test kit
Recently Published Documents


TOTAL DOCUMENTS

1332
(FIVE YEARS 486)

H-INDEX

39
(FIVE YEARS 9)

2022 ◽  
Author(s):  
Qiao Wang ◽  
Lili Feng ◽  
Haohai Zhang ◽  
Juehua Gao ◽  
Changchuin Mao ◽  
...  

Abstract While mRNA vaccines against SARS-CoV-2 were highly efficacious against severe illness and hospitalization, they seem to be less effective in preventing infection months after vaccination, especially with the Delta variant. Breakthrough infections might be due to higher infectivity of the variants, relaxed protective measures by the general public in “COVID-19 fatigue”, and/or waning immunity post-vaccination. Determining the neutralizing antibody levels in a longitudinal manner may address this issue, but technical complexity of classic assays precludes easy detection and quick answers. We developed a lateral flow immunoassay NeutraXpress™ (commercial name of the test kit by Antagen Diagnostics, Inc.), and tested fingertip blood samples of subjects receiving either Moderna or Pfizer vaccines at various time points. With this device, we confirmed the reported clinical findings that mRNA vaccine-induced neutralizing antibodies quickly wane after 3–6 months. Thus, using rapid tests to monitor neutralizing antibody status could help identify individuals at risk, prevent breakthrough infections and guide social behavior to curtail the spread of COVID-19. Statement of Significance. Mounting evidence suggests that mRNA vaccine-induced neutralizing antibody titres against SARS-CoV-2 wane in 3–6 months. Quick identification of fully vaccinated persons with high risk of breakthrough infections is key to control the COVID-19 pandemic. The described LFIA device having a control/sample dual-lane design serves this purpose with successful field-test data.


PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0262174
Author(s):  
Valentina Tonelotto ◽  
Annamaria Davini ◽  
Laura Cardarelli ◽  
Milena Calderone ◽  
Paola Marin

Objectives The aim of this study was to evaluate the clinical performance of the Fluorecare SARS-CoV-2 Spike Protein Test Kit, a rapid immunochromatographic assay for SARS-CoV-2 detection. Moreover, we sought to point out the strategy adopted by a local company to lift the lockdown without leading to an increase in the number of COVID-19 cases, by performing a precise and timely health surveillance. Methods The rapid Fluorecare SARS-CoV-2 Spike Protein Test was performed immediately after sampling following the manufacturer’s instructions. RT-PCRs were performed within 24 hours of specimen collection. A total amount of 253 nasopharyngeal samples from 121 individuals were collected between March 16 and April 2, 2021 and tested. Results Of 253 nasopharyngeal samples, 11 (9.1%) were positive and 242 (90.9%) were negative for SARS-CoV-2 RNA by RT-PCR assays. The rapid SARS-CoV-2 antigen detection test’s mean sensitivity and specificity were 84,6% (95% CI, 54.6–98.1%) and 100% (95% CI, 98.6–100%), respectively. Two false negative test results were obtained from samples with high RT-PCR cycle threshold (Ct). Conclusion Our study suggested that Fluorecare SARS-CoV-2 Spike Protein Test can be introduced into daily diagnostic practice, as its mean sensitivity and specificity follow the standards recommended by WHO and IFCC Task Force. In addition, we underlined how the strategy adopted by a local company to risk assessment and health surveillance was appropriate for infection containment. This real-life scenario gave us the possibility to experience potential approaches aimed to preserve public health and work activities.


Animals ◽  
2022 ◽  
Vol 12 (2) ◽  
pp. 167
Author(s):  
Maria Mößler ◽  
Kathrin Rychli ◽  
Volker Reichmann ◽  
Thiemo Albert ◽  
Thomas Wittek

Colostrum provides the newborn with nutrients and immunoglobulins. Immunoglobulins and their intestinal transfer play a major role in the immune system of neonates since they are born agammaglobulinemic. In this study immunoglobulin G (IgG) content was determined in alpaca colostrum and the correlations of the IgG concentration by fat, protein, lactose and minerals were calculated. Colostrum samples were collected daily from 20 multiparous alpaca mares during the first four days after parturition. The IgG concentrations were determined by radial immunodiffusion using a Camelid IgG Test Kit. The IgG concentration decreased significantly from 26,319 mg/dL on day 1 to 3848.8 mg/dL on day 4. There were significant correlations between IgG concentration and the other components of the colostrum. While the correlations between IgG and fat (r = −0.69, p ≤ 0.001) and lactose (r = −0.64, p ≤ 0.001) were negative, the correlations with protein (r = 0.91, p ≤ 0.001), magnesium (r = 0.86, p ≤ 0.001) and cobalt (r = 0.87, p ≤ 0.001) were strongly positive. Due to the strong association, the colostrum protein concentration could be used for a brief estimation of the IgG content.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Xuexiang Lin ◽  
Xiao-Yu Liu ◽  
Bo Zhang ◽  
Ai-Qing Qin ◽  
Kwok-Min Hui ◽  
...  

AbstractCurrent methods used for diagnosis of acute infection of pathogens rely on detection of nucleic acids, antigens, or certain classes of antibodies such as IgM. Here we report a virus enzyme assay as an alternative to these methods for detection of acute viral infection. In this method, we used a luciferin derivative as the substrate for detection of the enzyme activity of influenza viral neuraminidase as a means for diagnosis of influenza. The resulting commercial test, the qFLU Dx Test, uses a different supply chain that does not compete with those for the current tests. The assay reagents were formulated as a master mix that accommodated both the neuraminidase and luciferase reactions, thereby enabling rapid and prolonged production of stable light signal in the presence of influenza virus in the sample. The assay was evaluated using depository throat swab specimens. As expected, the assay exhibited similar detection rates for all influenza types and subtypes except for A(H7N9), which exhibited lower detection rate due to lower viral titer in the specimens. When throat swab specimens were diluted with the sample buffer of the test kit and tested with the qFLU Dx Test. The sensitivity and specificity were 82.41% (95% confidence interval: 79.66–85.84%) and 95.39% (95% confidence interval: 94.32–96.46%), respectively, for these diluted specimens in comparison to a real-time polymerase chain reaction assay. The uniqueness of the qFLU Dx Test as an enzymatic assay makes it highly complementary with currently available methods.


PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0262312
Author(s):  
Lawrence Henry Ofosu-Appiah ◽  
Dodzi Kofi Amelor ◽  
Bright Ayensu ◽  
Ernest Akyereko ◽  
Nafisah Issah Rabiwu ◽  
...  

Yellow fever is endemic in Ghana and outbreaks occur periodically. The prodromal signs due to Yellow Fever Virus (YFV) infection are non-specific, making clinical signs unreliable as the sole criteria for diagnosis. Accurate laboratory confirmation of suspected yellow fever cases is therefore vital in surveillance programs. Reporting of ELISA IgM testing results by laboratories can delay due to late arrival of samples from the collection sites as well as limited availability of ELISA kits. In this study, the diagnostic performance characteristics of a rapid immunochromatographic Standard Q Yellow Fever IgM test kit (SD Biosensor) was evaluated for the rapid diagnosis of Yellow Fever infection in Ghana. A panel of 275 sera, comprising 81 confirmed YFV positives and 194 negatives were re-tested in this study using the Standard Q Yellow Fever IgM test kit. Using the CDC/WHO Yellow Fever IgM capture ELISA as a benchmark, the sensitivity, specificity and accuracy of the Standard Q Yellow Fever test kit were 96.3%, 97.9% and 97.5%, respectively. The false positivity rate was 5.1% and there was no cross-reactivity when the Standard Q Yellow Fever test kit was tested against dengue, malaria and hepatitis B and C positive samples. In addition, inter-reader variability and invalid rate were both zero. The results indicate that the diagnostic performance of the Standard Q Yellow Fever IgM test kit on serum or plasma is comparable to the serum IgM detection by ELISA and can be used as a point of care rapid diagnostic test kit for YFV infection in endemic areas.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Adekemi Sekoni ◽  
Waimar Tun ◽  
Osasuyi Dirisu ◽  
Temitope Ladi-Akinyemi ◽  
Elizabeth Shoyemi ◽  
...  

Abstract Background Self-care health interventions are innovative approaches for improving health and achieving the sustainable development goals (SDGs). Men who have sex with men (MSM) have been disproportionately affected by Human Immunodeficiency Virus (HIV). In spite of this, stigma from healthcare workers has reportedly prevented MSM from accessing HIV testing in health facilities. This paper explored the operationalization of using key opinion leaders (KOLs) to distribute HIVST (HIV self-test) kits to MSM. This qualitative survey used a combination of in-depth interviews (IDI) with HIVST users and focus group discussions (FGDs) with KOLs to collect data three months after the distribution of the test kits by the KOLs. Thematic analysis of the data was carried out. Result Three themes were generated namely: KOLs serve as a trusted resource to promote and support HIVST for the MSM community; Skills and qualifications required for KOLs to effectively distribute and promote uptake of HIVST; and Effective strategies used to create demand and promote uptake of HIVST. Conclusion This study showed the practical steps involved in operationalizing KOL support system distribution of HIVST that positively influenced the testing experience for the participants irrespective of the HIV status and engagement in care. KOLs are a reliable resource to leverage for ensuring that HIV self-test kit is utilized and HIV positive individuals are linked to treatment and care in homophobic environments.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 136
Author(s):  
Nitaya Indrawattana ◽  
Pisinee Aiumurai ◽  
Nawannaporn Sae-lim ◽  
Watee Seesuay ◽  
Onrapak Reamtong ◽  
...  

A point-of-care diagnostic for early and rapid diagnosis of scrub typhus caused by Orientia tsutsugamushi is required for prompt and proper treatment of patients presenting with undifferentiated febrile illnesses. In this study, an immunochromatographic antigen detection test kit (ICT AgTK) that targets the highly conserved O. tsutsugamushi 60 kDa GroEL chaperonin (heat shock protein 60) was developed. E. coli-derived recombinant GroEL expressed from DNA coding for the consensus sequence of 32 GroEL gene sequences extracted from the GenBank database was used to immunize rabbits and mice. Rabbit polyclonal antibodies (pAb) were used for preparing a gold-pAb conjugate, and the rGroEL-specific mouse monoclonal antibody was used as the antigen detection reagent at the ICT test line. In-house validation revealed that the ICT AgTK gave 85, 100 and 95% diagnostic sensitivity, specificity and accuracy, respectively, compared to the combined clinical features and standard IFA when tested on 40 frozen serum samples. The test kits correctly identified 10 scrub typhus samples out of 15 fresh plasma/buffy coat samples of patients with febrile illnesses. For independent laboratory validation, the ICT AgTK was sent to one provincial hospital. The ICT AgTK utilized by the hospital medical technologist correctly identified six scrub typhus samples out of 20 serum samples of patients with fever, as confirmed by specific IgM/IgG detection by IFA. The ICT AgTK is easy to perform with rapid turn-around time. It has the potential to be used as an important tool for on-site and early scrub typhus diagnosis by allowing testing of freshly collected samples (serum, plasma or buffy coat), especially in resource-limited healthcare settings.


Jurnal Elemen ◽  
2022 ◽  
Vol 8 (1) ◽  
pp. 16-28
Author(s):  
Nursakiah Nursakiah ◽  
Fathrul Arriah ◽  
Surya Dharma

Various studies on the development of mathematical literacy tests have not shown any research that focuses on developing mathematical literacy tests using the context of Bugis-Makassar local wisdom with Classical Test Theory (CTT). Thus, this study aimed to produce mathematical literacy tests using the context of Bugis-Makassar local wisdom based on CTT for junior high school students through development research using ADDIE design. The development of the test integrates mathematical literacy and local wisdom elements of Bugis-Makassar. There were 15 multiple-choice items developed and tested on 33 males and 68 females at seventh-grade junior high school students. The trial involved two schools in Makassar City using a convenience sampling technique. The test kit was validated by three mathematicians and produced an Aiken index score in the range of 0.67 to 0.89. The empirical data from the trial results were analyzed using CTT assisted by ITEMAN 4.3 software. The test analysis showed an average category for reliability test scores. As many as 47% of the items were in the medium category, and the rest were in the fair category. Meanwhile, 93% of the items have a good discriminatory ability, and 67% have distractors that were not functioning properly, then the tests items must be revised.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Yueting Tang ◽  
Jiayu Sun ◽  
Yumeng Yuan ◽  
Fen Yao ◽  
Bokun Zheng ◽  
...  

Abstract Background Serosurveillance is crucial in estimating the range of SARS-CoV-2 infections, predicting the possibility of another wave, and deciding on a vaccination strategy. To understand the herd immunity after the COVID-19 pandemic, the seroprevalence was measured in 3062 individuals with or without COVID-19 from the clinic. Methods The levels of SARS-CoV-2 antibody IgM and IgG were measured by the immuno-colloidal gold method. A fusion fragment of nucleocapsid and spike protein was detected by a qualitative test kit with sensitivity (89%) and specificity (98%). Results The seroprevalence rate for IgM and IgG in all outpatients was 2.81% and 7.51%, respectively. The sex-related prevalence rate of IgG was significantly higher (P < 0.05) in women than men. The highest positive rate of IgM was observed in individuals < 20 years of age (3.57%), while the highest seroprevalence for IgG was observed in persons > 60 years of age (8.61%). Positive rates of IgM and IgG in the convalescent patients were 31.82% and 77.27%, respectively, which was significantly higher than individuals with suspected syndromes or individuals without any clinical signs (P < 0.01). Seroprevalence for IgG in medical staff was markedly higher than those in residents. No significant difference of seroprevalence was found among patients with different comorbidities (P > 0.05). Conclusions The low positive rate of the SARS-CoV-2 IgM and nucleic acid (NA) test indicated that the SARS-CoV-2 outbreak is subsiding after 3 months, and the possibility of reintroduction of the virus from an unidentified natural reservoir is low. Seroprevalence provides information for humoral immunity and vaccine in the future.


2022 ◽  
pp. 131351
Author(s):  
Nutthaporn Malahom ◽  
Purim Jarujamrus ◽  
Wipark Anutrasakda ◽  
Atitaya Siripinyanond ◽  
Maliwan Amatatongchai ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document