biomechanical forces
Recently Published Documents


TOTAL DOCUMENTS

123
(FIVE YEARS 42)

H-INDEX

20
(FIVE YEARS 4)

2022 ◽  
Vol 20 (1) ◽  
Author(s):  
Ehteramolsadat Hosseini ◽  
Amin Solouki ◽  
Masood Haghshenas ◽  
Mehran Ghasemzadeh ◽  
Simone M. Schoenwaelder

Abstract Background Continuous agitation during storage slows down the platelet storage lesions. However, in special circumstances, manual-mixing can be alternatively used to store products for short time periods without compromising platelet quality. Based on this finding, and given the role of shear stress in modulating receptor expression, we were interested in comparing the levels of platelet adhesion receptor, GPVI and platelet adhesion capacity under each storage condition. Methods Platelet concentrates (PCs) were divided into three groups: continuously-agitated PCs (CAG-PCs) with or without PP2 (Src kinase inhibitor) and manually-mixed PCs (MM-PCs). Platelet count/MPV, swirling, GPVI and P-selectin expression, GPVI shedding, platelet adhesion/spreading to collagen were examined during 5 days of storage. Results While MM- and CAG-PCs showed similar levels of P-selectin expression, GPVI expression was significantly elevated in MM-PCs with lower GPVI shedding/expression ratios, enhanced platelet adhesion/spreading and swirling in manually-mixed PCs. Of note, CAG-PCs treated with PP2 also demonstrated lower P-selectin expression and GPVI shedding, higher GPVI expression and attenuated swirling and spreading capability. Conclusion Given the comparable platelet activation state in MM and CAG-PCs as indicated by P-selectin expression, enhanced platelet adhesion/spreading in MM-PCs, along with relatively higher GPVI expression here, supports previous studies demonstrating a role for biomechanical forces in modulating GPVI-dependent function. Thus, lower GPVI expression in CAG-PCs may be due to shear forces induced by agitation, which keeps this receptor down-regulated while also attenuating platelet adhesion/spreading capacities during storage. Low platelet function in PP2-CAG-PCs also highlights the importance of Src-kinases threshold activity in maintaining platelets quality.


2022 ◽  
Vol 8 ◽  
Author(s):  
Bronte Miller ◽  
Mary Kathryn Sewell-Loftin

The endothelial cells that compose the vascular system in the body display a wide range of mechanotransductive behaviors and responses to biomechanical stimuli, which act in concert to control overall blood vessel structure and function. Such mechanosensitive activities allow blood vessels to constrict, dilate, grow, or remodel as needed during development as well as normal physiological functions, and the same processes can be dysregulated in various disease states. Mechanotransduction represents cellular responses to mechanical forces, translating such factors into chemical or electrical signals which alter the activation of various cell signaling pathways. Understanding how biomechanical forces drive vascular growth in healthy and diseased tissues could create new therapeutic strategies that would either enhance or halt these processes to assist with treatments of different diseases. In the cardiovascular system, new blood vessel formation from preexisting vasculature, in a process known as angiogenesis, is driven by vascular endothelial growth factor (VEGF) binding to VEGF receptor 2 (VEGFR-2) which promotes blood vessel development. However, physical forces such as shear stress, matrix stiffness, and interstitial flow are also major drivers and effectors of angiogenesis, and new research suggests that mechanical forces may regulate VEGFR-2 phosphorylation. In fact, VEGFR-2 activation has been linked to known mechanobiological agents including ERK/MAPK, c-Src, Rho/ROCK, and YAP/TAZ. In vascular disease states, endothelial cells can be subjected to altered mechanical stimuli which affect the pathways that control angiogenesis. Both normalizing and arresting angiogenesis associated with tumor growth have been strategies for anti-cancer treatments. In the field of regenerative medicine, harnessing biomechanical regulation of angiogenesis could enhance vascularization strategies for treating a variety of cardiovascular diseases, including ischemia or permit development of novel tissue engineering scaffolds. This review will focus on the impact of VEGFR-2 mechanosignaling in endothelial cells (ECs) and its interaction with other mechanotransductive pathways, as well as presenting a discussion on the relationship between VEGFR-2 activation and biomechanical forces in the extracellular matrix (ECM) that can help treat diseases with dysfunctional vascular growth.


Biomedicines ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 1856
Author(s):  
Kristina Andelovic ◽  
Patrick Winter ◽  
Thomas Kampf ◽  
Anton Xu ◽  
Peter Michael Jakob ◽  
...  

Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe−/−, n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.


Author(s):  
Sandrine Morel ◽  
Philippe Bijlenga ◽  
Brenda R. Kwak

Abstract Intracranial aneurysm (IA), a local outpouching of cerebral arteries, is present in 3 to 5% of the population. Once formed, an IA can remain stable, grow, or rupture. Determining the evolution of IAs is almost impossible. Rupture of an IA leads to subarachnoid hemorrhage and affects mostly young people with heavy consequences in terms of death, disabilities, and socioeconomic burden. Even if the large majority of IAs will never rupture, it is critical to determine which IA might be at risk of rupture. IA (in)stability is dependent on the composition of its wall and on its ability to repair. The biology of the IA wall is complex and not completely understood. Nowadays, the risk of rupture of an IA is estimated in clinics by using scores based on the characteristics of the IA itself and on the anamnesis of the patient. Classification and prediction using these scores are not satisfying and decisions whether a patient should be observed or treated need to be better informed by more reliable biomarkers. In the present review, the effects of known risk factors for rupture, as well as the effects of biomechanical forces on the IA wall composition, will be summarized. Moreover, recent advances in high-resolution vessel wall magnetic resonance imaging, which are promising tools to discriminate between stable and unstable IAs, will be described. Common data elements recently defined to improve IA disease knowledge and disease management will be presented. Finally, recent findings in genetics will be introduced and future directions in the field of IA will be exposed.


Author(s):  
Claire Lamaison ◽  
Simon Latour ◽  
Nelson Hélaine ◽  
Valérie Le Morvan ◽  
Julien Saint-Vanne ◽  
...  

Non-Hodgkin B-cell lymphomas (B-NHL) mainly develop within lymph nodes (LN) as densely packed aggregates of tumor cells and their surrounding microenvironment, creating a tumor niche specific to each lymphoma subtypes. In vitro preclinical models mimicking biomechanical forces, cellular microenvironment, and 3D organization of B-cell lymphomas remain scarce, while all these parameters constitute key determinants of lymphomagenesis and drug resistance. Using a microfluidic method based on cell encapsulation inside permeable, elastic, and hollow alginate microspheres, we developed a new tunable 3D-model incorporating lymphoma B cells, extracellular matrix (ECM), and/or tonsil stromal cells (TSC). We revealed that under 3D confinement lymphoma B cells were able to form cohesive spheroids resulting from overexpression of ECM components. Moreover, lymphoma B cells and TSC dynamically formed self-organized 3D spheroids favoring spheroid growth. 3D culture induced resistance to classical chemotherapeutic agent doxorubicin, but not to BCL2 inhibitor ABT-199, identifying this approach as a relevant in vitro model to assess the activity of therapeutic agents in B-NHL. RNAseq analysis highlighted the synergy of 3D, ECM, and TSC in upregulating similar pathways in malignant B cells in vitro than those overexpressed in primary lymphoma cells in situ. Finally, our 3D model including ECM and TSC allowed long-term in vitro survival of primary follicular lymphoma B cells. In conclusion, we propose a new high throughput 3D model mimicking lymphoma tumor niche and making it possible to study the dynamic relationship between lymphoma B cells and their microenvironment and to screen new anti-cancer drugs.


Author(s):  
Shukurov Sherzod Shuxratovich ◽  
◽  
Turaev Alimjan Baxriddinovich ◽  
Arziqulova Munisa Shuxratovna ◽  
Makhmudov Gulomjon Alisherovich ◽  
...  

Success or failure of implants depends on the health of the person receiving the treatment, drugs which affect the chances of Osseo integration, and the health of the tissues in the mouth. The amount of stress that will be put on the implant and fixture during normal function is also evaluated. Planning the position and number of implants is key to the long-term health of the prosthetic since biomechanical forces created during chewing can be significant.


Author(s):  
Chad M. Hobson ◽  
Jesse S. Aaron ◽  
John M. Heddleston ◽  
Teng-Leong Chew

The importance of mechanical force in biology is evident across diverse length scales, ranging from tissue morphogenesis during embryo development to mechanotransduction across single adhesion proteins at the cell surface. Consequently, many force measurement techniques rely on optical microscopy to measure forces being applied by cells on their environment, to visualize specimen deformations due to external forces, or even to directly apply a physical perturbation to the sample via photoablation or optogenetic tools. Recent developments in advanced microscopy offer improved approaches to enhance spatiotemporal resolution, imaging depth, and sample viability. These advances can be coupled with already existing force measurement methods to improve sensitivity, duration and speed, amongst other parameters. However, gaining access to advanced microscopy instrumentation and the expertise necessary to extract meaningful insights from these techniques is an unavoidable hurdle. In this Live Cell Imaging special issue Review, we survey common microscopy-based force measurement techniques and examine how they can be bolstered by emerging microscopy methods. We further explore challenges related to the accompanying data analysis in biomechanical studies and discuss the various resources available to tackle the global issue of technology dissemination, an important avenue for biologists to gain access to pre-commercial instruments that can be leveraged for biomechanical studies.


2021 ◽  
Author(s):  
Sybille Koehler ◽  
Barry Denholm

Podocytes are highly specialized epithelial cells of the kidney glomerulus and are an essential part of the filtration barrier. Due to their position and function in the kidney, they are exposed to constant biomechanical forces such as shear stress and hydrostatic pressure. These forces increase during disease, resulting in podocyte injury and loss. The mechanism by which biomechanical forces are sensed and transduced to elicit an adaptive and protective response remains largely unknown. Here we show, using the Drosophila nephrocyte model, that the mechanosensor Cheerio (dFilamin) is central to this mechano-protective mechanism. We found expression of an activated mechanosensitive variant of Cheerio induced hypertrophy and rescued filtration function in injured nephrocytes. Additional analysis with human Filamin B confirmed this mechano-protective role. We delineated the mechano-protective pathway downstream of Cheerio and found activation of TOR and Yorkie induce nephrocyte hypertrophy, whereas their repression reversed the Cheerio-mediated hypertrophy. Although Cheerio/Filamin B pathway mediates a mechano-protective role in the face of injury, we found excessive activity resulted in a pathological phenotype, indicating activity levels must be tightly controlled. Taken together, our data suggest that Cheerio acts via the TOR and YAP pathway to induce hypertrophic growth, as a mechano-protective response to nephrocyte injury.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ji-Hun Kang ◽  
Hyun Joo Lee ◽  
Ok-Hyeon Kim ◽  
Yong Ju Yun ◽  
Young-Jin Seo ◽  
...  

AbstractMechanical forces are pervasive in the inflammatory site where dendritic cells (DCs) are activated to migrate into draining lymph nodes. For example, fluid shear stress modulates the movement patterns of DCs, including directness and forward migration indices (FMIs), without chemokine effects. However, little is known about the effects of biomechanical forces on the activation of DCs. Accordingly, here we fabricated a microfluidics system to assess how biomechanical forces affect the migration and activity of DCs during inflammation. Based on the structure of edema, we proposed and experimentally analyzed a novel concept for a microchip model that mimicked such vascular architecture. The intensity of shear stress generated in our engineered chip was found as 0.2–0.6 dyne/cm2 by computational simulation; this value corresponded to inflammation in tissues. In this platform, the directness and FMIs of DCs were significantly increased, whereas the migration velocity of DCs was not altered by shear stress, indicating that mechanical stimuli influenced DC migration. Moreover, DCs with shear stress showed increased expression of the DC activation markers MHC class I and CD86 compared with DCs under static conditions. Taken together, these data suggest that the biomechanical forces are important to regulate the migration and activity of DCs.


Author(s):  
Adrian Cavalcanti Kußmaul ◽  
Fanny Schwaabe ◽  
Manuel Kistler ◽  
Clara Gennen ◽  
Sebastian Andreß ◽  
...  

Abstract Introduction Open book fractures are challenging injuries oftentimes requiring surgical treatment. The current treatment of choice is symphyseal plating, which requires extensive surgery and entirely limits physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a semi-rigid implant (modified SpeedBridge™) as a minimally invasive tape suture construct for the treatment of open book fractures and evaluated the superiority of two techniques of implementation: criss-cross vs. triangle technique. Materials and methods Nine synthetic symphyseal joints were dissected creating an open book fracture. The different osteosynthesis methods (plating, modified SpeedBridge™ in criss-cross/triangle technique) were then applied. All constructs underwent horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, dislocation (mm) and stiffness (N/mm) were calculated. Results Symphyseal plating for the treatment of open book fractures proved to be a rigid osteosynthesis significantly limiting the physiological mobility of the symphyseal joint (dislocation: 0.08 ± 0.01 mm) compared to the tape sutures (dislocation: triangle technique 0.27 ± 0.07 mm, criss-cross technique 0.23 ± 0.05 mm) regarding horizontal tension (p < 0.01). Both modified SpeedBridge™ techniques showed sufficient biomechanical stability without one being superior to the other (p > 0.05 in all directions). Considering vertical loading, no statistical difference was found between all osteosynthesis methods (caudal: p = 0.41; cranial: p = 0.61). Conclusions Symphyseal plating proved to be the osteosynthesis method with the highest rigidity. The modified SpeedBridge™ as a semi-rigid suture construct provided statistically sufficient biomechanical stability while maintaining a minimum of symphyseal movement, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis. Furthermore, both the criss-cross and the triangle technique displayed significant biomechanical stability without one method being superior.


Sign in / Sign up

Export Citation Format

Share Document