrid Marjolein Bistervels ◽  
Abby E. Geerlings ◽  
Peter I. Bonta ◽  
Wessel Ganzevoort ◽  
IJsbrand A.J. Zijlstra ◽  
...  

Background: Patients with an inferior vena cava (IVC) filter that remains in situ encounter a lifelong increased risk of deep vein thrombosis and IVC filter complications including fracture, perforation and IVC filter thrombotic occlusion. Data on the safety of becoming pregnant with an in situ IVC filter are scarce. Objective: To evaluate the risk of complications of in situ IVC filters during pregnancy. Methods: We performed a retrospective cohort study of pregnant patients with an in situ IVC filter from a tertiary center between 2000 and 2020. We collected data on complications of IVC filters and pregnancy outcomes. Additionally, we performed a systematic literature search in MEDLINE, Embase and grey literature. Findings: We identified seven pregnancies in four patients with in situ IVC filters with a mean time since IVC filter insertion of 3 years (range 1-8). No complications of IVC filter occurred during pregnancy. Review of literature yielded five studies including 13 pregnancies in nine patients. In one pregnancy a pre-existent, until then asymptomatic, chronic perforation of the vena cava wall by the IVC filter caused major bleeding and uterine trauma with fetal loss. Overall, the complication rate was 5%. Conclusion: It seems safe to become pregnant with an indwelling IVC filter that is intact and does not show signs of perforation, but due to the low number of cases no firm conclusions about safety of in situ IVC filters during pregnancy can be drawn. We suggest imaging prior to pregnancy to reveal asymptomatic IVC filter complications.


2021 ◽  
Vol 24 (3) ◽  
pp. E587-E588
Author(s):  
Yuhai Zhang ◽  
Ming Shen ◽  
Weimin Huang ◽  
Liang Wang ◽  
Shixiong Wei

Inferior vena cava (IVC) filters have been widely used to prevent pulmonary emboli in patients with venous thromboembolism. Here we report a rare case of complete pericardial tamponade with severe mitral and tricuspid valve regurgitation due to a fractured IVC filter. A 38-year-old male came to our emergency department with a 19-day history of progressive chest tightness. Chest x-ray revealed a tethering catheter fractured at the level of the junction of the superior vena cava and the right atrium. We performed open surgery and discovered that a steel wire had punctured the atrioventricular septum, the mitral valve, and finally the posterior wall of the left ventricle. The patient recovered quite well and was discharged after 1 week.


2021 ◽  
pp. 153857442110225
Author(s):  
Haidong Wang ◽  
Zhenhua Liu ◽  
Xiaofei Zhu ◽  
Jianlong Liu ◽  
Libo Man

Background: Inferior vena cava (IVC) filters are commonly used in China to prevent pulmonary embolisms in patients with deep vein thrombosis. However, IVC filter removal is complicated when the filter has penetrated the IVC wall and endovascular techniques usually fail. The purpose of this study was to evaluate the effectiveness and safety of retroperitoneal laparoscopic-assisted retrieval of wall-penetrating IVC filters after endovascular techniques have failed. Patients and Methods: We retrospectively evaluated a series of 8 patients who underwent retroperitoneal laparoscopic-assisted retrieval of a wall-penetrating IVC filter between December 2017 and November 2019. All patients had experienced at least 1 failure with endovascular retrieval before the study. The filters were slanted and the proximal retrieval hooks penetrated the posterior lateral IVC wall in all patients on computed tomography. Demographic information, operation parameters, and complications were recorded and analyzed. All patients were followed up for at least 12 months. Results: The procedure was successful in all patients. The median surgery time was 53.6 ± 12.7 min and the average blood loss was 45.0 ± 13.5 ml. No serious complication occurred during the patients’ hospitalization, which was an average of 6.4 days. The median follow-up time was 15.1 months, and no patient had deep vein thrombosis recurrence. Conclusions: Retroperitoneal laparoscopic-assisted retrieval is a feasible and effective technique, particularly when proximal retrieval hooks penetrate the posterior lateral wall of the IVC after endovascular techniques have failed. To some extent, the development of this technique at our institution has increased the success rate of filter removal and improved patient satisfaction.


2021 ◽  
Vol 39 ◽  
Author(s):  
Pasquale Grillo ◽  
◽  
Giuseppe Granata ◽  
Anna Savoldi ◽  
Giovanni Rodà ◽  
...  

Caval filters are placed in the inferior vena cava (IVC) to prevent pulmonary thromboembolism in patients with deep vein thrombosis. If there is no indication for thrombo-embolic risk prevention, the filter can be removed to reduce potential filter-related complications. Advanced endovascular techniques are frequently used to retrieve IVC filters. We describe an alternative filter-removal technique for use when standard techniques are not practicable. In our method, the filter hook is embedded within the IVC wall. To retrieve it, a long introducer is inserted; a guidewire and the "loop snare" retrieval system are then advanced through it with a coaxial system and positioned below the filter at the level of the common iliac vein confluence. The guidewire is then passed through the loop, creating a "sling" around the filter which allows the application of traction from the bottom upwards, releasing the hook from the wall. The loop is then held under tension with the filter aligned in the IVC lumen, and the introducer is advanced distally to completely cover the filter, allowing complete retrieval of the filter without damaging the vessel walls. This modified Sling technique is a safe and feasible method for complicated IVC filter retrieval.